Taeyun Ku
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Taeyun Ku has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Joon-Goon Kim
Affiliation Graduate School of Medical Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea
2 shared publicationsAriel J. Lee
Department of Physics, Korea Advanced Institute of Science and Technology (KAIST)
1 shared publicationDae-Hyeon Song
Affiliation Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea
1 shared publicationHerve Hugonnet
Department of Physics, Korea Advanced Institute of Science and Technology (KAIST)
1 shared publicationHoyeon Nam
Affiliation Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea
1 shared publicationHyejin Shin
Affiliation Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 3 July 2025
- Published by Public Library of Science (PLoS) in PLOS Biology
- Vol. 23 (7) , e3003240
Highly accurate image registration for 3D multiplexed cyclic imaging using dense labeling in expandable tissue gels
Multiplexed cyclic imaging in expandable tissue gels has been extensively studied to visualize numerous biomolecules at a nanoscale resolution in situ. Previous studies have employed sparse labels, such as DAPI or lectin staining, as registration markers. However, these sparse labels do not adequately capture the full extent of deformation across the entire region of interest. To overcome this challenge, we propose the use of dense labels, specifically fluorophore N-hydroxysuccinimide (NHS)-ester staining, as registration markers to achieve highly accurate image registration. We first tested several NHS-functionalized fluorophores as fiducial markers and identified the proper candidates for three-dimensional (3D) multiplexed cyclic imaging. We analyzed the registration accuracy between DAPI and NHS-ester staining and illustrated that dense label-based registration provides a more accurate registration performance. In the multiplexed imaging of expanded specimens, we observed that repetitive expansion/shrinking processes and chemical treatments for signal elimination can induce 3D nonlinear distortion. This sample distortion can be mitigated by re-embedding the tissue gel or replacing the chemical de-staining process with photobleaching-based signal removal or computational signal unmixing. With such an optimized experimental setup, we demonstrated 3D multiplexed cyclic imaging with nanoscale precision image registration. Finally, we prove that dense biological structures, such as actin, can be used as registration markers to achieve high registration accuracy. We anticipate that the proposed dense labeling strategy will overcome the technical limitations of multiplexed cyclic imaging in expandable tissue gels, offering high-precision registration. We expect it to be widely adopted by the biological and medical communities.
- 3 July 2025
- Published by Public Library of Science (PLoS) in PLOS Biology
- Vol. 23 (7) , e3003240
Open AccessHighly accurate image registration for 3D multiplexed cyclic imaging using dense labeling in expandable tissue gels
Multiplexed cyclic imaging in expandable tissue gels has been extensively studied to visualize numerous biomolecules at a nanoscale resolution in situ. Previous studies have employed sparse labels, such as DAPI or lectin staining, as registration markers. However, these sparse labels do not adequately capture the full extent of deformation across the entire region of interest. To overcome this challenge, we propose the use of dense labels, specifically fluorophore N-hydroxysuccinimide (NHS)-ester staining, as registration markers to achieve highly accurate image registration. We first tested several NHS-functionalized fluorophores as fiducial markers and identified the proper candidates for three-dimensional (3D) multiplexed cyclic imaging. We analyzed the registration accuracy between DAPI and NHS-ester staining and illustrated that dense label-based registration provides a more accurate registration performance. In the multiplexed imaging of expanded specimens, we observed that repetitive expansion/shrinking processes and chemical treatments for signal elimination can induce 3D nonlinear distortion. This sample distortion can be mitigated by re-embedding the tissue gel or replacing the chemical de-staining process with photobleaching-based signal removal or computational signal unmixing. With such an optimized experimental setup, we demonstrated 3D multiplexed cyclic imaging with nanoscale precision image registration. Finally, we prove that dense biological structures, such as actin, can be used as registration markers to achieve high registration accuracy. We anticipate that the proposed dense labeling strategy will overcome the technical limitations of multiplexed cyclic imaging in expandable tissue gels, offering high-precision registration. We expect it to be widely adopted by the biological and medical communities.
- Open Access
Volumetric refractive index measurement and quantitative density analysis of mouse brain tissue with sub-micrometer spatial resolution
High-resolution structural imaging of brain tissue is important for neuroscience research. However, conventional approaches have several limitations, such as the need for exogenous staining, limited accessibility to volumetric information, and qualitative analysis. Herein, we present high-resolution label-free volumetric imaging and analysis of mouse brain tissue using three-dimensional quantitative phase imaging. Measurement of the refractive index distribution of tissue enables direct imaging of the cellular and subcellular structures. Quantification of subcellular organelles is performed in the anatomical regions of the somatosensory cortex, corpus callosum, caudoputamen, and thalamus regions.
Open AccessVolumetric refractive index measurement and quantitative density analysis of mouse brain tissue with sub-micrometer spatial resolution
High-resolution structural imaging of brain tissue is important for neuroscience research. However, conventional approaches have several limitations, such as the need for exogenous staining, limited accessibility to volumetric information, and qualitative analysis. Herein, we present high-resolution label-free volumetric imaging and analysis of mouse brain tissue using three-dimensional quantitative phase imaging. Measurement of the refractive index distribution of tissue enables direct imaging of the cellular and subcellular structures. Quantification of subcellular organelles is performed in the anatomical regions of the somatosensory cortex, corpus callosum, caudoputamen, and thalamus regions.