WPWeerawat Pornroongruengchok

Weerawat Pornroongruengchok

*This is an algorithmically generated author record based on publicly available information.

Weerawat Pornroongruengchok has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design and Geant4 simulation of an energy degrader system for PIXE and PIGE at the TINT cyclotron facility

    by Ekkachai Kongmon, Sarinrat Wonglee, Weerawat Pornroongruengchok, Phalakorn Khwansungnoen, Khwanjira Tangpong, Akkapob Ngamlamiad, Kitisak Komnoi, Thanabodee Sookchuay, Adundet Khurasi, Wutthichok Sangwang, et al.

  • Open Access

    Microwave-Assisted Biosynthesis of Silver Nanoparticles Using Chlorella sp. for Antibacterial and Cytotoxicity Effects of Breast Cancer Cell Line

    by Piyapan Manklinniam, Weerawat Pornroongruengchok, Saranya Phunpruch, Adisorn Phaepilin, Grissana Pook-In, Atchariya Yosboonruang, Sarinrat Wonglee, Piyanud Thongjerm, Worakrit Worananthakij

    Microwave-assisted biosynthesis using marine Chlorella sp. extracts provides a green and efficient route for the production of silver nanoparticles (AgNPs). Compared with the conventional method (24 h), microwave-assisted synthesis reduces the reaction time to less than 7 min while producing smaller and more uniformly distributed nanoparticles. AgNPs were synthesized using extracts obtained with different solvents and directly compared with those produced via the conventional method to substantiate the efficiency of the microwave-assisted approach. UV–visible spectroscopy confirmed rapid nanoparticle formation, exhibiting surface plasmon resonance peaks in the range of 405 to 427 nm. TEM analysis revealed predominantly spherical AgNPs with particle sizes of approximately 10 to 20 nm. The XRD and FTIR analyses confirmed their crystalline structure and stabilization by algal-derived functional groups. The biological activities of the AgNPs were dependent on the extraction solvent. AgNPs synthesized using hexane extracts exhibited pronounced antibacterial activity, achieving minimum inhibitory concentrations as low as 0.31 µg/mL. In addition, the AgNP induced concentration-dependent cytotoxic effects in human breast cancer cell lines. IC50 values, determined via dose–response analysis, ranged from 0.18 to 0.67 μg/mL in MDA-MB-231 cells and 1.70 to 8.42 μg/mL in MCF-7 cells. These results indicate a potent cytotoxic profile, with MDA-MB-231 cells exhibiting significantly higher sensitivity to the microwave-assisted formulations. Collectively, these findings highlight microwave-assisted algal-mediated biosynthesis as a sustainable and effective platform for generating bioactive AgNPs with promising antibacterial and anticancer potential.


  • Open Access

    GEANT4 Simulation of Proton Beam Properties from a Cyclotron Accelerator at King Chulalongkorn Memorial Hospital

    by Piyanud Thongjerm, Ekkachai Kongmon, Khwanjira Tangpong, Phalakorn Khwansungnoen, Sarinrat Wonglee, Weerawat Pornroongruengchok, Nantanat Chailanggar

    The main objective of proton beam therapy is to precisely irradiate diseased tissue while minimizing damage to healthy cells. For effective treatment, the linear energy transfer (LET) is a key parameter in ensuring the destruction of diseased cells, and both the dose and LET are typically represented as functions of depth. The distribution of dose and LET in the target depends on the beam properties, including beam energy, energy spread, beam size, and beam emittance. The aim of this work is to present the method used to characterize the proton beam properties obtained from the machine employed in the simulation and to determine the dose and dose-averaged LET (LETd) values, including their peak positions in depth. These results are used to predict the dose and LETd at different depth positions under experimental conditions. We utilized GEANT4, a Monte Carlo (MC) simulation-based software, to examine the integral depth-dose position and the peak position of the LETd. The proton source was obtained from a cyclotron accelerator, specifically the Varian ProBeam Compact spot scanning system at King Chulalongkorn Memorial Hospital in Bangkok, Thailand. The system provides proton energies ranging from 70 MeV to 220 MeV. In this study, four proton energies—70 MeV, 100 MeV, 150 MeV, and 220 MeV—were chosen to characterize the beam properties. The 80%–20% distal fall-off obtained from the simulation was used to determine the energy spread for each selected energy by matching the depth-dose peak with the measurement data. The optimal energy spreads were found to be 1.5%, 1.25%, 1%, and 0.5% for proton energies of 70 MeV, 100 MeV, 150 MeV, and 220 MeV, respectively. These energy spreads ensure that the difference in the depth-dose profile is below 1% when comparing the simulated and measured depth-dose profiles. Furthermore, the peak LETd was found to be approximately 1 mm away from the R80 position, a depth that corresponds to 80% of maximum dose, for each energy. This information can be used to guide the desired LETd position by utilizing the R80 depth position.