Ehsan Shokrolahzade
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ehsan Shokrolahzade has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Marco Spirito
Delft University of Technology
4 shared publications - Faisal Ali Mubarak
VSL National Metrology Institute of the Netherlands, Delft, The Netherlands
2 shared publications - Luca Oberto
Istituto Nazionale di Ricerca Metrologica
2 shared publications - Alessandro Alocco
Department of Applied Science and Technology, Politecnico di Torino, Turin, Italy
1 shared publication - Andrea Celotto
Department of Applied Science and Technology, Politecnico di Torino, Turin, Italy
1 shared publication - Bernardo Galvano
Quantum Metrology and Nanotechnology Division, Istituto Nazionale di Ricerca Metrologica, Turin, Italy
1 shared publication
Latest Publications
- 28 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 74 (6) , 4989-5003
Experimental Characterization of Millimeter-Wave SiGe-Integrated Avalanche Noise Sources for 4 K Cryogenic Applications
Avalanche driven diodes have been traditionally used as electrical noise generator due to their capability of generating broadband random noise. Currently, no solutions have been reported to generate avalanche noise at cryogenic temperatures. This work represents a step toward addressing this gap. For the first time, we present the full characterization of two millimeter-wave noise sources (NSs) operating at cryogenic temperatures: the first based on the base-collector diode of an heterojunction bipolar transistor (HBT) driven into avalanche, while the second based on a p-i-n diode integrating the bias circuitry and the output attenuator. Both devices, fabricated using two different 130-nm silicon-germanium (SiGe) BiCMOS process and assessed as NSs at room temperature (RT), have now been demonstrated to operate reliably and efficiently for physical temperatures as low as 4.3 K. Both devices are measured over a complete cooling cycle with mid temperature points (i.e., 300, 70, 4.3) during cooling and warming cycle, to assess that no hysteresis or memory effect are present in their behavior. The reported excess noise ratio (ENR) of the HBT-based diode shows a maximum variation of about 1 and 0.5 dB for 2 and 4 mA bias currents, respectively, in the range of 1–40 GHz. For the same biasing ranges, the p-i-n NS showed a maximum variation of 2 dB at 30 GHz (on-chip attenuator included) resulting in a temperature sensitivity of about −0.007 dB/K. The reported results highlights the capability of such devices to realize a new class of integrated high performance cryogenic sources, opening the possibility to integrated in situ cryogenic calibrations.
- 28 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 74 (6) , 4989-5003
Experimental Characterization of Millimeter-Wave SiGe-Integrated Avalanche Noise Sources for 4 K Cryogenic Applications
Avalanche driven diodes have been traditionally used as electrical noise generator due to their capability of generating broadband random noise. Currently, no solutions have been reported to generate avalanche noise at cryogenic temperatures. This work represents a step toward addressing this gap. For the first time, we present the full characterization of two millimeter-wave noise sources (NSs) operating at cryogenic temperatures: the first based on the base-collector diode of an heterojunction bipolar transistor (HBT) driven into avalanche, while the second based on a p-i-n diode integrating the bias circuitry and the output attenuator. Both devices, fabricated using two different 130-nm silicon-germanium (SiGe) BiCMOS process and assessed as NSs at room temperature (RT), have now been demonstrated to operate reliably and efficiently for physical temperatures as low as 4.3 K. Both devices are measured over a complete cooling cycle with mid temperature points (i.e., 300, 70, 4.3) during cooling and warming cycle, to assess that no hysteresis or memory effect are present in their behavior. The reported excess noise ratio (ENR) of the HBT-based diode shows a maximum variation of about 1 and 0.5 dB for 2 and 4 mA bias currents, respectively, in the range of 1–40 GHz. For the same biasing ranges, the p-i-n NS showed a maximum variation of 2 dB at 30 GHz (on-chip attenuator included) resulting in a temperature sensitivity of about −0.007 dB/K. The reported results highlights the capability of such devices to realize a new class of integrated high performance cryogenic sources, opening the possibility to integrated in situ cryogenic calibrations.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 8008711
Full Two-Port S-Parameters at mK Temperatures: A Calibration Strategy and Uncertainty Budget
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 8008711
Open AccessFull Two-Port S-Parameters at mK Temperatures: A Calibration Strategy and Uncertainty Budget
- 18 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 73 (11) , 8956-8965
Test-Fixture Design Flow for Broadband Validation of CMOS Device Models up to (sub)mm-Waves
This work presents a structured, CAD-assisted design flow to realize broadband on-wafer calibration structures, validated in the prefabrication phase, and extract the intrinsic device response up to (sub)mm-waves. The strict requirements imposed by the design rule checks (DRCs) of 22 nm CMOS technology are incorporated during the design phase of the fixture by using a scripted connectable tile elements approach. The minimum dimension of a critical feature of the fixture is then identified using a newly defined metric based on the correspondence between the EM field distribution in the fixture versus a non-perturbed case of the same standard (STD) artifact. A simulation test bench environment, augmented with experimental data, is then used to add the uncertainties arising from three main error contributors: vector network analyzer (VNA) receiver noise, probe placement error, and calibration residual errors. Including these errors allows for the generation of pre-silicon numerical uncertainty bounds, which are benchmarked with experimental data using calibration quality metrics and device-level parameters. Measurement results ranging from 1 to 325 GHz are presented to demonstrate the validity of the proposed approach to establish the quality of on-wafer calibration approaches integrated in the back-end of line of Si-based technologies and to validate the compact model of CMOS devices up to (sub)mm-waves.
