Qingkun Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qingkun Fan has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Gang Liu
Cancer Center, Union Hospital, Tongji Medical College Huazhong University of Science and Technology Wuhan China
3 shared publications Kunyu Yang
Union Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology Cancer Center, No. 1277 Jiefang Avenue, Wuhan, Hubei, 430022, CHINA
3 shared publicationsSheng Zhang
Union Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology Cancer Center, No. 1277 Jiefang Avenue, Wuhan, Hubei, 430022, CHINA
3 shared publications- Xuanfeng Ding
Corewell Health William Beaumont University Hospital
3 shared publications Riao Dao
School of Physics and Technology, Wuhan University, No. 299, Bayi Road, Wuchang District, Wuhan, Hubei, 430072, CHINA
2 shared publications- Shuyang Dai
Wuhan University
2 shared publications
Latest Publications
- 9 June 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4) , 042003
Proton Therapy Treatment Planning via the Alternating Direction Method of Multipliers: A Tutorial Review
Inverse treatment planning is central to intensity-modulated proton therapy (IMPT), where high-quality dose distributions must be achieved under machine, biological, delivery-efficiency, and robustness constraints. The alternating direction method of multipliers (ADMM) is a flexible operator-splitting framework that is well suited to such structured optimization problems because it separates smooth dose-fidelity terms from nonsmooth constraints or regularizers. This tutorial review summarizes representative ADMM formulations for proton therapy treatment planning, including minimum monitor unit (MMU) optimization, linear energy transfer (LET) optimization, energy-layer sparsity, robust optimization, and spot sparsity for proton arc therapy. We also place these formulations in the broader context of radiation therapy optimization, compare them with alternative methods, report illustrative computation times from five matRad examples, and discuss practical limitations, including parameter sensitivity, nonconvex convergence issues, and barriers to clinical translation.
- 9 June 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4) , 042003
Proton Therapy Treatment Planning via the Alternating Direction Method of Multipliers: A Tutorial Review
Inverse treatment planning is central to intensity-modulated proton therapy (IMPT), where high-quality dose distributions must be achieved under machine, biological, delivery-efficiency, and robustness constraints. The alternating direction method of multipliers (ADMM) is a flexible operator-splitting framework that is well suited to such structured optimization problems because it separates smooth dose-fidelity terms from nonsmooth constraints or regularizers. This tutorial review summarizes representative ADMM formulations for proton therapy treatment planning, including minimum monitor unit (MMU) optimization, linear energy transfer (LET) optimization, energy-layer sparsity, robust optimization, and spot sparsity for proton arc therapy. We also place these formulations in the broader context of radiation therapy optimization, compare them with alternative methods, report illustrative computation times from five matRad examples, and discuss practical limitations, including parameter sensitivity, nonconvex convergence issues, and barriers to clinical translation.
- 2 September 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (18)
Bidirectional scan-based velocity scheduling algorithm for proton arc gantry with limited jerk
Objective. Spot-scanning proton arc therapy (SPArc) is an innovative planning and delivery framework for proton arc therapy that achieves conformal dose distribution via the rotating gantry. The clinical implementation of SPArc relies on efficient treatment delivery and smooth gantry rotation, with gantry velocity scheduling playing a crucial role in addressing this challenge. This study proposes a bidirectional scan-based gantry velocity scheduling algorithm, designated as BDSSPArc, to enhance the delivery efficiency and generate smooth gantry velocity profiles for SPArc plans concerning the mechanical and clinical requirements. Approach. For a given SPArc plan, BDSSPArc generates the gantry velocity profile by determining maximum feasible gantry velocities that allow sufficient time for irradiation and energy layer switch based on a bidirectional scan procedure. The profile with limited jerk (time derivative of acceleration) is then used to connect the velocities at the adjacent gantry angles. The SPArc delivery sequence model (DSMSPArc) was used as a benchmark. SPArc plans for nine clinical cases, including brain, liver, lung, prostate, and head & neck cancers, were utilized for the evaluation. The performance of BDSSPArc was evaluated based on the dynamic delivery time, the lost time (the difference between the dynamic delivery time and the fix beam delivery time), and the order of continuity of the gantry velocity profile. Main Results. Compared with DSMSPArc, BDSSPArc significantly enhances the delivery efficiency, reducing the average dynamic delivery time from 308.5 ± 10.0 s to 273.1 ± 18.5 s and the lost time from 48.1 ± 10.0 s to 12.6 ± 3.1 s. Meanwhile, it increases the smoothness of the gantry velocity profile. Significance. BDSSPArc is a novel gantry velocity scheduling algorithm for SPArc treatment delivery that enhances the delivery efficiency and generates smoother velocity profiles compared with DSMSPArc, offering a practical and optimized ingredient in SPArc planning.
