Xingge Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xingge Xu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Shawninder Chahal
Department of Food Science and Agricultural Chemistry, McGill University, 21111 Lakeshore Rd, Sainte-Anne-de-Bellevue, QC, H9X 3V9, Canada
4 shared publications - Amine Abdelkader Kamen
Department of Bioengineering McGill University Montreal Canada
2 shared publications - Jeongbin Shin
Department of Bioengineering McGill University Montreal Canada
2 shared publications - Daniel Rüdiger
Max Planck Institute for Dynamics of Complex Technical Systems, Magdeburg, Germany
1 shared publication Heather D. Durham
Department of Neurology and Neurosurgery McGill University Quebec Canada
1 shared publicationIrshad Ali
Department of Chemical Engineering Faculty of Mechanical, Chemical and Industrial Engineering, University of Engineering & Technology Peshawar Pakistan
1 shared publication
Latest Publications
- Open Access
- 23 October 2026
- Published by Elsevier in Biochemical Engineering Journal
- Vol. 238
In-situ Raman spectroscopy for real-time monitoring of cell density and metabolites during adenovirus production in HEK293 suspension culture
- 23 October 2026
- Published by Elsevier in Biochemical Engineering Journal
- Vol. 238
Open AccessIn-situ Raman spectroscopy for real-time monitoring of cell density and metabolites during adenovirus production in HEK293 suspension culture
- Open Access
- 30 September 2026
- Published by Wiley in Biotechnology and Bioengineering
Mechanistic Digital Model for Real‐Time Monitoring and Optimization of Adenovirus Production
Adenoviral vectors are a critical vaccine platform, with billions of vaccine doses administered during the COVID‐19 pandemic. In addition, they are promising therapeutics for cancer treatment. To advance their manufacturing, real‐time monitoring of adenovirus production is essential for process optimization, yield improvement, and product quality assurance. However, despite modern bioreactors being equipped with advanced sensors, comprehensive monitoring of viral production in real‐time remains limited. In this work, we investigated potential indicators of the cell density effect (CDE), which imposes a trade‐off between high cell density and specific productivity, thereby hindering process optimization. Glucose availability (expressed as glucose per cell) at time of infection was identified as the most effective proxy indicator. We developed an age‐structured mechanistic model linking measurable process variables, such as glucose and viable cell density to viral production while capturing the CDE. This framework enables the prediction of viral particle titers in both batch and fed‐batch operation modes, achieving an RMSE of 0.39 in log 10 IVP/mL for infectious viral particles and 0.20 in log 10 VP/mL for total viral particles, corresponding to approximately 2.6 and 2.0 times the measurement standard deviation of the respective assays. The proposed model and calibration method lay the foundation for a digital twin of adenovirus production, bridging real‐time sensing with model‐based simulation to support adaptive control and accelerate the transition toward Biopharma 4.0.
- 30 September 2026
- Published by Wiley in Biotechnology and Bioengineering
Open AccessMechanistic Digital Model for Real‐Time Monitoring and Optimization of Adenovirus Production
Adenoviral vectors are a critical vaccine platform, with billions of vaccine doses administered during the COVID‐19 pandemic. In addition, they are promising therapeutics for cancer treatment. To advance their manufacturing, real‐time monitoring of adenovirus production is essential for process optimization, yield improvement, and product quality assurance. However, despite modern bioreactors being equipped with advanced sensors, comprehensive monitoring of viral production in real‐time remains limited. In this work, we investigated potential indicators of the cell density effect (CDE), which imposes a trade‐off between high cell density and specific productivity, thereby hindering process optimization. Glucose availability (expressed as glucose per cell) at time of infection was identified as the most effective proxy indicator. We developed an age‐structured mechanistic model linking measurable process variables, such as glucose and viable cell density to viral production while capturing the CDE. This framework enables the prediction of viral particle titers in both batch and fed‐batch operation modes, achieving an RMSE of 0.39 in log 10 IVP/mL for infectious viral particles and 0.20 in log 10 VP/mL for total viral particles, corresponding to approximately 2.6 and 2.0 times the measurement standard deviation of the respective assays. The proposed model and calibration method lay the foundation for a digital twin of adenovirus production, bridging real‐time sensing with model‐based simulation to support adaptive control and accelerate the transition toward Biopharma 4.0.
- 2 June 2026
- Published by Taylor & Francis
- p. 91-101
PAT and Process Control
- 2 June 2026
- Published by Taylor & Francis
- p. 75-90
Application of Machine Learning in PAT
- 2 June 2026
- Published by Taylor & Francis
- p. 61-74
Essential Analytics Framework for PAT Data Analysis
- 2 June 2026
- Published by Taylor & Francis
- p. 102-111
PAT for Process Modelling
- Open Access
- 27 June 2025
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 113 (7)
Iridium‐Bismuth‐Oxide Coatings for Use in Neural Stimulating Electrodes: The Influence of Ir/Bi Ratio
Implantable neural prosthetics with stimulating electrodes are increasingly employed in medical practices to treat neural disabilities. The electrode material is expected to provide high charge storage and injection capacity (CSC/CIC) and low impedance for safe, efficient, and precise neural stimulation, while at the same time, being small. To improve the current state‐of‐the‐art neural‐electrode material, iridium oxide (IrOx), Ir m Bi 1‐m Ox coatings of various compositions ( m = 0, 0.2, 0.4, 0.6, 0.8, and 1.0) produced by thermal deposition were evaluated. The Ir 0.8 Bi 0.2 Ox yielded a CSC of 17.7 ± 1.1 mC/cm 2 , which is four‐fold higher than that of IrOx. At the same time, the impedance of Ir 0.8 Bi 0.2 Ox at 1 kHz was measured to be half of that of IrOx. The superior performance of Ir 0.8 Bi 0.2 Ox was explained by forming amorphous structures that facilitate the intercalation of H + and OH − ions into deeper oxide structures that contribute to faradaic charge storage. The Ir 0.8 Bi 0.2 Ox electrode also showed good stability and biocompatibility, which makes it potentially a good candidate for neural stimulating electrodes.
- 27 June 2025
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 113 (7)
Open AccessIridium‐Bismuth‐Oxide Coatings for Use in Neural Stimulating Electrodes: The Influence of Ir/Bi Ratio
Implantable neural prosthetics with stimulating electrodes are increasingly employed in medical practices to treat neural disabilities. The electrode material is expected to provide high charge storage and injection capacity (CSC/CIC) and low impedance for safe, efficient, and precise neural stimulation, while at the same time, being small. To improve the current state‐of‐the‐art neural‐electrode material, iridium oxide (IrOx), Ir m Bi 1‐m Ox coatings of various compositions ( m = 0, 0.2, 0.4, 0.6, 0.8, and 1.0) produced by thermal deposition were evaluated. The Ir 0.8 Bi 0.2 Ox yielded a CSC of 17.7 ± 1.1 mC/cm 2 , which is four‐fold higher than that of IrOx. At the same time, the impedance of Ir 0.8 Bi 0.2 Ox at 1 kHz was measured to be half of that of IrOx. The superior performance of Ir 0.8 Bi 0.2 Ox was explained by forming amorphous structures that facilitate the intercalation of H + and OH − ions into deeper oxide structures that contribute to faradaic charge storage. The Ir 0.8 Bi 0.2 Ox electrode also showed good stability and biocompatibility, which makes it potentially a good candidate for neural stimulating electrodes.