Shreya Ravi has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A case report on the integration of the Monitored Augmented Rehabilitation System in a multidisciplinary rehabilitation program for a pediatric patient with a ruptured arteriovenous malformation

    by Samuel T. Lauman, Shreya Ravi, Kara Chaplin, Megan Roberts, Deanna Lusty, Diana Early, Stephen Kimatian, Sarah Rebstock

    Cerebral arteriovenous malformations (AVMs) are congenital vascular abnormalities that can lead to neurological impairments following rupture. This proof-of-concept case report examines the integration of the Monitored Augmented Rehabilitation System (MARS), an immersive virtual gaming platform, into a multidisciplinary rehabilitation program for a 12-year-old female recovering from a ruptured AVM. MARS was used as an adjunct modality alongside conventional interventions over a 4-week period to target functional outcomes as assessed by the Neurocom Balance Manager ® . Quantitative results demonstrated targeted functional gains: Directional Control during the Limits of Stability test increased from 66% to 73%, toes-up Adaptation Test scores improved from 104.2 to 116.2, and toes-down scores from 115.6 to 119.0. Clinically observed increases in engagement, motivation, and adherence were noted during therapy sessions. This report underscores the feasibility and clinical potential of MARS as a complementary tool for enhancing motor learning and functional outcomes in pediatric neurorehabilitation. Future research should focus on larger sample sizes and extended intervention periods to validate the efficacy of MARS in improving long-term recovery outcomes.

  • Open Access

    Assessing the Accuracy and Reliability of the Monitored Augmented Rehabilitation System for Measuring Shoulder and Elbow Range of Motion

    by Samuel T. Lauman, Lindsey J. Patton, Pauline Chen, Shreya Ravi, Stephen J. Kimatian, Sarah E. Rebstock

    Accurate range of motion (ROM) assessment is essential for evaluating musculoskeletal function and guiding rehabilitation, particularly in pediatric populations. Traditional methods, such as optical motion capture and handheld goniometry, are often limited by cost, accessibility, and inter-rater variability. This study evaluated the feasibility and accuracy of the Microsoft Azure Kinect-powered Monitored Augmented Rehabilitation System (MARS) compared to Kinovea. Sixty-five pediatric participants (ages 5–18) performed standardized shoulder and elbow movements in the frontal and sagittal planes. ROM data were recorded using MARS and compared to Kinovea. Measurement reliability was evaluated using intraclass correlation coefficients (ICC3k), and accuracy was evaluated using root mean squared error (RMSE) analysis. MARS demonstrated excellent reliability with an average ICC3k of 0.993 and met the predefined accuracy threshold (RMSE ≤ 8°) for most movements, with the exception of sagittal elbow flexion. These findings suggest that MARS is a reliable, accurate, and cost-effective alternative for clinical ROM assessment, offering a markerless solution that enhances measurement precision and accessibility in pediatric rehabilitation. Future studies should enhance accuracy in sagittal plane movements and further validate MARS against gold-standard systems.