Shao-Hua Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shao-Hua Ma has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Rui-Jun Li
Hefei University of Technology
3 shared publications - Zhen-Ying Cheng
Hefei University of Technology
3 shared publications - Kai Jiang
School of Instrument Science and Opto-electronic Engineering, Hefei University of Technology, Hefei, China
1 shared publication - Li-Ying Liu
Hefei University of Technology, School of Instrument Science and Opto-electronics Engineering, Anhui, Hefei 230009, People’s Republic of China
1 shared publication - Meng-Ting Cheng
School of Instrument Science and Opto-electronic Engineering, Hefei University of Technology, Hefei, China
1 shared publication - Qiaosheng Pan
School of Instrument Science and Opto-electronic Engineering, Hefei University of Technology, Hefei, China
1 shared publication
Latest Publications
- 18 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
Development of a Low-stiffness and High-dynamic Micro–Nano Probe Utilizing the Eddy Current Damper
Micro–nano probes are crucial components of micro/nano coordinate measuring machines. Most probes rely on low-stiffness elastic mechanisms, resulting in prolonged settling times and large dynamic errors. A micro–nano probe with low stiffness and high dynamic performance based on an eddy current damper (ECD) was developed to address these issues. The probe’s dynamic performance optimization was achieved through comprehensive static and dynamic analyses. The design and optimization of the ECD were carried out through theoretical modeling and simulation analysis. Experimental results indicate that the stiffness of the optimized probe remains almost unchanged, with an average horizontal stiffness of 0.711 mN/μm and a vertical stiffness of 0.258 mN/μm. The settling time is reduced by approximately 90% to less than 1.0 s. The proposed probe, characterized by its low stiffness and high dynamic performance, meets the high-precision and high-efficiency measurement requirements for micro components.
- 18 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
Development of a Low-stiffness and High-dynamic Micro–Nano Probe Utilizing the Eddy Current Damper
Micro–nano probes are crucial components of micro/nano coordinate measuring machines. Most probes rely on low-stiffness elastic mechanisms, resulting in prolonged settling times and large dynamic errors. A micro–nano probe with low stiffness and high dynamic performance based on an eddy current damper (ECD) was developed to address these issues. The probe’s dynamic performance optimization was achieved through comprehensive static and dynamic analyses. The design and optimization of the ECD were carried out through theoretical modeling and simulation analysis. Experimental results indicate that the stiffness of the optimized probe remains almost unchanged, with an average horizontal stiffness of 0.711 mN/μm and a vertical stiffness of 0.258 mN/μm. The settling time is reduced by approximately 90% to less than 1.0 s. The proposed probe, characterized by its low stiffness and high dynamic performance, meets the high-precision and high-efficiency measurement requirements for micro components.
- 30 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (17) , 32870-32879
Modeling and Topology Optimization of the Thermal Stability in Laser 4-DOF Measurement Systems
A novel design method based on topology optimization is proposed and demonstrated to enhance thermal stability in laser four-degree-of-freedom (4-DOF) measurement systems against environmental temperature fluctuations. The overall thermal deformation of the measurement systems is calculated by finite element analysis. The thermal errors caused by thermal deformation of workpieces are analyzed and modeled. The workpieces of the 4-DOF measurement systems are designed using topology optimization, resulting in a 50% reduction in thermal deformation. Furthermore, the temperature field of the measurement system is optimized by incorporating thermal insulation materials, and stability experiments are performed on the system both before and after optimization. The stability of the laser beam is improved by 53.9%, 49.0%, 58.0%, and 52.5% in two angular and two straightness directions, respectively. Experimental results demonstrate that the proposed method effectively enhances the stability of the 4-DOF measurement systems and can be applied to improve the thermal stability of other precision instruments.
- 30 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (17) , 32870-32879
Modeling and Topology Optimization of the Thermal Stability in Laser 4-DOF Measurement Systems
A novel design method based on topology optimization is proposed and demonstrated to enhance thermal stability in laser four-degree-of-freedom (4-DOF) measurement systems against environmental temperature fluctuations. The overall thermal deformation of the measurement systems is calculated by finite element analysis. The thermal errors caused by thermal deformation of workpieces are analyzed and modeled. The workpieces of the 4-DOF measurement systems are designed using topology optimization, resulting in a 50% reduction in thermal deformation. Furthermore, the temperature field of the measurement system is optimized by incorporating thermal insulation materials, and stability experiments are performed on the system both before and after optimization. The stability of the laser beam is improved by 53.9%, 49.0%, 58.0%, and 52.5% in two angular and two straightness directions, respectively. Experimental results demonstrate that the proposed method effectively enhances the stability of the 4-DOF measurement systems and can be applied to improve the thermal stability of other precision instruments.
- 7 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
Multi-functional Laser Calibrator for Multi Parameters Measurement in Motion Axis Assembly
The assembly accuracy of motion axis of machine tool is determined by multi parameters, including geometric errors of linear guides and parallelism between multi axis, named error equalization effect. This article proposes a multi-functional laser calibrator, which is consisted of a novel five degree of freedom measurement (5-DOFM) system and a dual-axis precision level with a pentagonal prism. The geometric errors of linear guide (including straightness errors, pitch, yaw and roll angular errors) and parallelism between multi axis could be detected conveniently. Especially, the influence of the pentagonal prism on parallelism measurement was investigated and proved using reflection matrices. A series of validation experiments were conducted to demonstrate the effectiveness of laser calibrator. The experiments results reveal that designed laser calibrator can achieve measurement range of ± 150 um for straightness errors detection, and ± 200″ for angular errors detection. The measurement error of parallelism between multi guide rails can be controlled less than 1″ (5 um/m) according the analysis results of the pentagonal prism. The proposed instrument can provide numerical reference for the research of motion axis error equalization effect and the improvement of assembly accuracy.
- 7 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
Multi-functional Laser Calibrator for Multi Parameters Measurement in Motion Axis Assembly
The assembly accuracy of motion axis of machine tool is determined by multi parameters, including geometric errors of linear guides and parallelism between multi axis, named error equalization effect. This article proposes a multi-functional laser calibrator, which is consisted of a novel five degree of freedom measurement (5-DOFM) system and a dual-axis precision level with a pentagonal prism. The geometric errors of linear guide (including straightness errors, pitch, yaw and roll angular errors) and parallelism between multi axis could be detected conveniently. Especially, the influence of the pentagonal prism on parallelism measurement was investigated and proved using reflection matrices. A series of validation experiments were conducted to demonstrate the effectiveness of laser calibrator. The experiments results reveal that designed laser calibrator can achieve measurement range of ± 150 um for straightness errors detection, and ± 200″ for angular errors detection. The measurement error of parallelism between multi guide rails can be controlled less than 1″ (5 um/m) according the analysis results of the pentagonal prism. The proposed instrument can provide numerical reference for the research of motion axis error equalization effect and the improvement of assembly accuracy.