Sue Ping Chew
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sue Ping Chew has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Anis Shahida N. Mokhtar
Department of Electrical and Electronics Engineering, Faculty of Engineering, National Defence University of Malaysia, Kuala Lumpur, Malaysia
1 shared publication Danial Haikal Mohd Razali
Department of Electrical and Electronics Engineering, Faculty of Engineering, National Defence University of Malaysia, Kuala Lumpur, 57000, Malaysia
1 shared publicationHarry Ramza
Department of Electrical Engineering, Faculty of Industrial Technology and Informatics, Universitas Muhammadiyah Prof. Dr. HAMKA, Jakarta, 13420, Indonesia
1 shared publicationJ. Y. Teoh
Department of Electrical and Electronics Engineering, Faculty of Engineering, National Defence University of Malaysia, Kuala Lumpur, Malaysia
1 shared publication- Kin Yuen Leong
Universiti Pertahanan Nasional Malaysia
1 shared publication Latifah Sarah Supian
1 shared publication
Latest Publications
- Open Access
- 2 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 53572-53580
FPGA-Driven Thermal Management System for Photovoltaic Modules
This study discusses the design of a photovoltaic (PV) panel thermal management system driven by Field-Programmable Gate Array (FPGA). The efficiency of PV panels is often linked to their surface temperature. Since the increase in temperature on the surface of PV panels can hinder their efficiency, an effective thermal management system is needed to curb this problem. Therefore, a real-time cooling system has been designed by using an Altera DE-2 115 FPGA board integrated with K-type thermocouples and a solenoid valve to help regulate surface temperature and optimize PV panel efficiency. This system uses rainwater as the coolant to reduce panel temperature. This flow is controlled by a solenoid valve where this valve will automatically open when panel surface temperature reaches to 45 °C and will close again when the surface temperature has cooled down to 35 °C. The opening and closing of this solenoid valve are controlled by signals prompted by the FPGA board. The FPGA uses temperature data measured by a type K thermocouple to determine the time to prompt the solenoid valve. Results from the experimental work had indicate a temperature reduction of 10°C from 45°C to 35°C in a span of 3 minutes under controlled irradiance values. The cooled PV panel had an increase in terms of power output and efficiency by 0.2W and 7.37% respectively.
- 2 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 53572-53580
Open AccessFPGA-Driven Thermal Management System for Photovoltaic Modules
This study discusses the design of a photovoltaic (PV) panel thermal management system driven by Field-Programmable Gate Array (FPGA). The efficiency of PV panels is often linked to their surface temperature. Since the increase in temperature on the surface of PV panels can hinder their efficiency, an effective thermal management system is needed to curb this problem. Therefore, a real-time cooling system has been designed by using an Altera DE-2 115 FPGA board integrated with K-type thermocouples and a solenoid valve to help regulate surface temperature and optimize PV panel efficiency. This system uses rainwater as the coolant to reduce panel temperature. This flow is controlled by a solenoid valve where this valve will automatically open when panel surface temperature reaches to 45 °C and will close again when the surface temperature has cooled down to 35 °C. The opening and closing of this solenoid valve are controlled by signals prompted by the FPGA board. The FPGA uses temperature data measured by a type K thermocouple to determine the time to prompt the solenoid valve. Results from the experimental work had indicate a temperature reduction of 10°C from 45°C to 35°C in a span of 3 minutes under controlled irradiance values. The cooled PV panel had an increase in terms of power output and efficiency by 0.2W and 7.37% respectively.
- 5 July 2025
- Published by Elsevier in Optics Communications
- Vol. 591
Characterization of absorption responses in ITO-coated fibers for acetone gas sensing in the near-infrared region
- 5 July 2025
- Published by Elsevier in Optics Communications
- Vol. 591
Characterization of absorption responses in ITO-coated fibers for acetone gas sensing in the near-infrared region
- Open Access
- 1 April 2023
- Published by ASTES Journal in Advances in Science, Technology and Engineering Systems Journal
- Vol. 8 (2) , 123-129
Assessment of Scattered-Bend Loss in Polymer Optical Fiber (POF) Displacement Sensor
- 1 April 2023
- Published by ASTES Journal in Advances in Science, Technology and Engineering Systems Journal
- Vol. 8 (2) , 123-129
Open AccessAssessment of Scattered-Bend Loss in Polymer Optical Fiber (POF) Displacement Sensor