Michael Wagner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael Wagner has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Uwe Hampel
Helmholtz-Zentrum Dresden - Rossendorf, Institute of Fluid Dynamics, Bautzner Landstraße 400, 01328 Dresden, Germany
3 shared publications - André Bieberle
Helmholtz-Zentrum Dresden-Rossendorf , Bautzner Landstraße 400
2 shared publications - Suzanne Eisenhofer
Chair of Imaging Techniques in Energy and Process, Technische Universität Dresden 1 , Dresden
2 shared publications A. Bieberle
Helmholtz—Zentrum Dresden-Rossendorf 2 , Bautzner Landstrasse 400, 01328 Dresden
1 shared publication- Guruprasad Rao
Institute of Applied Computer Sciences, Lodz University of Technology, 90-924 Lodz, Poland
1 shared publication - Johann Wolf1 shared publication
Latest Publications
- Open Access
- 18 September 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (11)
Design studies on large muon trigger detectors using silicon photomultiplier devices
This work presents the design and experimental evaluation of muon trigger detectors tailored for industrial-scale applications. Studies were conducted using an organic scintillator plate measuring 250×250×10mm3, configured with varying numbers of silicon photomultiplier (SiPM) devices, each with a detection area of 4×4mm2. Various reflective materials, such as reflective paint, aluminum foil, and high-gloss paper, were applied to enhance the detected scintillation photon yield. Particular attention was given to optimize dark count suppression and muon event discrimination. Four detector configurations were designed, optimized, and evaluated individually. Spatially resolved muon detection efficiency was assessed using a muon coincidence detector with an active area of 50×50mm2. The assembly procedures for the different detector configurations are also discussed. Finally, a trigger detector configuration incorporating a single SiPM device coupled with a wavelength-shifting fiber clamp was identified as providing the most efficient collection for scintillation photon yield. This configuration is cost-effective, modular, and easy to mass-produce, making it well-suited for the developing of large-scale muon trigger detectors for industrial applications.
- 18 September 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (11)
Open AccessDesign studies on large muon trigger detectors using silicon photomultiplier devices
This work presents the design and experimental evaluation of muon trigger detectors tailored for industrial-scale applications. Studies were conducted using an organic scintillator plate measuring 250×250×10mm3, configured with varying numbers of silicon photomultiplier (SiPM) devices, each with a detection area of 4×4mm2. Various reflective materials, such as reflective paint, aluminum foil, and high-gloss paper, were applied to enhance the detected scintillation photon yield. Particular attention was given to optimize dark count suppression and muon event discrimination. Four detector configurations were designed, optimized, and evaluated individually. Spatially resolved muon detection efficiency was assessed using a muon coincidence detector with an active area of 50×50mm2. The assembly procedures for the different detector configurations are also discussed. Finally, a trigger detector configuration incorporating a single SiPM device coupled with a wavelength-shifting fiber clamp was identified as providing the most efficient collection for scintillation photon yield. This configuration is cost-effective, modular, and easy to mass-produce, making it well-suited for the developing of large-scale muon trigger detectors for industrial applications.
- Open Access
- 2 July 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (1)
Algebraic image reconstruction for muon scattering computed tomography without tracing
We have developed a new algebraic image reconstruction algorithm for muon scattering computed tomography. In this method, the track of a muon is recorded by suitable detectors before and after passing an object of interest, and the total scattering of the muon in the object is determined by comparing the incoming and outgoing tracks. From a certain minimum number of muons, the scattering density distribution of the object can be reconstructed from the measurement data. In contrast to other reconstruction algorithms, our approach does not estimate the unknown muon track in the object, which minimizes systematic errors for objects with complex geometries. In this paper, the new algorithm is derived, analyzed with respect to freely selectable parameters, and tested on simulation data for a virtual phantom. The results are compared with an existing algebraic reconstruction algorithm.
- 2 July 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (1)
Open AccessAlgebraic image reconstruction for muon scattering computed tomography without tracing
We have developed a new algebraic image reconstruction algorithm for muon scattering computed tomography. In this method, the track of a muon is recorded by suitable detectors before and after passing an object of interest, and the total scattering of the muon in the object is determined by comparing the incoming and outgoing tracks. From a certain minimum number of muons, the scattering density distribution of the object can be reconstructed from the measurement data. In contrast to other reconstruction algorithms, our approach does not estimate the unknown muon track in the object, which minimizes systematic errors for objects with complex geometries. In this paper, the new algorithm is derived, analyzed with respect to freely selectable parameters, and tested on simulation data for a virtual phantom. The results are compared with an existing algebraic reconstruction algorithm.