N. Ismail
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
N. Ismail has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Aleksandra Vatian
School of Translational Information Technologies, ITMO University, 197101 St. Petersburg, Russia
2 shared publications - Alexey Zubanenko
ITMO UniversityITMO University
2 shared publications - Natalia Gusarova
ITMO University
2 shared publications - A. D. Beresnev
ITMO University
1 shared publication - Alexander Golubev
ITMO University
1 shared publication - Almaz G. Vanyurkin
Almazov National Medical Research Center
1 shared publication
Latest Publications
- 23 December 2025
- Published by ITMO University in Scientific and Technical Journal of Information Technologies, Mechanics and Optics
- Vol. 25 (6)
Transformer-based automated coronary artery segmentation with domain-specific pretraining
Automated segmentation of coronary arteries in coronary computed tomography angiography plays an important role in the diagnosis and treatment of coronary artery disease. Manual segmentation of coronary arteries requires significant labor costs and is accompanied by subjective errors, which necessitates the development of accurate and reliable automated methods for coronary artery segmentation. The paper presents an approach based on a deep neural network with the Swin-UNETR architecture which combines the advantages of visual transformers and the U-Net structure. To improve the accuracy, a domain-specific transfer learning strategy was used: the model was pre-trained on the ImageCAS dataset, and then further trained on a specialized dataset created for Automated Segmentation of Coronary Arteries (ASOCA) Challenge with expert labeling of coronary arteries. The accuracy of the model was assessed on 10 test Computed Tomography Coronary Angiography cases from the ASOCA dataset. The average Dice coefficient was 0.8778, and the average 95 th percentile Hausdorff distance (HD95) was 11.66 mm. The obtained results demonstrate that the accuracy of the proposed method is at the level of the leading models presented in the official ASOCA Challenge rating and exceeds the average inter-rater labeling. The proposed method provides high accuracy of coronary artery segmentation. In the future, the introduction of post-processing methods such as connected component filtering or vessel tracking, and spatial attention mechanisms can improve the accuracy of arterial contour localization and the adaptability of the model to various types of computed tomography data.
- 23 December 2025
- Published by ITMO University in Scientific and Technical Journal of Information Technologies, Mechanics and Optics
- Vol. 25 (6)
Transformer-based automated coronary artery segmentation with domain-specific pretraining
Automated segmentation of coronary arteries in coronary computed tomography angiography plays an important role in the diagnosis and treatment of coronary artery disease. Manual segmentation of coronary arteries requires significant labor costs and is accompanied by subjective errors, which necessitates the development of accurate and reliable automated methods for coronary artery segmentation. The paper presents an approach based on a deep neural network with the Swin-UNETR architecture which combines the advantages of visual transformers and the U-Net structure. To improve the accuracy, a domain-specific transfer learning strategy was used: the model was pre-trained on the ImageCAS dataset, and then further trained on a specialized dataset created for Automated Segmentation of Coronary Arteries (ASOCA) Challenge with expert labeling of coronary arteries. The accuracy of the model was assessed on 10 test Computed Tomography Coronary Angiography cases from the ASOCA dataset. The average Dice coefficient was 0.8778, and the average 95 th percentile Hausdorff distance (HD95) was 11.66 mm. The obtained results demonstrate that the accuracy of the proposed method is at the level of the leading models presented in the official ASOCA Challenge rating and exceeds the average inter-rater labeling. The proposed method provides high accuracy of coronary artery segmentation. In the future, the introduction of post-processing methods such as connected component filtering or vessel tracking, and spatial attention mechanisms can improve the accuracy of arterial contour localization and the adaptability of the model to various types of computed tomography data.
- Open Access
- 3 July 2025
- Published by ITMO University in Scientific and Technical Journal of Information Technologies, Mechanics and Optics
- Vol. 25 (3) , 457-465
Deep learning-enhanced contour interpolation techniques for 3D carotid vessel wall segmentation
When studying human vessels using the contour interpolation method, there is a problem of insufficient data for training neural networks for automatic segmentation of the carotid artery wall. In this paper, automated methods of contour interpolation are proposed to expand the datasets, which allows for improved segmentation of vessel walls and atherosclerotic plaques. In this study, the performance of various interpolation methods is compared with the traditional nearest neighboring technique. A theoretical description and comparative evaluation of Linear, Polar, and Spline interpolation are presented. Quantitative metrics, including the Dice Similarity Coefficient, area and index differences, and normalized Hausdorff distances, are used to evaluate the performance of the methods. Performance evaluations are performed on various vessel morphologies for both the lumen and the outer wall boundaries. The study showed that Linear interpolation achieves better geometric performance (Cohen’s Kappa 0.92) and improved neural network performance (Score 0.86) compared to the State-of-the-Art model. The proposed interpolation methods consistently outperform nearest neighbor interpolation. Polar and spline methods are effective in generating anatomically plausible contours with improved smoothness and continuity, eliminating transition artifacts between slices. Statistical analysis confirmed good agreement and reduced variation of these methods. The results of the study are useful for the development of automated tools for assessing atherosclerotic plaque in carotid arteries, which is important for stroke prevention. Implementation of improved interpolation methods into clinical imaging workflows can significantly improve the reliability, accuracy, and clinical utility of vessel wall segmentation.
- 3 July 2025
- Published by ITMO University in Scientific and Technical Journal of Information Technologies, Mechanics and Optics
- Vol. 25 (3) , 457-465
Open AccessDeep learning-enhanced contour interpolation techniques for 3D carotid vessel wall segmentation
When studying human vessels using the contour interpolation method, there is a problem of insufficient data for training neural networks for automatic segmentation of the carotid artery wall. In this paper, automated methods of contour interpolation are proposed to expand the datasets, which allows for improved segmentation of vessel walls and atherosclerotic plaques. In this study, the performance of various interpolation methods is compared with the traditional nearest neighboring technique. A theoretical description and comparative evaluation of Linear, Polar, and Spline interpolation are presented. Quantitative metrics, including the Dice Similarity Coefficient, area and index differences, and normalized Hausdorff distances, are used to evaluate the performance of the methods. Performance evaluations are performed on various vessel morphologies for both the lumen and the outer wall boundaries. The study showed that Linear interpolation achieves better geometric performance (Cohen’s Kappa 0.92) and improved neural network performance (Score 0.86) compared to the State-of-the-Art model. The proposed interpolation methods consistently outperform nearest neighbor interpolation. Polar and spline methods are effective in generating anatomically plausible contours with improved smoothness and continuity, eliminating transition artifacts between slices. Statistical analysis confirmed good agreement and reduced variation of these methods. The results of the study are useful for the development of automated tools for assessing atherosclerotic plaque in carotid arteries, which is important for stroke prevention. Implementation of improved interpolation methods into clinical imaging workflows can significantly improve the reliability, accuracy, and clinical utility of vessel wall segmentation.