Oleh Velykohorskyi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Oleh Velykohorskyi has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Kostiantyn Brovko
V. N. Karazin Kharkiv National University
6 shared publications - Nataliia Vynokurova
Department of electrical engineering and electric power industry, V. N. Karazin Kharkiv National University, Kharkiv, Ukraine
4 shared publications - Pavlo Budanov
V. N. Karazin Kharkiv National University
3 shared publications - Pavlo Budanov
V.N. Karazin Kharkiv National University, Kharkiv, Ukraine
3 shared publications - Andrii Nosyk
National Technical University “Kharkiv Polytechnic Institute
2 shared publications - Ihor Kyrysov
V. N. Karazin Kharkiv National University
2 shared publications
Latest Publications
- Open Access
- 28 August 2026
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 4 (8 (142)) , 30-44
Improving a qualimetric method for assessing the operational quality of energy facilities by using digital twins
This study reports a qualimetric assessment of the performance quality of energy facilities based on the improved information-measurement systems using digital twins. The task addressed relates to the fact that the existing information-measurement system of a power unit at the power plant allows only for the operational control over the current state of the technological process but does not enable preventive assessment and forecasting of critical deviations in technological parameters. A method has been proposed in this work for the qualimetric assessment of energy facilities performance quality by using digital twins, which makes it possible to detect deterioration in the technical condition of energy equipment even before reaching critical parameter values. To implement the qualimetric method for assessing operational quality of an energy object, predictive algorithm stages have been proposed, which make it possible, based on a digital twin, to implement the transition from current reactive control to preventive management. A system of criteria and indicators of qualimetric assessment of operational quality of energy facilities has been compiled, which makes it possible to calculate the integrated predictive index. It has been shown that using a digital twin as part of the TP ACS, the pre-accident state of the turbine is predicted in 1 hour 53 minutes, and the emergency state in 3 hours 26 minutes. This makes it possible to make a timely preventive management decision and prevent the occurrence of an emergency. The results of validating the qualimetric method for assessing the operational quality of a power unit involving simulation models of digital twins under typical operating scenarios showed the correspondence of the quality of turbine operation for different modes of operation of the power unit
- 28 August 2026
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 4 (8 (142)) , 30-44
Open AccessImproving a qualimetric method for assessing the operational quality of energy facilities by using digital twins
This study reports a qualimetric assessment of the performance quality of energy facilities based on the improved information-measurement systems using digital twins. The task addressed relates to the fact that the existing information-measurement system of a power unit at the power plant allows only for the operational control over the current state of the technological process but does not enable preventive assessment and forecasting of critical deviations in technological parameters. A method has been proposed in this work for the qualimetric assessment of energy facilities performance quality by using digital twins, which makes it possible to detect deterioration in the technical condition of energy equipment even before reaching critical parameter values. To implement the qualimetric method for assessing operational quality of an energy object, predictive algorithm stages have been proposed, which make it possible, based on a digital twin, to implement the transition from current reactive control to preventive management. A system of criteria and indicators of qualimetric assessment of operational quality of energy facilities has been compiled, which makes it possible to calculate the integrated predictive index. It has been shown that using a digital twin as part of the TP ACS, the pre-accident state of the turbine is predicted in 1 hour 53 minutes, and the emergency state in 3 hours 26 minutes. This makes it possible to make a timely preventive management decision and prevent the occurrence of an emergency. The results of validating the qualimetric method for assessing the operational quality of a power unit involving simulation models of digital twins under typical operating scenarios showed the correspondence of the quality of turbine operation for different modes of operation of the power unit
- Open Access
- 29 June 2026
- Published by Igor Sikorsky Kyiv Polytechnic Institute in KPI Science News
- Vol. 143 (2)
SIMULATION MODEL OF A DIGITAL TWIN FOR AN NPP POWER UNIT TECHNOLOGICAL PROCESS
