Junbo Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Junbo Peng has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Chih-Wei Chang
Emory University
1 shared publication David S Yu
Radiation Oncology, Emory University School of Medicine, 1365 Clifton Rd NE Building C, Atlanta, Georgia, 30303-3073, UNITED STATES
1 shared publicationHuiqiao Xie
Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, New York, 10065, UNITED STATES
1 shared publicationJustin Roper
Department of Radiology and Sciences Imaging Department of Radiology Oncology, Emory University, 100 Woodruff Circle, Atlanta, Georgia, 30322-1007, UNITED STATES
1 shared publication- Richard Lei Jingyi Qiu
Department of Radiation Oncology and Winship Cancer Institute Emory University Atlanta Georgia USA
1 shared publication Tonghe Wang
Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, New York, 10065, UNITED STATES
1 shared publication
Latest Publications
- Open Access
- 11 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (14) , 145010
Optimization-based image reconstruction regularized with inter-spectral structural similarity for limited-angle dual-energy cone-beam CT
Objective. Limited-angle dual-energy (DE) cone-beam CT (CBCT) is considered as a potential solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, its clinical implementations are hindered by the challenging image reconstruction from limited-angle projections. While optimization-based and deep learning-based methods have been proposed for image reconstruction, their utilization is limited by the requirement for x-ray spectra measurement or paired datasets for model training. This work aims to facilitate the clinical applications of fast and low-dose DE-CBCT by developing a practical solution for image reconstruction in limited-angle DE-CBCT. Approach. An inter-spectral structural similarity-based regularization was integrated into the iterative image reconstruction in limited-angle DE-CBCT. By enforcing the similarity between the DE images, limited-angle artifacts were efficiently reduced in the reconstructed DECBCT images. The proposed method was evaluated using two physical phantoms and three digital phantoms, demonstrating its efficacy in quantitative DECBCT imaging. Main results. In all the studies, the proposed method achieves accurate image reconstruction without visible residual artifacts from limited-angle DE-CBCT projection data. In the digital phantom studies, the proposed method reduces the mean-absolute-error from 309/290 HU to 14/20 HU, increases the peak signal-to-noise ratio from 40/39 dB to 70/67 dB, and improves the structural similarity index measurement from 0.74/0.72–1.00/1.00. Significance. The proposed method can efficiently reduce limited-angle artifacts during the image reconstruction, enabling quantitative DE-CBCT with comparable data acquisition time and radiation dose to that of a single-energy scan on current onboard scanners without hardware modification. This work is of great clinical significance and can boost the clinical application of DE-CBCT in image-guided radiation therapy and surgical interventions.
- 11 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (14) , 145010
Open AccessOptimization-based image reconstruction regularized with inter-spectral structural similarity for limited-angle dual-energy cone-beam CT
Objective. Limited-angle dual-energy (DE) cone-beam CT (CBCT) is considered as a potential solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, its clinical implementations are hindered by the challenging image reconstruction from limited-angle projections. While optimization-based and deep learning-based methods have been proposed for image reconstruction, their utilization is limited by the requirement for x-ray spectra measurement or paired datasets for model training. This work aims to facilitate the clinical applications of fast and low-dose DE-CBCT by developing a practical solution for image reconstruction in limited-angle DE-CBCT. Approach. An inter-spectral structural similarity-based regularization was integrated into the iterative image reconstruction in limited-angle DE-CBCT. By enforcing the similarity between the DE images, limited-angle artifacts were efficiently reduced in the reconstructed DECBCT images. The proposed method was evaluated using two physical phantoms and three digital phantoms, demonstrating its efficacy in quantitative DECBCT imaging. Main results. In all the studies, the proposed method achieves accurate image reconstruction without visible residual artifacts from limited-angle DE-CBCT projection data. In the digital phantom studies, the proposed method reduces the mean-absolute-error from 309/290 HU to 14/20 HU, increases the peak signal-to-noise ratio from 40/39 dB to 70/67 dB, and improves the structural similarity index measurement from 0.74/0.72–1.00/1.00. Significance. The proposed method can efficiently reduce limited-angle artifacts during the image reconstruction, enabling quantitative DE-CBCT with comparable data acquisition time and radiation dose to that of a single-energy scan on current onboard scanners without hardware modification. This work is of great clinical significance and can boost the clinical application of DE-CBCT in image-guided radiation therapy and surgical interventions.