Dulce Natalia Castillo-López
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Dulce Natalia Castillo-López has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Arnulfo Luis-Ramos
Facultad de Ciencias de la Electrónica, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico
1 shared publication - Celia Lizeth Gomez
Instituto de Ciencias, Benemérita Universidad Autónoma de Puebla, 72570, Puebla, México
1 shared publication David Saúl Villegas-Cantoran
Grupo de Sistemas Fotónicos y Nanoóptica, Facultad de Ciencias de la Electrónica, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico
1 shared publication- Luz del Carmen Gómez Pavón
Benemerita Universidad Autónoma de Puebla (BUAP)
1 shared publication - Orlando Zaca-Moran
Centro de Investigación en Biotecnología Aplicada, Instituto Politécnico Nacional
1 shared publication - Placido Zaca Moran
Instituto de Ciencias, Benemérita Universidad Autónoma de Puebla, 72960, Puebla City, Mexico.
1 shared publication
Latest Publications
- Open Access
- 10 July 2025
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 7 (3) , 035021
Biosensor for human chorionic gonadotropin detection using gold nanoparticles-decorated tapered optical fiber
This work presents a biosensor based on a tapered optical fiber decorated with gold nanoparticles for the detection of human chorionic gonadotropin hormone in water and urine. The tapered optical fiber, fabricated by the flame-brushing technique, has a waist diameter of approximately 3.5 µm, where gold nanoparticles with a size of 100 nm were deposited through photodeposition using a continuous-wave 1535 nm laser. Detection was performed for hCG hormone solutions prepared in tri-distilled water and human urine, covering a concentration range from 1 mIU ml−1 to 180 mIU ml−1, which is clinically relevant for cancer detection. The biosensor showed a spectral shift in output wavelength and a variation in output optical power as a function of hCG hormone concentration, enabling a quantifiable, reproducible, and specific detection. The limits of detection were 0.04 mIU ml−1 for the solution in tri-distilled water and 0.03 mIU ml−1 for the solution in urine, with sensitivity of 0.012 nm (mIU ml−1)−1 and 0.021 nm (mIU ml−1)−1, respectively. The proposed biosensor is capable of specifically detecting the hCG hormone at different levels of concentration without the use of antigens as bioreceptors. These results demonstrate the potential of optical fiber non functionalized biosensors decorated with metallic nanoparticles for developing highly sensitive biosensors with biomedical applications, opening new possibilities for the early diagnosis of diseases associated with abnormal expression of the hCG hormone.
- 10 July 2025
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 7 (3) , 035021
Open AccessBiosensor for human chorionic gonadotropin detection using gold nanoparticles-decorated tapered optical fiber
This work presents a biosensor based on a tapered optical fiber decorated with gold nanoparticles for the detection of human chorionic gonadotropin hormone in water and urine. The tapered optical fiber, fabricated by the flame-brushing technique, has a waist diameter of approximately 3.5 µm, where gold nanoparticles with a size of 100 nm were deposited through photodeposition using a continuous-wave 1535 nm laser. Detection was performed for hCG hormone solutions prepared in tri-distilled water and human urine, covering a concentration range from 1 mIU ml−1 to 180 mIU ml−1, which is clinically relevant for cancer detection. The biosensor showed a spectral shift in output wavelength and a variation in output optical power as a function of hCG hormone concentration, enabling a quantifiable, reproducible, and specific detection. The limits of detection were 0.04 mIU ml−1 for the solution in tri-distilled water and 0.03 mIU ml−1 for the solution in urine, with sensitivity of 0.012 nm (mIU ml−1)−1 and 0.021 nm (mIU ml−1)−1, respectively. The proposed biosensor is capable of specifically detecting the hCG hormone at different levels of concentration without the use of antigens as bioreceptors. These results demonstrate the potential of optical fiber non functionalized biosensors decorated with metallic nanoparticles for developing highly sensitive biosensors with biomedical applications, opening new possibilities for the early diagnosis of diseases associated with abnormal expression of the hCG hormone.