Jungwoo Kim
Jungwoo Kim has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Kwon-Yeong Lee
Department of Mechanical and Control Engineering, Handong Global University, Pohang 37554, Republic of Korea
2 shared publications - Dong Kyou Park
Department of Electromechanical Convergence Engineering, Korea University of Technology and Education, Cheonan 31253, Republic of Korea
1 shared publication Hyunjun Sun
1 shared publication- Hyunjun Sun1 shared publication
Hyunsu Kang
1 shared publicationJaedal Lee
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by Wiley in International Journal of Energy Research
- Vol. 2025 (1)
Experimental Study on the Heat Transfer Performance of Dielectric Fluids in a Two‐Phase Closed Thermosyphon
This study experimentally evaluated the thermal performance of two‐phase closed thermosyphons (TPCTs) using dielectric fluids. Experimental results showed that HFE‐7100 and HFE‐7200 exhibit maximum allowable powers that are up to 78.2% and 80% lower than that of DI water. These results were obtained under the condition of FR of 0.25. At this condition, the confinement numbers for DI water, HFE‐7100, and HFE‐7200 were 0.247, 0.087, and 0.090. However, dielectric fluids demonstrated more stable operation by preventing the geyser boiling phenomenon. Particularly, HFE‐7100 exhibited the lowest thermal resistance below 130 W heat inputs. These findings are expected to provide a valuable foundation for developing high‐efficiency cooling technologies for high‐power electronics and energy systems.
- 1 January 2025
- Published by Wiley in International Journal of Energy Research
- Vol. 2025 (1)
Open AccessExperimental Study on the Heat Transfer Performance of Dielectric Fluids in a Two‐Phase Closed Thermosyphon
This study experimentally evaluated the thermal performance of two‐phase closed thermosyphons (TPCTs) using dielectric fluids. Experimental results showed that HFE‐7100 and HFE‐7200 exhibit maximum allowable powers that are up to 78.2% and 80% lower than that of DI water. These results were obtained under the condition of FR of 0.25. At this condition, the confinement numbers for DI water, HFE‐7100, and HFE‐7200 were 0.247, 0.087, and 0.090. However, dielectric fluids demonstrated more stable operation by preventing the geyser boiling phenomenon. Particularly, HFE‐7100 exhibited the lowest thermal resistance below 130 W heat inputs. These findings are expected to provide a valuable foundation for developing high‐efficiency cooling technologies for high‐power electronics and energy systems.