Background. Modern nuclear power plant (NPP) units are characterised by high structural complexity, multi-level hierarchical Information and Control (I&C) systems, and a vast number of interconnected technological parameters. Existing digital twin models primarily focus on individual physical processes – such as neutron kinetics, thermal hydraulics, or protection logic – often overlooking the comprehensive structure of control systems. The lack of a formalised approach for real-time assessment of subsystems’ hierarchical integrity limits the early detection of pre-accident states and proactive safety management. Objective. The paper aims to develop a simulation model of a digital twin for the NPP technological process based on a system-cluster approach. This method enables the assessment of the hierarchical, self-similar scaled structure of subsystems using fractal dimension as a quantitative metric. Methods. The study utilises a system-cluster approach, decomposing the power unit into functional sub-clusters: power control, protection system, coolant parameter regulation, and emergency shutdown. The mathematical framework integrates neutron kinetics equations, thermal-hydraulic relations, and logical-dynamic algorithms. To quantify structural complexity, the information space coverage method was employed to calculate fractal dimensions. The digital twin was implemented as a hardware-and-software complex integrated with the I&C, incorporating modules for data acquisition, structural identification, and predictive analytics. Results. Fractal dimension values were obtained for key subclusters of the power unit, reflecting their hierarchical complexity (notably, the maximum of 1.83 for the coolant control system and the minimum of 1.0 for the protection system). Normalised ranges of fractal dimension were determined as indicators of normal operation. Furthermore, a monitoring algorithm was developed to detect the loss of structural levels or subsystem degradation before functional failures manifest. Practical implementation demonstrated the feasibility of real-time structural diagnostics and adaptive response. Conclusions. The proposed fractal-cluster approach ensures comprehensive modelling of the NPP technological process by accounting for its hierarchical structure. Utilising fractal dimension as a structural diagnostic parameter expands the capabilities of traditional control methods and establishes the necessary framework for proactive safety management strategies based on digital twin technology.
- 29 June 2026
- Published by Igor Sikorsky Kyiv Polytechnic Institute in KPI Science News
- Vol. 143 (2)
Open AccessSIMULATION MODEL OF A DIGITAL TWIN FOR AN NPP POWER UNIT TECHNOLOGICAL PROCESS
Background. Modern nuclear power plant (NPP) units are characterised by high structural complexity, multi-level hierarchical Information and Control (I&C) systems, and a vast number of interconnected technological parameters. Existing digital twin models primarily focus on individual physical processes – such as neutron kinetics, thermal hydraulics, or protection logic – often overlooking the comprehensive structure of control systems. The lack of a formalised approach for real-time assessment of subsystems’ hierarchical integrity limits the early detection of pre-accident states and proactive safety management. Objective. The paper aims to develop a simulation model of a digital twin for the NPP technological process based on a system-cluster approach. This method enables the assessment of the hierarchical, self-similar scaled structure of subsystems using fractal dimension as a quantitative metric. Methods. The study utilises a system-cluster approach, decomposing the power unit into functional sub-clusters: power control, protection system, coolant parameter regulation, and emergency shutdown. The mathematical framework integrates neutron kinetics equations, thermal-hydraulic relations, and logical-dynamic algorithms. To quantify structural complexity, the information space coverage method was employed to calculate fractal dimensions. The digital twin was implemented as a hardware-and-software complex integrated with the I&C, incorporating modules for data acquisition, structural identification, and predictive analytics. Results. Fractal dimension values were obtained for key subclusters of the power unit, reflecting their hierarchical complexity (notably, the maximum of 1.83 for the coolant control system and the minimum of 1.0 for the protection system). Normalised ranges of fractal dimension were determined as indicators of normal operation. Furthermore, a monitoring algorithm was developed to detect the loss of structural levels or subsystem degradation before functional failures manifest. Practical implementation demonstrated the feasibility of real-time structural diagnostics and adaptive response. Conclusions. The proposed fractal-cluster approach ensures comprehensive modelling of the NPP technological process by accounting for its hierarchical structure. Utilising fractal dimension as a structural diagnostic parameter expands the capabilities of traditional control methods and establishes the necessary framework for proactive safety management strategies based on digital twin technology.
