James H. Briggs
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
James H. Briggs has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- George William John Harston
Acute Stroke Service, Oxford University Hospitals National Health Service Foundation Trust, United Kingdom (G.W.J.H.).
3 shared publications Abdulrahman Al Halak
From the Rockefeller Neuroscience Institute (A.T.R., A.A.H., D.L.), West Virginia University, Morgantown, West Virginia
1 shared publicationAliki Sifostratoudaki
Brainomix, Oxford, UK
1 shared publicationAlistair Perry
Brainomix Limited (A.P., O.J., P.B., J.H.B., Z.V.J.W., G.H., D.C.), Oxford, United Kingdom
1 shared publicationAnand Devaraj
Interstitial Lung Disease Unit, Royal Brompton Hospital, London, UK
1 shared publication- Anna Podlasek
Image Guided Therapy Research Facility, University of Dundee, Dundee DD1 4HN, UK
1 shared publication
Latest Publications
- Open Access
- 18 December 2025
- Published by European Respiratory Society (ERS) in ERJ Open Research
- Vol. 12 (3)
e-Lung computed tomography biomarkers are associated with outcomes in fibrotic interstitial lung diseases
Background: The e-Lung weighted reticulovascular score (WRVS) is an automated computed tomography biomarker that quantifies interstitial lung disease (ILD) severity and is associated with prognosis in patients with idiopathic pulmonary fibrosis (IPF). The aims of the present study were to evaluate WRVS as a prognostic factor in patients with non-IPF ILD. Methods: The test cohort comprised patients from the Open Source Imaging Consortium and the validation cohort, patients recruited to the prospective German CoWorker ILD registry. Associations between baseline and serial WRVS with future forced vital capacity (FVC) decline and survival were tested. Results: Median survival was 7.1 and 6.1 years in the test (n=302) and validation (n=378) cohorts, respectively. Baseline WRVS was associated with mortality in test (hazard ratio (HR) 1.11, 95% CI 1.08–1.14; p<0.001, C-index 0.75) and validation (HR 1.12, 95% CI 1.09–1.15; p<0.001, C-index 0.72) cohorts. A threshold WRVS of ≥15% was associated with mortality in both cohorts (HR 4.77, 95% CI 3.11–7.31; p<0.001, C-index 0.71, and HR 3.49, 95% CI 2.48–4.91; p<0.001, C-index 0.63 for test and validation cohorts, respectively). After adjustment for FVC, age and sex, baseline WRVS was associated with future FVC decline or death in test (OR 1.13, 95% CI 1.06–1.21; p<0.001, C-index 0.72) and validation (OR 1.18, 95% CI 1.11–1.25; p<0.001, C-index 0.72) cohorts. A rise in WRVS of 3% on serial computed tomography was associated with mortality in both test (HR 5.69, 95% CI 2.77–11.70; p<0.001, C-index 0.75) and validation cohorts (HR 1.99, 95% CI 1.09–3.65; p=0.026, C-index 0.57). Conclusion: In patients with non-IPF ILD, the e-Lung WRVS biomarker is associated with mortality and FVC decline when applied to baseline high-resolution computed tomography scans replicating previous studies in IPF. Patients with an increase in WRVS of 3% on serial computed tomography scans have significantly increased risk of mortality.
- 18 December 2025
- Published by European Respiratory Society (ERS) in ERJ Open Research
- Vol. 12 (3)
Open Accesse-Lung computed tomography biomarkers are associated with outcomes in fibrotic interstitial lung diseases
Background: The e-Lung weighted reticulovascular score (WRVS) is an automated computed tomography biomarker that quantifies interstitial lung disease (ILD) severity and is associated with prognosis in patients with idiopathic pulmonary fibrosis (IPF). The aims of the present study were to evaluate WRVS as a prognostic factor in patients with non-IPF ILD. Methods: The test cohort comprised patients from the Open Source Imaging Consortium and the validation cohort, patients recruited to the prospective German CoWorker ILD registry. Associations between baseline and serial WRVS with future forced vital capacity (FVC) decline and survival were tested. Results: Median survival was 7.1 and 6.1 years in the test (n=302) and validation (n=378) cohorts, respectively. Baseline WRVS was associated with mortality in test (hazard ratio (HR) 1.11, 95% CI 1.08–1.14; p<0.001, C-index 0.75) and validation (HR 1.12, 95% CI 1.09–1.15; p<0.001, C-index 0.72) cohorts. A threshold WRVS of ≥15% was associated with mortality in both cohorts (HR 4.77, 95% CI 3.11–7.31; p<0.001, C-index 0.71, and HR 3.49, 95% CI 2.48–4.91; p<0.001, C-index 0.63 for test and validation cohorts, respectively). After adjustment for FVC, age and sex, baseline WRVS was associated with future FVC decline or death in test (OR 1.13, 95% CI 1.06–1.21; p<0.001, C-index 0.72) and validation (OR 1.18, 95% CI 1.11–1.25; p<0.001, C-index 0.72) cohorts. A rise in WRVS of 3% on serial computed tomography was associated with mortality in both test (HR 5.69, 95% CI 2.77–11.70; p<0.001, C-index 0.75) and validation cohorts (HR 1.99, 95% CI 1.09–3.65; p=0.026, C-index 0.57). Conclusion: In patients with non-IPF ILD, the e-Lung WRVS biomarker is associated with mortality and FVC decline when applied to baseline high-resolution computed tomography scans replicating previous studies in IPF. Patients with an increase in WRVS of 3% on serial computed tomography scans have significantly increased risk of mortality.
