MDMichael J. DiPirro

Michael J. DiPirro

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael J. DiPirro has a total of 401 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design and performance of the Hitomi/XRISM adiabatic demagnetization refrigerator controller

    by Meng P. Chiao, Thomas G. Bialas, Knute A. Ray, Michael J. DiPirro, Caroline A. Kilbourne, Frederick S. Porter, Peter J. Shirron, Gary A. Sneiderman

    The Resolve instrument1 is a collaboration between Japan Aerospace Exploration Agency (JAXA) and National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC), with contributions from Space Research Organization Netherlands and European Space Agency. Details on the XRISM mission can be found in Tashiro et.al.,2 and on the Resolve instrument in Ishisaki et al.1 In summary, NASA provided the Calorimeter Spectrometer Insert (CSI), which includes the detector subsystem (DS), the 3-stage ADR, and the high Tc superconductor subsystem (HTS), as well as the aperture assembly (ApA, including filters), the ADRC, the X-ray Box1 (XBOX, for processing and digitizing analog detector signals), the X-ray mirror assembly (XMA), and XMA harnesses. The CSI and ApA are integrated in a dewar provided by JAXA’s contractor Sumitomo Heavy Industries, whereas the ADRC is approximately a meter away from the dewar center, as can be seen in Fig. 1. (This view of the representative locations is not available after the instrument integration with the spacecraft.)

  • Open Access

    Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

    by Richard L. Kelley, Yoshitaka Ishisaki, Elisa Costantini, Hisamitsu Awaki, Jesus C. Balleza, Kim R. Barnstable, Thomas G. Bialas, Rozenn Boissay-Malaquin, Gregory V. Brown, Edgar R. Canavan, et al.

    We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.


  • Open Access

    Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

    by Yoshitomo Maeda, Ryuichi Fujimoto, Hisamitsu Awaki, Jesus C. Balleza, Kim R. Barnstable, Thomas G. Bialas, Rozenn Boissay-Malaquin, Gregory V. Brown, Edgar R. Canavan, Timothy M. Carnahan, et al.

    The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.


  • Top Cited Papers
    Open Access

    Resolve instrument onboard XRISM: design, integration, and instrument test results

    by Yoshitaka Ishisaki, Richard L. Kelley, Hisamitsu Awaki, Jesus C. Balleza, Kim R. Barnstable, Thomas G. Bialas, Rozenn Boissay-Malaquin, Gregory V. Brown, Edgar R. Canavan, Renata S. Cumbee, et al.

    The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6×6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm2 at 1 keV and 424 cm2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.


  • Open Access

    On-orbit performance of the adiabatic demagnetization refrigerator on XRISM

    by Peter J. Shirron, Mark O. Kimball, Richard S. Ottens, Bryan L. James, Edgar R. Canavan, Michael J. DiPirro, Thomas A. Bialas, Gary A. Sneiderman, Caroline A. Kilbourne, Frederick S. Porter, et al.

    The Resolve instrument1 on the X-ray Imaging and Spectroscopy Mission (XRISM) observatory2 is a high-resolution imaging spectrometer designed to measure the energy of individual photons in the soft X-ray band (0.2 to 13 keV). It is essentially a rebuild of the soft X-ray spectrometer instrument3 on Hitomi, consisting of a 6×6 array of microcalorimeters located at the focal point of a grazing-incidence X-ray telescope.4 Its extraordinary energy resolution of less than 5 eV is achieved in part by operating the array at 50 mK using a three-stage ADR.5 As on Hitomi, the cryogenic system6 consists of a 40-L tank of superfluid helium (at <1.3  K), a 4.5 K Joule–Thomson (JT) cryocooler, and two-stage Stirling cryocoolers7,8 used to cool vapor-cooled shields and provide pre-cooling for the JT stage.


