Paola Milillo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Paola Milillo has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Giorgia Schiraldi
Department of Medical & Surgical Sciences, Section of Diagnostic Imaging, University of Foggia, 71122 Foggia, Italy
1 shared publication - Luca Macarini
Department of Medical & Surgical Sciences, Section of Diagnostic Imaging, University of Foggia, Viale Luigi Pinto n. 1, 71122 Foggia, Italy
1 shared publication - Luca Pio Stoppino
Department of Medical & Surgical Sciences, Section of Diagnostic Imaging, University of Foggia, Viale Luigi Pinto n. 1, 71122 Foggia, Italy
1 shared publication - Roberta Vinci
Department of Medical & Surgical Sciences, Section of Diagnostic Imaging, University of Foggia, Viale Luigi Pinto n. 1, 71122 Foggia, Italy
1 shared publication - Sara Saccone
Department of Medical and Surgical Sciences, Section of Diagnostic Imaging, University of Foggia, Foggia, Italy
1 shared publication - Stefano Piscone
Department of Medical & Surgical Sciences, Section of Diagnostic Imaging, University of Foggia, Viale Luigi Pinto n. 1, 71122 Foggia, Italy
1 shared publication
Latest Publications
- Open Access
- 13 July 2025
- Published by MDPI AG in Journal of Imaging
- Vol. 11 (7) , 236
Bone Mineral Density (BMD) Assessment Using Dual-Energy CT with Different Base Material Pairs (BMPs)
The assessment of bone mineral density (BMD) is essential for osteoporosis diagnosis. Dual-energy X-ray Absorptiometry (DXA) is the current gold standard, but it has limitations in evaluating trabecular bone and is susceptible to different artifacts. In this study we evaluate whether Dual-Energy Computed Tomography (DECT) can be defined as an alternative method for the assessment of BMD in a sample of postmenopausal patients undergoing oncological follow-up. In this study a retrospective analysis was conducted on 41 patients who had both DECT and DXA within six months. BMD values were extracted from DECT using five different base material pairs (BMPs) and compared with DXA measurements at the femoral neck. The calcium–fat pairing showed the strongest correlation with DXA-derived BMD (Spearman’s ρ = 0.797) and excellent reproducibility (ICC = 0.983). There was a strong and significant association between the DXA results and the various BPM measurements. These findings support the possibility of DECT in the precise and opportunistic evaluation of BMD changes when employing particular BMPs. This study showed how this technique can be a useful and effective substitute for conventional DXA, particularly when patients are in oncological follow-up using DECT, minimizing additional radiation exposure.
- 13 July 2025
- Published by MDPI AG in Journal of Imaging
- Vol. 11 (7) , 236
Open AccessBone Mineral Density (BMD) Assessment Using Dual-Energy CT with Different Base Material Pairs (BMPs)
The assessment of bone mineral density (BMD) is essential for osteoporosis diagnosis. Dual-energy X-ray Absorptiometry (DXA) is the current gold standard, but it has limitations in evaluating trabecular bone and is susceptible to different artifacts. In this study we evaluate whether Dual-Energy Computed Tomography (DECT) can be defined as an alternative method for the assessment of BMD in a sample of postmenopausal patients undergoing oncological follow-up. In this study a retrospective analysis was conducted on 41 patients who had both DECT and DXA within six months. BMD values were extracted from DECT using five different base material pairs (BMPs) and compared with DXA measurements at the femoral neck. The calcium–fat pairing showed the strongest correlation with DXA-derived BMD (Spearman’s ρ = 0.797) and excellent reproducibility (ICC = 0.983). There was a strong and significant association between the DXA results and the various BPM measurements. These findings support the possibility of DECT in the precise and opportunistic evaluation of BMD changes when employing particular BMPs. This study showed how this technique can be a useful and effective substitute for conventional DXA, particularly when patients are in oncological follow-up using DECT, minimizing additional radiation exposure.