MAMustafa Tarkan Aksozen

Mustafa Tarkan Aksozen

*This is an algorithmically generated author record based on publicly available information.

Mustafa Tarkan Aksozen has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • DOSIMETRIC ANALYSIS OF DEEP INSPIRATION BREATH HOLD TECHNIQUE ADAPTED TO TANGENTIAL-BASED VOLUMETRIC MODULATED ARC THERAPY FOR LEFT BREAST CANCER AFTER MASTECTOMY

    by Dicle Aslan, Mustafa Tarkan Aksozen

    Purpose: To evaluate the dosimetric properties of the deep inspiration breath hold (DIBH) technique adapted to tangential-based volumetric modulated arc therapy (TVMAT) in left breast cancer patients with mastectomy. Method: Forty-three patients who underwent mastectomy and received chest wall and regional lymph node irradiation were included in the study. Simulation computed tomography (CT) was performed in DIBH and free-breathing (FB). Two plans were created for each patient; DIBH-TVMAT and FB-TVMAT. Both plans were realized using a mono-isocentric technique with two partial arc rotations, and the same gantry angles were used.The standard fractionation schedule for each patient was set to 50 Gy in 25 fractions. Paired-sample T-test was used to evaluate the dosimetric parameters. Results: The comparison between FB-TVMAT and DIBH-TVMAT plans revealed mean heart doses of 8.9 Gy and 5.4 Gy, respectively (p=0.000). A 6.2% reduction was encountered in left lung volume receiving 5 Gy (V5) in the DIBH-TVMAT plan (p=0.01). A reduction of 1.3 Gy at a percentage of 28% was monitored in the mean dose of the right lung in DIBH-TVMAT (p=0.000). The mean right breast dose was 0.7 Gy lower in DIBH-TVMAT (p=0.000). Conclusion: The results support that the adaptation of DIBH to TVMAT allows an optimal target volume dose coverage as well as leads to significant dose reductions in the left lung, right lung, heart, LADCA, and right breast for the left breast cancer patients with mastectomy.

  • Open Access

    Dosimetric comparison of IMRT, VMAT, and hybrid techniques in stereotactic body radiotherapy for adrenal metastases

    by Dicle Aslan, Mustafa Tarkan Aksozen

    Stereotactic body radiotherapy (SBRT) has emerged as a non-invasive alternative for the treatment of adrenal metastases, increasingly replacing traditional invasive approaches. However, its clinical application remains under investigation. The introduction of advanced radiotherapy techniques has further fueled interest in SBRT, necessitating comprehensive dosimetric evaluations to optimize treatment strategies. This study compares three distinct SBRT techniques: pure intensity-modulated radiotherapy (IMRT), pure volumetric modulated arc therapy (VMAT), and a hybrid approach combining VMAT and IMRT, utilizing flattening filter-free (FFF) photon beams. Treatment plans were assessed using dosimetric distributions, dose-volume histograms (DVH), homogeneity index (HI), and conformity index (CI). Repeated-measures analysis of variance (ANOVA) was performed, with statistical significance set at p < 0.05. Both VMAT and hybrid plans demonstrated superior CI and HI values compared to IMRT. However, the maximum dose (Dmax) to the planning target volume (PTV) was lower in the hybrid plan than in VMAT but comparable to IMRT. Additionally, critical organ dose analyses revealed that VMAT and hybrid plans achieved significantly lower doses in the renal cortex (Dmax and V17.5), duodenum (Dmax and V12.5), aorta (Dmax), and stomach (Dmax) compared to IMRT. The findings indicate that both VMAT and hybrid techniques outperform IMRT, offering improved plan quality and superior critical organ sparing. These results highlight the potential clinical advantages of VMAT and hybrid SBRT approaches in the treatment of adrenal metastases. Further clinical validation through large-scale studies is warranted to establish the optimal treatment strategy.