- 30 May 2026
- Published by V. N. Karazin Kharkiv National University in Engineering
- p. 32
FESTO LABORATORY EQUIPMENT AS A TOOL FOR EXPERIMENTAL MODELING OF ELECTRICAL SYSTEMS OF NPP POWER UNITS
The article explores the possibilities of using Festo laboratory equipment for experimental modeling and analysis of electrical systems of nuclear power plants with VVER-1000 reactors. The relevance of the work is due to the need to increase the reliability and stability of the operation of the power units' own needs systems, which ensure the continuous operation of automated electric drive systems of pumping equipment, heat removal systems, core cooling and safety systems. Power supply disruptions or deviations in electrical energy parameters can lead to a decrease in the efficiency of the functioning of technological equipment and create potential threats to the safe operation of the power unit. The paper proposes an experimental and analytical approach to the study of electromechanical processes in automated electric drive systems, taking into account dynamic characteristics, load nonlinearity and the influence of transient and emergency modes. A mathematical model of an asynchronous automated electric drive of a pumping unit has been developed, which is based on the equations of electromechanical equilibrium, the dependence of power consumption on the speed of rotation, as well as the analysis of active power in alternating current circuits. Particular attention is paid to taking into account the inertial properties of the mechanical system and the influence of changes in the supply voltage on the electromagnetic moment and the stability of the drive. Experimental studies were conducted on the Festo laboratory stand, which allowed to simulate normal, transient and emergency operating modes, in particular voltage sag, overload and loss of external power supply. During the experiment, the dependences between the supply voltage, the speed of rotation of the electric motor and the consumed power were obtained, which confirm the adequacy of the constructed theoretical models and their suitability for describing real processes in systems of own needs. An assessment of measurement errors was performed, which allowed to establish their permissible level and confirm the reliability of the results obtained. It is shown that the use of Festo laboratory complexes allows to effectively reproduce critical operating modes of electrical systems typical of VVER-1000 type power units, including power failure scenarios and dynamic transient processes. This is important for increasing the level of safety, reliability and efficiency of operation of nuclear power plants. The results obtained can be used in the educational process of training engineering personnel, in conducting scientific research, as well as for simulation modeling of emergency situations in energy systems.
- 30 May 2026
- Published by V. N. Karazin Kharkiv National University in Engineering
- p. 32
FESTO LABORATORY EQUIPMENT AS A TOOL FOR EXPERIMENTAL MODELING OF ELECTRICAL SYSTEMS OF NPP POWER UNITS
The article explores the possibilities of using Festo laboratory equipment for experimental modeling and analysis of electrical systems of nuclear power plants with VVER-1000 reactors. The relevance of the work is due to the need to increase the reliability and stability of the operation of the power units' own needs systems, which ensure the continuous operation of automated electric drive systems of pumping equipment, heat removal systems, core cooling and safety systems. Power supply disruptions or deviations in electrical energy parameters can lead to a decrease in the efficiency of the functioning of technological equipment and create potential threats to the safe operation of the power unit. The paper proposes an experimental and analytical approach to the study of electromechanical processes in automated electric drive systems, taking into account dynamic characteristics, load nonlinearity and the influence of transient and emergency modes. A mathematical model of an asynchronous automated electric drive of a pumping unit has been developed, which is based on the equations of electromechanical equilibrium, the dependence of power consumption on the speed of rotation, as well as the analysis of active power in alternating current circuits. Particular attention is paid to taking into account the inertial properties of the mechanical system and the influence of changes in the supply voltage on the electromagnetic moment and the stability of the drive. Experimental studies were conducted on the Festo laboratory stand, which allowed to simulate normal, transient and emergency operating modes, in particular voltage sag, overload and loss of external power supply. During the experiment, the dependences between the supply voltage, the speed of rotation of the electric motor and the consumed power were obtained, which confirm the adequacy of the constructed theoretical models and their suitability for describing real processes in systems of own needs. An assessment of measurement errors was performed, which allowed to establish their permissible level and confirm the reliability of the results obtained. It is shown that the use of Festo laboratory complexes allows to effectively reproduce critical operating modes of electrical systems typical of VVER-1000 type power units, including power failure scenarios and dynamic transient processes. This is important for increasing the level of safety, reliability and efficiency of operation of nuclear power plants. The results obtained can be used in the educational process of training engineering personnel, in conducting scientific research, as well as for simulation modeling of emergency situations in energy systems.