- 9 October 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (12) , 2528-2534
Artificial Intelligence–Driven Detection of Large Vessel Occlusions on NCCT: A Multi-Institutional Study
BACKGROUND AND PURPOSE: Imaging triage of stroke patients is primarily based on perfusion imaging. Simplified triage based on non-contrast CT are limited (NCCT). To evaluate the predictive capability of a deep learning algorithm, “Triage Stroke” (Brainomix 360) in identifying anterior circulation large vessel occlusions (LVO) on NCCT in patients with suspected acute ischemic stroke (AIS). MATERIALS AND METHODS: This multi-institutional study analyzed 612 patients with suspected AIS at 3 US comprehensive stroke centers. A balanced cohort of consecutive patients with and without anterior circulation LVO was analyzed. Ground truth was based on concurrent CTA evaluated by site neuroradiologists. The primary outcome was predictive performance for LVO detection. The secondary outcomes were 1) prospective comparison of NCCT LVO detection against general radiologists and subspecialty neuroradiologists, and 2) the influence of NIHSS on the model. RESULTS: Triage Stroke software detected an LVO on NCCT with a 67% sensitivity and 93% specificity. The positive and negative predictive values were 59% and 95%, respectively, with an area under the curve (AUC) of 0.8. The software’s sensitivity for LVO detection was significantly higher than the group average of all radiologists (difference = 20.5%; CI, 8.26–32.78; P = .001) and was also higher when separated into general and neuroradiology subgroups. The AUC for NCCT LVO was significantly higher than the group of all readers (difference = 11%; CI, 4%–17%; P < .001), and the nonexpert readers (difference = 13%, CI, 7%–20%; P < .001). The addition of NIHSS to the model yielded a high specificity (99%) and similar sensitivity (65%), resulting in the optimum positive predictive value of all models tested (91%). CONCLUSIONS: Triage Stroke software demonstrated strong predictive capabilities for NCCT detection of anterior circulation LVOs outperforming radiologists. Coupled with NIHSS it may simplify identification of endovascular candidates especially in resource-constrained environments worldwide. Graphical Abstract
- 9 October 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (12) , 2528-2534
Artificial Intelligence–Driven Detection of Large Vessel Occlusions on NCCT: A Multi-Institutional Study
BACKGROUND AND PURPOSE: Imaging triage of stroke patients is primarily based on perfusion imaging. Simplified triage based on non-contrast CT are limited (NCCT). To evaluate the predictive capability of a deep learning algorithm, “Triage Stroke” (Brainomix 360) in identifying anterior circulation large vessel occlusions (LVO) on NCCT in patients with suspected acute ischemic stroke (AIS). MATERIALS AND METHODS: This multi-institutional study analyzed 612 patients with suspected AIS at 3 US comprehensive stroke centers. A balanced cohort of consecutive patients with and without anterior circulation LVO was analyzed. Ground truth was based on concurrent CTA evaluated by site neuroradiologists. The primary outcome was predictive performance for LVO detection. The secondary outcomes were 1) prospective comparison of NCCT LVO detection against general radiologists and subspecialty neuroradiologists, and 2) the influence of NIHSS on the model. RESULTS: Triage Stroke software detected an LVO on NCCT with a 67% sensitivity and 93% specificity. The positive and negative predictive values were 59% and 95%, respectively, with an area under the curve (AUC) of 0.8. The software’s sensitivity for LVO detection was significantly higher than the group average of all radiologists (difference = 20.5%; CI, 8.26–32.78; P = .001) and was also higher when separated into general and neuroradiology subgroups. The AUC for NCCT LVO was significantly higher than the group of all readers (difference = 11%; CI, 4%–17%; P < .001), and the nonexpert readers (difference = 13%, CI, 7%–20%; P < .001). The addition of NIHSS to the model yielded a high specificity (99%) and similar sensitivity (65%), resulting in the optimum positive predictive value of all models tested (91%). CONCLUSIONS: Triage Stroke software demonstrated strong predictive capabilities for NCCT detection of anterior circulation LVOs outperforming radiologists. Coupled with NIHSS it may simplify identification of endovascular candidates especially in resource-constrained environments worldwide. Graphical Abstract
- Open Access
- 3 January 2025
- Published by Oxford University Press (OUP) in BJR|Artificial Intelligence
- Vol. 2 (1)
Artificial intelligence assisted detection of large vessel occlusion on CT angiography in acute stroke patients: a multi-reader multi-case study
Objectives: We assessed the impact of artificial intelligence (AI) software (e-CTA, Brainomix) on clinical decision-making in patients with suspected acute ischemic stroke. Methods: A retrospective, multi-reader-multi-case crossover design compared readers’ performance with vs without software support. Twenty cases were included, 10 with large vessel occlusion (LVO) and 10 without LVO. Twenty-one NHS clinicians, representing intended software users ranging in experience, conducted 2 sessions (washout period > 2 weeks). In session 1, software support was provided for 10 randomly selected cases. In session 2, support allocation was reversed. Outcome measures included LVO detection, collateral scoring, diagnosis, treatment decision, time taken and confidence. Results: Sensitivity, specificity, and accuracy of LVO detection improved with imaging software for LVO detection, with increased confidence and reduced time taken. There was no significant difference in collateral scoring or diagnoses. Conclusion: e-CTA can improve performance of NHS clinicians when interpreting acute stroke imaging. Advances in knowledge: This paper provides new evidence that AI decision support software has the capacity to improve the performance of representative users in the NHS when interpreting imaging to identify patients for acute stroke treatments.