  • Open Access

    Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

    by Kosuke Sato, Yoshitaka Ishisaki, Richard L. Kelley, Hisamitsu Awaki, Jesus C. Balleza, Kim R. Barnstable, Thomas G. Bialas, Rozenn Boissay-Malaquin, Gregory V. Brown, Edgar R. Canavan, et al.

    The X-Ray Imaging and Spectroscopy Mission (XRISM) was launched at 23:42, September 6 (Universal Time: UT), 2023, from JAXA’s Tanegashima Space Center (TNSC). It was developed through an international collaboration among Japanese, United States, and European institutions.1 The Resolve instrument onboard XRISM is composed of an X-ray microcalorimeter spectrometer and an X-ray mirror assembly (XMA). The microcalorimeter has a detector array of 6×6  pixels and is designed to achieve an energy resolution of 7 eV at full width at half maximum (FWHM) at 6 keV, operating at 50 mK. Combined with the XMA, Resolve covers a 3′×3′ field of view with an angular resolution of 1.7′ or better half power diameter (HPD).2,3 The design of the Resolve instrument is almost identical to the soft X-ray spectrometer (SXS) onboard ASTRO-H.4 The detector array is cooled to 50 mK with a two-stage adiabatic demagnetization refrigerator (ADR) controlled by an ADR controller (ADRC), and its heat sink is cooled using pumped superfluid liquid helium (LHe).5 The LHe tank is shielded by a He4 Joule–Thomson (JT) cryocooler and multiple two-stage Stirling cycle (2ST) cryocoolers to reduce the heat load on the LHe tank. Two sets of 2STs are used for each of the shield coolers (SC: SCA and SCB) and for the pre-coolers (PC: PCA and PCB) of the JT (see Sato et al.5 for details). The lifetime requirement for a nominal operation with 30 L LHe is >3 years. Even if the LHe is depleted, the Resolve instrument is designed to continue operating using the third ADR stage that is heat sunk to the JT. To maximize the amount of LHe in flight, the He tank is filled with superfluid LHe before launch. Due to pre-launch operational constraints, we need to periodically turn off the cryocoolers and/or the LHe evacuation pumps. This means that the LHe temperature rises, and the available amount of LHe in orbit decreases. If the temperature rise is too large, there is a risk that the LHe would transition from superfluid to normal liquid after launch, resulting in a loss of LHe through the porous plug phase separator that retains the LHe in the He tank while venting boil-off gas.6 Therefore, careful planning and operations are needed for the pre-launch LHe top-off and cooldown and the post-launch cryocooler start-up.

  • Open Access

    PRIMA mission concept

    by Jason Glenn, Margaret Meixner, Charles M. Bradford, Klaus Pontoppidan, Alexandra Pope, Tiffany Kataria, Jennifer Rocca, Elizabeth Luthman, Lee Armus, Jochem Baselmans, et al.

    In Pathways to Discovery in Astronomy and Astrophysics for the 2020s1 (hereinafter Astro2020), the Astronomical Decadal Survey recommended a new class of space observatories: astrophysics Probes. The scale of the Probes fills the gap between MIDEXs on the smaller side (e.g., SPHEREx for a recent example2) and Flagship Missions (e.g., JWST3 and HWO4). NASA responded with a call for concept proposals for X-ray and far-infrared (far-IR) Probes that were due in November 2023. With a $1.5 billion cost cap, Probes can accomplish more ambitious science than MIDEXs and launch more frequently than Flagship missions—perhaps one per decade. This higher cadence than Flagships (which have 2+ decade development and implementation phases) and intermediate scale enables NASA both to take advantage of maturing technologies and to have Explorer-like principal investigator (PI) science and community-driven general observer (GO) and guest investigator (GI) science programs. Indeed, the APEX Announcement of Opportunity mandated that at least 70% of observing time be reserved for GO science and that all PI science data be made available rapidly for GI science. The PI-managed cost cap for Probes is $1.0 billion, with $500 million reserved for the launch vehicle and services (∼$150 million) and administration (by NASA) of competed GO and GI science (∼$350 million).