- Open Access
- 30 April 2026
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 2 (9 (140)) , 64-71
Construction of a digital twin model for a system that monitors the technical condition of a nuclear power plant power unit
This study investigates the process of continuous monitoring and control of the technological process parameters at a nuclear power plant power unit using a digital twin model implemented on the basis of a system-cluster approach. The task addressed relates to the lack of a comprehensive, integrated system for continuous monitoring of the technical condition of the power unit, capable of collecting, processing, and analyzing information from sensors and diagnostic subsystems in real time. It is proposed to model the state of the technological equipment at a power unit using a digital twin and a system-cluster approach. Within the framework of the study, a system-cluster architecture of a digital twin was designed, which reflects the interaction among the physical, analytical, and control levels of the power unit at a nuclear power plant. The work involved processing the technological process parameters coming from a sensor network with a frequency of 1–2 Hz, with a processing delay of no more than 1–3 s. The proposed information-fractal criterion provided an increase in the sensitivity of pre-accident detection by 15–25% compared to conventional methods, as well as made it possible to identify complex operating modes in the range of . The results have made it possible to solve the set tasks by integrating multi-scale fractal analysis, cluster organization of technical systems, and self-similarity modeling. The practical implementation of the digital twin has proven its capability to detect changes in the structure of the technological process with diagnostic accuracy at the level of 85–92%. The implementation of the digital twin model in the information-control systems of the power unit makes it possible to increase the reliability, safety, and efficiency of control.
- 30 April 2026
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 2 (9 (140)) , 64-71
Open AccessConstruction of a digital twin model for a system that monitors the technical condition of a nuclear power plant power unit
This study investigates the process of continuous monitoring and control of the technological process parameters at a nuclear power plant power unit using a digital twin model implemented on the basis of a system-cluster approach. The task addressed relates to the lack of a comprehensive, integrated system for continuous monitoring of the technical condition of the power unit, capable of collecting, processing, and analyzing information from sensors and diagnostic subsystems in real time. It is proposed to model the state of the technological equipment at a power unit using a digital twin and a system-cluster approach. Within the framework of the study, a system-cluster architecture of a digital twin was designed, which reflects the interaction among the physical, analytical, and control levels of the power unit at a nuclear power plant. The work involved processing the technological process parameters coming from a sensor network with a frequency of 1–2 Hz, with a processing delay of no more than 1–3 s. The proposed information-fractal criterion provided an increase in the sensitivity of pre-accident detection by 15–25% compared to conventional methods, as well as made it possible to identify complex operating modes in the range of . The results have made it possible to solve the set tasks by integrating multi-scale fractal analysis, cluster organization of technical systems, and self-similarity modeling. The practical implementation of the digital twin has proven its capability to detect changes in the structure of the technological process with diagnostic accuracy at the level of 85–92%. The implementation of the digital twin model in the information-control systems of the power unit makes it possible to increase the reliability, safety, and efficiency of control.
