Katie Powell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Katie Powell has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad Amer
Agile Kinetic, Newport NP20 1GL, UK
2 shared publications - Caomhnad O’flaherty Farrell
School of Engineering, Cardiff University, Cardiff CF10 3AT, UK
2 shared publications - Catherine A. Holt
Biomechanics & Bioengineering Centre Versus Arthritis, Cardiff University, Cardiff, United Kingdom; Cardiff School of Engineering, College of Physical Sciences and Engineering, Cardiff University, Cardiff, United Kingdom
2 shared publications - Jenny Williams
School of Engineering, Cardiff University, Cardiff CF10 3AT, UK
2 shared publications - Peter Bishop
Agile Kinetic, Newport NP20 1GL, UK
2 shared publications - Zornitza Glavcheva
School of Engineering, Cardiff University, Cardiff CF10 3AT, UK
2 shared publications
Latest Publications
- Open Access
MoveLab®: Validation and Development of Novel Cross-Platform Gait and Mobility Assessments Using Gold Standard Motion Capture and Clinical Standard Assessment
Wearable health assessment devices enable real-time clinical- and home-based patient monitoring. Human gait analysis is a widely accepted musculoskeletal assessment. The 30 s Sit-to-Stand (STS) and Timed-Up-and-Go (TUG) are clinical frailty assessments used alongside gait analysis. This study assessed the reliability and validity of the MoveLab® (Agile Kinetic 2024) approach to measure gait spatiotemporal parameters (STPs), STS, and TUG using a waist-worn mobile phone, compared to the Gold Standard 3D marker-based motion capture (Qualisys AB, Sweden) and the Clinical Standard assessment of the STS and TUG test methods. Movement data, recorded simultaneously for 25 healthy volunteers (14 female and 11 male, Age = 31.8 ± 11.6 yrs) in a Biomechanics Laboratory using the Gold Standard system, the Clinical Standard assessments, and MoveLab®, was analyzed using Intraclass Correlation (ICC) and Bland–Altman plots (Python) to quantify the correlations, consistency, and significance across the output parameters. Comparing the methods, the STP consistency ranged from acceptable to good for all the tested parameters (ICC 0.299–0.894). The highest and lowest correlations were cycle time and terminal double support time, respectively. The TUG showed good agreement (ICC 0.757). Generally, an equal number of MoveLab® STS repetitions were observed. MoveLab® demonstrated validity and reliability for a range of key movement parameters using a pouch-worn mobile phone device in healthy adults in a controlled laboratory environment.
Open AccessMoveLab®: Validation and Development of Novel Cross-Platform Gait and Mobility Assessments Using Gold Standard Motion Capture and Clinical Standard Assessment
Wearable health assessment devices enable real-time clinical- and home-based patient monitoring. Human gait analysis is a widely accepted musculoskeletal assessment. The 30 s Sit-to-Stand (STS) and Timed-Up-and-Go (TUG) are clinical frailty assessments used alongside gait analysis. This study assessed the reliability and validity of the MoveLab® (Agile Kinetic 2024) approach to measure gait spatiotemporal parameters (STPs), STS, and TUG using a waist-worn mobile phone, compared to the Gold Standard 3D marker-based motion capture (Qualisys AB, Sweden) and the Clinical Standard assessment of the STS and TUG test methods. Movement data, recorded simultaneously for 25 healthy volunteers (14 female and 11 male, Age = 31.8 ± 11.6 yrs) in a Biomechanics Laboratory using the Gold Standard system, the Clinical Standard assessments, and MoveLab®, was analyzed using Intraclass Correlation (ICC) and Bland–Altman plots (Python) to quantify the correlations, consistency, and significance across the output parameters. Comparing the methods, the STP consistency ranged from acceptable to good for all the tested parameters (ICC 0.299–0.894). The highest and lowest correlations were cycle time and terminal double support time, respectively. The TUG showed good agreement (ICC 0.757). Generally, an equal number of MoveLab® STS repetitions were observed. MoveLab® demonstrated validity and reliability for a range of key movement parameters using a pouch-worn mobile phone device in healthy adults in a controlled laboratory environment.
- Open Access
- 2 July 2025
- Published by MDPI AG in Preprints.org
MoveLab®: Validation and Development of Novel Cross-Platform Gait and Mobility Assessments using Gold Standard Systems
Wearable health assessment devices enable real-time clinical- and home-based patient monitoring. Human gait analysis is a widely accepted musculoskeletal assessment. 30-second-Sit-to-Stand (STS) and Timed-up-and-Go (TUG) are clinical frailty assessments used alongside gait. This study assessed the reliability and validity of the MoveLab® (Agile Kinetic 2024) approach to measure gait spatiotemporal parameters (STPs), STS and TUG using a waist-worn mobile phone, compared to ‘gold standard’ 3D marker-based motion capture (Qualisys AB, Sweden). Movement data, recorded simultaneously, for 25 healthy volunteers in a Biomechanics Laboratory, using the gold standard system and MoveLab®, was analysed using Intraclass Correlation (ICC), and Bland-Altman plots (Python), to quantify correlations, consistency, and significance across output parameters. Comparing the methods, STP consistency ranged from acceptable to excellent for all tested parameters (ICC 0.299–0.9). Highest and lowest correlations were cycle time and terminal double support time, respectively. TUG showed good agreement (ICC 0.757). Generally, an equal number of MoveLab® STS repetitions were observed. MoveLab® was shown to demonstrate validity and reliability when measuring movement parameters using a pouch-worn mobile phone device in healthy adults in a controlled laboratory environment.
- 2 July 2025
- Published by MDPI AG in Preprints.org
Open AccessMoveLab®: Validation and Development of Novel Cross-Platform Gait and Mobility Assessments using Gold Standard Systems
Wearable health assessment devices enable real-time clinical- and home-based patient monitoring. Human gait analysis is a widely accepted musculoskeletal assessment. 30-second-Sit-to-Stand (STS) and Timed-up-and-Go (TUG) are clinical frailty assessments used alongside gait. This study assessed the reliability and validity of the MoveLab® (Agile Kinetic 2024) approach to measure gait spatiotemporal parameters (STPs), STS and TUG using a waist-worn mobile phone, compared to ‘gold standard’ 3D marker-based motion capture (Qualisys AB, Sweden). Movement data, recorded simultaneously, for 25 healthy volunteers in a Biomechanics Laboratory, using the gold standard system and MoveLab®, was analysed using Intraclass Correlation (ICC), and Bland-Altman plots (Python), to quantify correlations, consistency, and significance across output parameters. Comparing the methods, STP consistency ranged from acceptable to excellent for all tested parameters (ICC 0.299–0.9). Highest and lowest correlations were cycle time and terminal double support time, respectively. TUG showed good agreement (ICC 0.757). Generally, an equal number of MoveLab® STS repetitions were observed. MoveLab® was shown to demonstrate validity and reliability when measuring movement parameters using a pouch-worn mobile phone device in healthy adults in a controlled laboratory environment.