Saiko Kino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Saiko Kino has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Yuji Matsuura
Graduate School of Biomedical Engineering, Tohoku University, 6-6-05 Aoba, Sendai 980-8579, Japan
4 shared publications - Hiroto Ito
Graduate School of Biomedical Engineering, Tohoku University, 6-6-05 Aoba, Sendai 980-8579, Japan
1 shared publication - Kiiko Aiba
Tohoku University, Graduate School of Engineering, Sendai, Japan
1 shared publication Kiriko Yoshioka
Tohoku Univ. (Japan)
1 shared publicationYuki Tanaka
Graduate School of Biomedical Engineering, Tohoku University, 6-6-05 Aoba, Aramaki, Aoba-ku, Sendai, Miyagi 980-8579
1 shared publication
Latest Publications
- Open Access
- 1 October 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (10) , 107001-12
Blood component analysis using mid-infrared photoacoustic spectroscopy based on ultrasound detection: glucose analysis trial
Blood component analysis plays an important role in the early detection of various diseases. Routine analysis is useful for health management but currently requires blood sampling, which is invasive, painful, and carries the risk of infection.1 Therefore, many attempts have been made to develop noninvasive methods for blood component analysis based on optical approaches, including fluorescence,2 Raman,3 and infrared spectroscopy.4 In benchmarking against alternative noninvasive modalities, fluorescence-based skin autofluorescence reflects the accumulation of advanced glycation end products and can be affected by endogenous fluorophores such as collagen, reducing measurement specificity.5 Raman spectroscopy provides high molecular specificity by detecting unique vibrational fingerprints. However, in the skin, the inherently weak Raman scattering cross-section leads to low signal intensity, necessitating the use of large-aperture optics; this method is further constrained by American National Standards Institute/International Electrotechnical Commission laser safety limits.6 Microwave and radio-frequency methods can achieve deeper penetration into tissue than optical techniques, but glucose-induced changes in dielectric properties are small and often overshadowed by larger variations due to hydration, temperature, and ionic composition, complicating calibration.7
- 1 October 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (10) , 107001-12
Open AccessBlood component analysis using mid-infrared photoacoustic spectroscopy based on ultrasound detection: glucose analysis trial
Blood component analysis plays an important role in the early detection of various diseases. Routine analysis is useful for health management but currently requires blood sampling, which is invasive, painful, and carries the risk of infection.1 Therefore, many attempts have been made to develop noninvasive methods for blood component analysis based on optical approaches, including fluorescence,2 Raman,3 and infrared spectroscopy.4 In benchmarking against alternative noninvasive modalities, fluorescence-based skin autofluorescence reflects the accumulation of advanced glycation end products and can be affected by endogenous fluorophores such as collagen, reducing measurement specificity.5 Raman spectroscopy provides high molecular specificity by detecting unique vibrational fingerprints. However, in the skin, the inherently weak Raman scattering cross-section leads to low signal intensity, necessitating the use of large-aperture optics; this method is further constrained by American National Standards Institute/International Electrotechnical Commission laser safety limits.6 Microwave and radio-frequency methods can achieve deeper penetration into tissue than optical techniques, but glucose-induced changes in dielectric properties are small and often overshadowed by larger variations due to hydration, temperature, and ionic composition, complicating calibration.7
- Open Access
Noninvasive Analysis of Biological Components Using Simplified Mid-Infrared Photothermal Deflection Spectroscopy
We developed a photothermal deflection spectroscopy (PTDS) system for the noninvasive analysis of biological tissue. This system detects heat induced by irradiation with pulse-modulated mid-infrared light as the deflection of a probe laser. The probe light is incident on the sensing element horizontal with respect to its contact surface with the sample. This setup simplifies the optical alignment compared to conventional systems, which require the probe laser to be totally reflected at the prism contact surface and aligned with the point of mid-infrared light irradiation. In this study, we measured the PTDS spectra of biological samples to determine the characteristic features of their infrared absorption. We also compared the measurement reproducibility of two configurations: a horizontal optical path and a total reflection optical path. The horizontal optical path showed greater measurement reproducibility than the total reflection optical path when performing intermittent measurements on the wrist.
Open AccessNoninvasive Analysis of Biological Components Using Simplified Mid-Infrared Photothermal Deflection Spectroscopy
We developed a photothermal deflection spectroscopy (PTDS) system for the noninvasive analysis of biological tissue. This system detects heat induced by irradiation with pulse-modulated mid-infrared light as the deflection of a probe laser. The probe light is incident on the sensing element horizontal with respect to its contact surface with the sample. This setup simplifies the optical alignment compared to conventional systems, which require the probe laser to be totally reflected at the prism contact surface and aligned with the point of mid-infrared light irradiation. In this study, we measured the PTDS spectra of biological samples to determine the characteristic features of their infrared absorption. We also compared the measurement reproducibility of two configurations: a horizontal optical path and a total reflection optical path. The horizontal optical path showed greater measurement reproducibility than the total reflection optical path when performing intermittent measurements on the wrist.
- 18 April 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10251, 102511U-102511U-3
Noninvasive measurement of blood glucose level using mid-infrared quantum cascade lasers
- 18 April 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10251, 102511U-102511U-3
Noninvasive measurement of blood glucose level using mid-infrared quantum cascade lasers
- Open Access
- 1 January 2011
- Published by Laser Society of Japan in The Review of Laser Engineering
- Vol. 39 (12) , 938-941
Infrared Spectral Measurement of Saline Concentration Using Attenuated-Total-Refl ection Probe Based on Hollow Optical Fiber
- 1 January 2011
- Published by Laser Society of Japan in The Review of Laser Engineering
- Vol. 39 (12) , 938-941
Open AccessInfrared Spectral Measurement of Saline Concentration Using Attenuated-Total-Refl ection Probe Based on Hollow Optical Fiber