- Open Access
- 16 December 2025
- Published by Zhytomyr Polytechnic State University in Технічна інженерія
- No. 2(96),p. 58-67
Розробка інтегрованої моделі цифрового двійника для ефективної експлуатації енергоблоків АЕС
У статті представлено результати дослідження з розробки та впровадження інтегрованої моделі цифрового двійника енергоблоку атомної електростанції. Актуальність дослідження обумовлена потребою підвищення ефективності, безпеки та надійності експлуатації ядерних енергетичних установок в умовах цифровізації енергетики. Запропонована модель реалізує комплексне моделювання взаємопов’язаних фізичних процесів, що включає нейтронно-фізичні процеси ланцюгової реакції поділу, теплофізичні процеси теплопередачі та тепловиділення, а також гідродинамічні процеси циркуляції теплоносія. Математична основа моделі базується на системі диференціальних рівнянь у приватних похідних, що описують динаміку ключових параметрів реакторної установки. Для чисельної реалізації застосовано методи скінченних різниць та Рунге – Кутта четвертого порядку, що забезпечило високу точність розрахунків. Програмна реалізація виконана в середовищі MATLAB з використанням бібліотек Simulink для моделювання динамічних систем та Matplotlib для візуалізації результатів. Розроблений інтерактивний графічний інтерфейс дозволяє здійснювати оперативне керування параметрами моделювання та візуалізацію результатів у режимі реального часу. Валідація моделі проведена шляхом порівняння результатів моделювання з експлуатаційними даними діючих енергоблоків. Результати демонструють високу точність моделі – середнє відхилення розрахункових значень ключових параметрів не перевищує 2–3 %. Особливу цінність становить можливість моделювання аварійних ситуацій та перехідних режимів, що робить розроблений цифровий двійник ефективним інструментом для оптимізації експлуатаційних режимів, прогнозування поведінки реакторної установки, підготовки оперативного персоналу, відпрацювання дій у аварійних ситуаціях та проведення віртуальних експериментів. Розроблена модель може бути інтегрована з існуючими автоматизованими системами управління для створення єдиного інформаційно-керуючого простору енергоблоків атомних електростанцій.
- 16 December 2025
- Published by Zhytomyr Polytechnic State University in Технічна інженерія
- No. 2(96),p. 58-67
Open AccessРозробка інтегрованої моделі цифрового двійника для ефективної експлуатації енергоблоків АЕС
У статті представлено результати дослідження з розробки та впровадження інтегрованої моделі цифрового двійника енергоблоку атомної електростанції. Актуальність дослідження обумовлена потребою підвищення ефективності, безпеки та надійності експлуатації ядерних енергетичних установок в умовах цифровізації енергетики. Запропонована модель реалізує комплексне моделювання взаємопов’язаних фізичних процесів, що включає нейтронно-фізичні процеси ланцюгової реакції поділу, теплофізичні процеси теплопередачі та тепловиділення, а також гідродинамічні процеси циркуляції теплоносія. Математична основа моделі базується на системі диференціальних рівнянь у приватних похідних, що описують динаміку ключових параметрів реакторної установки. Для чисельної реалізації застосовано методи скінченних різниць та Рунге – Кутта четвертого порядку, що забезпечило високу точність розрахунків. Програмна реалізація виконана в середовищі MATLAB з використанням бібліотек Simulink для моделювання динамічних систем та Matplotlib для візуалізації результатів. Розроблений інтерактивний графічний інтерфейс дозволяє здійснювати оперативне керування параметрами моделювання та візуалізацію результатів у режимі реального часу. Валідація моделі проведена шляхом порівняння результатів моделювання з експлуатаційними даними діючих енергоблоків. Результати демонструють високу точність моделі – середнє відхилення розрахункових значень ключових параметрів не перевищує 2–3 %. Особливу цінність становить можливість моделювання аварійних ситуацій та перехідних режимів, що робить розроблений цифровий двійник ефективним інструментом для оптимізації експлуатаційних режимів, прогнозування поведінки реакторної установки, підготовки оперативного персоналу, відпрацювання дій у аварійних ситуаціях та проведення віртуальних експериментів. Розроблена модель може бути інтегрована з існуючими автоматизованими системами управління для створення єдиного інформаційно-керуючого простору енергоблоків атомних електростанцій.