  • Continuous adiabatic demagnetization refrigerator for the PRobe far-infrared mission for astrophysics (PRIMA)

    by Michael DiPirro, Peter Shirron, Mark Kimball, Richard Ottens, Edgar Canavan, Weibo Chen, Brad Moore

    The PRobe far-Infrared Mission for Astrophysics (PRIMA) contains two instruments: an imager (PRIMAGER) and a multiband spectrometer (FIRESS). These two instruments require detector cooling to 100 mK and require parts of the optical train to operate at 1.0 K. From a base temperature of 4.5 K, provided by a JWST-like cryocooler, a five-stage Continuous Adiabatic Demagnetization Refrigerator (CADR) will provide this cooling to both instruments. The PRIMA CADR is based on heritage parts from the Hitomi and the X-Ray Imaging and Spectroscopy Mission ADRs and from recent Strategic Astrophysics Technology–developed hardware. The CADR will provide 700 μW of lift at 1.0 K and 13 μW of lift at 120 mK to meet the two instruments’ (PRIMAger and FIRESS) cooling requirements with a factor of 2 margin. The CADR is designed to reject a maximum of 10 mW at the 4.5 K cryocooler heat sink. We will describe the CADR, its requirements, its operation, and its heritage.

  • Open Access

    Line emission mapper microcalorimeter spectrometer

    by Simon R. Bandler, Joseph S. Adams, Edward G. Amatucci, Edgar R. Canavan, James A. Chervenak, Renata S. Cumbee, Johannes P. D. Dercksen, Michael J. DiPirro, William B. Doriese, Megan E. Eckart, et al.

    The line emission mapper (LEM) is a probe-class mission concept that is designed to detect x-ray emission lines from hot ionized gas (T > 106 K) that will enable us to test galaxy evolution theories. It will permit us to study the effects of stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. The key to being able to study the hot gases that are otherwise invisible to current imaging x-ray spectrometers is that the energy resolution is sufficient to use cosmological redshift to separate extragalactic source lines from foreground Milky Way emission. LEM incorporates a large-format microcalorimeter array instrument called the LEM microcalorimeter spectrometer (LMS) with a light-weight x-ray optic with 10” half power diameter angular resolution. The LMS microcalorimeter array has pixels with 15″ pixel pitch over a 33′ field of view (FOV) optimized for the 0.3 to 2 keV energy band. The central 7′ region of the array has an energy resolution of 1.3 eV at 1 keV and the rest of the FOV has 2.5 eV energy resolution at 1 keV. The array will be read out with state-of-the-art time-division multiplexing. We present an overview of the LMS instrument, including details of the entire detection chain, the focal plane assembly, as well as the cooling system and overall mechanical and thermal design. For each of the key technologies, we discuss the current technology readiness level and the plan to advance them to be ready for flight. We also describe the current system design and our estimate for the mass, power, and data rate of the instrument. The design details presented concentrate primarily on the unique aspects of the LMS design compared with prior missions and confirm that the type of microcalorimeter instrument needed for LEM is not only feasible but also technically mature.


  • Open Access

    Heterodyne Receiver for Origins

    by Martina C. Wiedner, Susanne Aalto, Edward G. Amatucci, Andrey M. Baryshev, Victor Y. Belitsky, Asantha Cooray, Elvire De Beck, Yan Delorme, Brian N. Ellison, Martin J. Eggens, et al.

    The Origins Space Telescope (Origins)1 – 4 traces our cosmic history, from the formation of the first galaxies and the rise of metals to the development of habitable worlds and present-day life. Origins does this through exquisite sensitivity to infrared radiation from ions, atoms, dust, and molecules especially water in the form of vapor and ice. Origins observes extra-solar planetary atmospheres, protoplanetary disks, and large-area extragalactic fields in the wavelength range of 2.8 to 588  μm and is more than 1000 times more sensitive than its predecessors due to its large, cold (4.5 K) telescope and advanced instruments.