- 18 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 73 (11) , 8956-8965
Test-Fixture Design Flow for Broadband Validation of CMOS Device Models up to (sub)mm-Waves
This work presents a structured, CAD-assisted design flow to realize broadband on-wafer calibration structures, validated in the prefabrication phase, and extract the intrinsic device response up to (sub)mm-waves. The strict requirements imposed by the design rule checks (DRCs) of 22 nm CMOS technology are incorporated during the design phase of the fixture by using a scripted connectable tile elements approach. The minimum dimension of a critical feature of the fixture is then identified using a newly defined metric based on the correspondence between the EM field distribution in the fixture versus a non-perturbed case of the same standard (STD) artifact. A simulation test bench environment, augmented with experimental data, is then used to add the uncertainties arising from three main error contributors: vector network analyzer (VNA) receiver noise, probe placement error, and calibration residual errors. Including these errors allows for the generation of pre-silicon numerical uncertainty bounds, which are benchmarked with experimental data using calibration quality metrics and device-level parameters. Measurement results ranging from 1 to 325 GHz are presented to demonstrate the validity of the proposed approach to establish the quality of on-wafer calibration approaches integrated in the back-end of line of Si-based technologies and to validate the compact model of CMOS devices up to (sub)mm-waves.
- 10 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 73 (11) , 9058-9069
Thermo-Mechanical EM Models for Broadband Cryogenic VNA Calibration Including Numerical Uncertainties Down to 4.2 K
Increasing demand for cryogenic electronics aimed at quantum sensors and computing technologies asks for accurate and quantifiable calibration methods and techniques. In this work, we present a structured approach to generate the nominal RF responses of standard artifacts, enabling wideband vector network analyzer (VNA) calibration algorithms, i.e., short, open, load, and reciprocal (SOLR), at cryogenic temperatures. Moreover, we present an EM simulation strategy to generate the perturbations in the artifacts’ responses based on mechanical fabrication tolerances and calculate an equivalent RF response uncertainty. Both the nominal and perturbed standard responses are computed at (user defined) cryogenic temperatures, by combining thermo-mechanical responses with the electromagnetic solver. A circuit simulator-based measurement model (MM) is used to compute the uncertainties of the cryogenic setups used in this work. Error contributions arising from the propagation of VNA noise, switch nonidealities, calibration artifacts uncertainties, temperature fluctuations, and temperature gradient over the interconnects are included in the MM. For validation, measured results of a coaxial air transmission line at 77 K and 4.2 K are presented and compared with 3-D EM simulation predictions. Finally, the measurement uncertainties are detailed in a budget analysis describing the individual contributions.
- 10 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 73 (11) , 9058-9069
Thermo-Mechanical EM Models for Broadband Cryogenic VNA Calibration Including Numerical Uncertainties Down to 4.2 K
Increasing demand for cryogenic electronics aimed at quantum sensors and computing technologies asks for accurate and quantifiable calibration methods and techniques. In this work, we present a structured approach to generate the nominal RF responses of standard artifacts, enabling wideband vector network analyzer (VNA) calibration algorithms, i.e., short, open, load, and reciprocal (SOLR), at cryogenic temperatures. Moreover, we present an EM simulation strategy to generate the perturbations in the artifacts’ responses based on mechanical fabrication tolerances and calculate an equivalent RF response uncertainty. Both the nominal and perturbed standard responses are computed at (user defined) cryogenic temperatures, by combining thermo-mechanical responses with the electromagnetic solver. A circuit simulator-based measurement model (MM) is used to compute the uncertainties of the cryogenic setups used in this work. Error contributions arising from the propagation of VNA noise, switch nonidealities, calibration artifacts uncertainties, temperature fluctuations, and temperature gradient over the interconnects are included in the MM. For validation, measured results of a coaxial air transmission line at 77 K and 4.2 K are presented and compared with 3-D EM simulation predictions. Finally, the measurement uncertainties are detailed in a budget analysis describing the individual contributions.