Benjamin Weppner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Benjamin Weppner has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Alexandra Grace Roberts
Department of Radiology, Weill Cornell Medical College, New York, New York, USA
2 shared publications - Dominick Romano
Cornell University
2 shared publications - Ilhami Kovanlikaya
Department of Radiology, Weill Cornell Medical College, New York, New York, USA
2 shared publications - Mert Şişman
Department of Radiology, Weill Cornell Medical College, New York, New York, USA
2 shared publications - Pascal Spincemaille
Department of Radiology, Weill Cornell Medical College, New York, New York, USA
2 shared publications - Qihao Zhang
Department of Radiology Weill Cornell Medical College New York New York USA
2 shared publications
Latest Publications
- Open Access
Improving Glioblastoma Classification Using Quantitative Transport Mapping with a Synthetic Data Trained Deep Neural Network
Purpose: To develop a deep neural network-based, AIF-free, perfusion estimation method (QTMnet) for improved performance on glioma classification. Methods: A globally defined arterial input function (AIF) is needed to recover perfusion parameters in the two-compartment exchange model (2CXM). We have developed Quantitative Transport Mapping (QTM) to create an AIF-independent estimation method. QTM estimation can be formulated using deep neural networks trained on synthetic DCE-MRI data (QTMnet). Here, we provide a fluid mechanics-based DCE-MRI simulation with exchange between the capillaries and extravascular extracellular space. We implemented tumor ROI generation to morphologically characterize tissue perfusion. We compared our QTMnet implementation with 2CXM on 30 glioma human subjects, 15 of which had low-grade gliomas, and 15 with high-grade glioblastomas. Results: QTMnet outperforms (best AUC: 0.973) traditional 2CXM (best AUC: 0.911) in a glioma grading task. Conclusion: The AIF-independent QTMnet estimation provides a quantitative delineation between low-grade and high-grade gliomas.
Open AccessImproving Glioblastoma Classification Using Quantitative Transport Mapping with a Synthetic Data Trained Deep Neural Network
Purpose: To develop a deep neural network-based, AIF-free, perfusion estimation method (QTMnet) for improved performance on glioma classification. Methods: A globally defined arterial input function (AIF) is needed to recover perfusion parameters in the two-compartment exchange model (2CXM). We have developed Quantitative Transport Mapping (QTM) to create an AIF-independent estimation method. QTM estimation can be formulated using deep neural networks trained on synthetic DCE-MRI data (QTMnet). Here, we provide a fluid mechanics-based DCE-MRI simulation with exchange between the capillaries and extravascular extracellular space. We implemented tumor ROI generation to morphologically characterize tissue perfusion. We compared our QTMnet implementation with 2CXM on 30 glioma human subjects, 15 of which had low-grade gliomas, and 15 with high-grade glioblastomas. Results: QTMnet outperforms (best AUC: 0.973) traditional 2CXM (best AUC: 0.911) in a glioma grading task. Conclusion: The AIF-independent QTMnet estimation provides a quantitative delineation between low-grade and high-grade gliomas.
- 28 June 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (4) , 1779-1792
Validation of quantitative transport mapping (QTM) with an ex vivo perfused liver model
Purpose: To evaluate the accuracy of a deep learning–based quantitative transport mapping method (QTMnet) for measuring total tissue perfusion. Methods: QTMnet obtains tissue perfusion parametric maps from dynamic contrast‐enhanced MRI images by training on simulated data. This data uses synthetic arterial and venous vasculature geometries with flow based on constrained constructive optimization. Gadolinium contrast agent distribution is governed by the transport‐forward problem, allowing us to generate a synthetic concentration spacetime profile for a given flow, blood volume fraction, and boundary condition. Tissue flows determined by QTMnet were compared to those obtained with traditional perfusion quantification (Kety equation with Tofts generalization), which uses a global arterial input function. Their total flow accuracies were validated on explanted porcine livers that were connected to an MR compatible flow pump with specified total flow rate for dynamic contrast‐enhanced MRI experiments. Results: The mean total flow error for QTMnet was −0.34% ± 16.21% with range [−24.79%, 23.96%], compared to −35.74% ± 36.30% [−77.28%, 29.87%] for the Kety method. QTMnet provides 72% lower mean absolute error than the Kety method (12.15% vs. 43.21%, a 3.6‐fold reduction). Conclusion: The fluid mechanics‐based QTMnet accurately estimates total tissue flow in liver explants.
- 28 June 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (4) , 1779-1792
Validation of quantitative transport mapping (QTM) with an ex vivo perfused liver model
Purpose: To evaluate the accuracy of a deep learning–based quantitative transport mapping method (QTMnet) for measuring total tissue perfusion. Methods: QTMnet obtains tissue perfusion parametric maps from dynamic contrast‐enhanced MRI images by training on simulated data. This data uses synthetic arterial and venous vasculature geometries with flow based on constrained constructive optimization. Gadolinium contrast agent distribution is governed by the transport‐forward problem, allowing us to generate a synthetic concentration spacetime profile for a given flow, blood volume fraction, and boundary condition. Tissue flows determined by QTMnet were compared to those obtained with traditional perfusion quantification (Kety equation with Tofts generalization), which uses a global arterial input function. Their total flow accuracies were validated on explanted porcine livers that were connected to an MR compatible flow pump with specified total flow rate for dynamic contrast‐enhanced MRI experiments. Results: The mean total flow error for QTMnet was −0.34% ± 16.21% with range [−24.79%, 23.96%], compared to −35.74% ± 36.30% [−77.28%, 29.87%] for the Kety method. QTMnet provides 72% lower mean absolute error than the Kety method (12.15% vs. 43.21%, a 3.6‐fold reduction). Conclusion: The fluid mechanics‐based QTMnet accurately estimates total tissue flow in liver explants.