- 3 January 2025
- Published by Oxford University Press (OUP) in BJR|Artificial Intelligence
- Vol. 2 (1)
Open AccessArtificial intelligence assisted detection of large vessel occlusion on CT angiography in acute stroke patients: a multi-reader multi-case study
Objectives: We assessed the impact of artificial intelligence (AI) software (e-CTA, Brainomix) on clinical decision-making in patients with suspected acute ischemic stroke. Methods: A retrospective, multi-reader-multi-case crossover design compared readers’ performance with vs without software support. Twenty cases were included, 10 with large vessel occlusion (LVO) and 10 without LVO. Twenty-one NHS clinicians, representing intended software users ranging in experience, conducted 2 sessions (washout period > 2 weeks). In session 1, software support was provided for 10 randomly selected cases. In session 2, support allocation was reversed. Outcome measures included LVO detection, collateral scoring, diagnosis, treatment decision, time taken and confidence. Results: Sensitivity, specificity, and accuracy of LVO detection improved with imaging software for LVO detection, with increased confidence and reduced time taken. There was no significant difference in collateral scoring or diagnoses. Conclusion: e-CTA can improve performance of NHS clinicians when interpreting acute stroke imaging. Advances in knowledge: This paper provides new evidence that AI decision support software has the capacity to improve the performance of representative users in the NHS when interpreting imaging to identify patients for acute stroke treatments.
- Open Access
- 1 January 2009
- Published by Springer Nature in Cases Journal
- Vol. 2 (1) , 6963
Amyloidosis presenting as bilateral transudative pleural effusions with normal cardiac investigations: a case report
A 66-year-old man with a diagnosis of monoclonal gammopathy of unknown significance was referred for investigation of bilateral transudative pleural effusions by the cardiology team. Echocardiography, myocardial perfusion scanning and left heart catheterisation were all normal or non diagnostic. Given significant occupational asbestos exposure in his twenties he underwent thoracoscopic pleural biopsy. This showed fibrous inflammation only. He subsequently developed proteinuria and peripheral oedema. Reanalysis of the pleural biopsy specimen for amyloidosis was positive. Pleural disease is an uncommon presentation of systemic amyloidosis. The aetiology of the pleural effusions is unclear and is not simply a consequence of cardiac or renal impairment.
- 1 January 2009
- Published by Springer Nature in Cases Journal
- Vol. 2 (1) , 6963
Open AccessAmyloidosis presenting as bilateral transudative pleural effusions with normal cardiac investigations: a case report
A 66-year-old man with a diagnosis of monoclonal gammopathy of unknown significance was referred for investigation of bilateral transudative pleural effusions by the cardiology team. Echocardiography, myocardial perfusion scanning and left heart catheterisation were all normal or non diagnostic. Given significant occupational asbestos exposure in his twenties he underwent thoracoscopic pleural biopsy. This showed fibrous inflammation only. He subsequently developed proteinuria and peripheral oedema. Reanalysis of the pleural biopsy specimen for amyloidosis was positive. Pleural disease is an uncommon presentation of systemic amyloidosis. The aetiology of the pleural effusions is unclear and is not simply a consequence of cardiac or renal impairment.
- 1 December 1990
- Published by Elsevier in American Journal of Infection Control
- Vol. 18 (6) , 383-385
Postdischarge, postoperative nosocomial infection surveillance using random sampling
- 1 December 1990
- Published by Elsevier in American Journal of Infection Control
- Vol. 18 (6) , 383-385
Postdischarge, postoperative nosocomial infection surveillance using random sampling