- Open Access
- 9 July 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1(10),p. 31-39
Computer simulation of the development of the Сhornobyl nuclear power plant accident using an interactive simulator
The process of creating a mathematical model and an interactive computer simulator designed to reproduce the dynamics of the Chernobyl accident is considered. The main goal of the study is to identify the key physical factors that led to the catastrophic acceleration of the reactor, with the subsequent use of the modeling results for educational and research purposes. As part of the work, a comprehensive integrated model was implemented that covers neutron kinetics taking into account delayed neutrons, changes in reactivity due to the steam effect and movement of control rods, the balance of xenon-135 concentration, as well as the thermal hydraulic characteristics of the core. The simulation was implemented using numerical integration methods with an adaptive time step, which allowed us to reproduce the details of the accident process with high accuracy. The dynamics of parameters such as power, temperature, pressure, and rod position were visualized using a web library with an update rate of 60 frames per second. Verification of the model showed that the results correspond to historical data with an accuracy of over 93 % for the main parameters, including the moment of peak power and the values of temperature and pressure. Comparative analysis with available literature sources showed that the proposed approach has advantages over classical one-dimensional models that do not take into account the combined effect of several physical factors. The practical value of the development lies in creating an effective training tool for training nuclear power plant operational personnel, which allows analyzing critical scenarios, identifying effective intervention points and studying the consequences of erroneous actions. The limitation of the model is the lack of spatial distribution of parameters in the reactor and the simplification of thermohydraulic dependencies, which is planned to be taken into account in further research.
- 9 July 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1(10),p. 31-39
Open AccessComputer simulation of the development of the Сhornobyl nuclear power plant accident using an interactive simulator
The process of creating a mathematical model and an interactive computer simulator designed to reproduce the dynamics of the Chernobyl accident is considered. The main goal of the study is to identify the key physical factors that led to the catastrophic acceleration of the reactor, with the subsequent use of the modeling results for educational and research purposes. As part of the work, a comprehensive integrated model was implemented that covers neutron kinetics taking into account delayed neutrons, changes in reactivity due to the steam effect and movement of control rods, the balance of xenon-135 concentration, as well as the thermal hydraulic characteristics of the core. The simulation was implemented using numerical integration methods with an adaptive time step, which allowed us to reproduce the details of the accident process with high accuracy. The dynamics of parameters such as power, temperature, pressure, and rod position were visualized using a web library with an update rate of 60 frames per second. Verification of the model showed that the results correspond to historical data with an accuracy of over 93 % for the main parameters, including the moment of peak power and the values of temperature and pressure. Comparative analysis with available literature sources showed that the proposed approach has advantages over classical one-dimensional models that do not take into account the combined effect of several physical factors. The practical value of the development lies in creating an effective training tool for training nuclear power plant operational personnel, which allows analyzing critical scenarios, identifying effective intervention points and studying the consequences of erroneous actions. The limitation of the model is the lack of spatial distribution of parameters in the reactor and the simplification of thermohydraulic dependencies, which is planned to be taken into account in further research.
- Open Access
- 30 June 2023
- Published by Ukrainian Research and Design Institute of Building Materials and Products in European Science
- No. sge51-01,p. 186-199
IMPROVEMENTS TO THE AUTOMATED PROCESS CONTROL SYSTEM FOR A POWER UNIT BASED ON A DIGITAL TWIN
This paper examines an approach to improving the automated process control system of a power unit based on a digital twin. It justifies the feasibility of moving from traditional monitoring of current parameters to predictive monitoring, scenario modelli
- 30 June 2023
- Published by Ukrainian Research and Design Institute of Building Materials and Products in European Science
- No. sge51-01,p. 186-199
Open AccessIMPROVEMENTS TO THE AUTOMATED PROCESS CONTROL SYSTEM FOR A POWER UNIT BASED ON A DIGITAL TWIN
This paper examines an approach to improving the automated process control system of a power unit based on a digital twin. It justifies the feasibility of moving from traditional monitoring of current parameters to predictive monitoring, scenario modelli