- 2 September 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (18)
Bidirectional scan-based velocity scheduling algorithm for proton arc gantry with limited jerk
Objective. Spot-scanning proton arc therapy (SPArc) is an innovative planning and delivery framework for proton arc therapy that achieves conformal dose distribution via the rotating gantry. The clinical implementation of SPArc relies on efficient treatment delivery and smooth gantry rotation, with gantry velocity scheduling playing a crucial role in addressing this challenge. This study proposes a bidirectional scan-based gantry velocity scheduling algorithm, designated as BDSSPArc, to enhance the delivery efficiency and generate smooth gantry velocity profiles for SPArc plans concerning the mechanical and clinical requirements. Approach. For a given SPArc plan, BDSSPArc generates the gantry velocity profile by determining maximum feasible gantry velocities that allow sufficient time for irradiation and energy layer switch based on a bidirectional scan procedure. The profile with limited jerk (time derivative of acceleration) is then used to connect the velocities at the adjacent gantry angles. The SPArc delivery sequence model (DSMSPArc) was used as a benchmark. SPArc plans for nine clinical cases, including brain, liver, lung, prostate, and head & neck cancers, were utilized for the evaluation. The performance of BDSSPArc was evaluated based on the dynamic delivery time, the lost time (the difference between the dynamic delivery time and the fix beam delivery time), and the order of continuity of the gantry velocity profile. Main Results. Compared with DSMSPArc, BDSSPArc significantly enhances the delivery efficiency, reducing the average dynamic delivery time from 308.5 ± 10.0 s to 273.1 ± 18.5 s and the lost time from 48.1 ± 10.0 s to 12.6 ± 3.1 s. Meanwhile, it increases the smoothness of the gantry velocity profile. Significance. BDSSPArc is a novel gantry velocity scheduling algorithm for SPArc treatment delivery that enhances the delivery efficiency and generates smoother velocity profiles compared with DSMSPArc, offering a practical and optimized ingredient in SPArc planning.
- 17 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (14) , 14NT02
A novel energy layer optimization strategy based on machine specific delivery sequence for proton arc therapy
Objective. Due to the magnetic hysteresis effect, it normally takes more time to switch the energy layer upward compared to downward in proton arc therapy (PAT), e.g. 5.5 s for energy layer switching upwards and 0.7 s for energy layer switching downwards. Therefore, previous studies have focused on reducing the number of energy jumps (NEJ) as a main direction. However, it is possible to reduce the energy layer switching time, for instance, by using magnetic field feedback in the energy layer switching system (ELSS) of the proton therapy system (PTS), especially for small energy jumps. Thus, we propose a new energy selection optimization strategy to improve the treatment delivery efficiency based on a fast ELSS, which allows energy jumps within a pre-defined threshold energy layer optimization (ELO-EJT). Approach. The ELO-EJT algorithm is based on two sequential steps: ELO and plan-quality re-optimization. The ELO problem was solved using the proximal forward–backward splitting method. The optimization problem of plan-quality re-optimization was solved by the alternating direction method of multipliers. Eight clinical cases were tested on the open-source treatment planning system matRad (German Cancer Research Center DKFZ), assessing plan quality and treatment delivery efficiency to evaluate the ELO-EJT algorithm. Main results. The ELO-EJT algorithm could achieve similar plan quality compared with the spot-scanning proton arc therapy _seq algorithm, which is based on the energy layer sorting and re-distribution mechanisms. Meanwhile, it reduces the beam delivery time without the need to limit energy jumps. More specifically, it reduces BDT by 23.93 ± 4.12% (from 123.95 ± 11.94 s to 94.14 ± 8.82 s). Significance. A new ELO strategy could effectively reduce the treatment delivery time by minimizing the NEJ exceeding a threshold NEJ T , which paves the way for the clinical application of spot-scanning PAT.
- 17 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (14) , 14NT02
A novel energy layer optimization strategy based on machine specific delivery sequence for proton arc therapy
Objective. Due to the magnetic hysteresis effect, it normally takes more time to switch the energy layer upward compared to downward in proton arc therapy (PAT), e.g. 5.5 s for energy layer switching upwards and 0.7 s for energy layer switching downwards. Therefore, previous studies have focused on reducing the number of energy jumps (NEJ) as a main direction. However, it is possible to reduce the energy layer switching time, for instance, by using magnetic field feedback in the energy layer switching system (ELSS) of the proton therapy system (PTS), especially for small energy jumps. Thus, we propose a new energy selection optimization strategy to improve the treatment delivery efficiency based on a fast ELSS, which allows energy jumps within a pre-defined threshold energy layer optimization (ELO-EJT). Approach. The ELO-EJT algorithm is based on two sequential steps: ELO and plan-quality re-optimization. The ELO problem was solved using the proximal forward–backward splitting method. The optimization problem of plan-quality re-optimization was solved by the alternating direction method of multipliers. Eight clinical cases were tested on the open-source treatment planning system matRad (German Cancer Research Center DKFZ), assessing plan quality and treatment delivery efficiency to evaluate the ELO-EJT algorithm. Main results. The ELO-EJT algorithm could achieve similar plan quality compared with the spot-scanning proton arc therapy _seq algorithm, which is based on the energy layer sorting and re-distribution mechanisms. Meanwhile, it reduces the beam delivery time without the need to limit energy jumps. More specifically, it reduces BDT by 23.93 ± 4.12% (from 123.95 ± 11.94 s to 94.14 ± 8.82 s). Significance. A new ELO strategy could effectively reduce the treatment delivery time by minimizing the NEJ exceeding a threshold NEJ T , which paves the way for the clinical application of spot-scanning PAT.
- 10 February 2024
- Published by Wiley in Medical Physics
- Vol. 51 (8) , 5682-5692
First direct machine‐specific parameters incorporated in Spot‐scanning Proton Arc (SPArc) optimization algorithm
Background: Spot‐scanning Proton Arc (SPArc) has been of significant interest in recent years because of its superior plan quality. Currently, the primary focus of research and development is on deliverability and treatment efficiency.Purpose: To address the challenges in generating a deliverable and efficient SPArc plan for a proton therapy system with a massive gantry, we developed a novel SPArc optimization algorithm (SPArcDMPO) by directly incorporating the machine‐specific parameters such as gantry mechanical constraints and proton delivery sequence.Methods: SPArc delivery sequence model (DSMarc) was built based on the machine‐specific parameters of the prototype arc delivery system, IBA ProteusONE®, including mechanical constraint (maximum gantry speed, acceleration, and deceleration) and proton delivery sequence (energy and spot delivery sequence, and irradiation time). SPArcDMPO resamples and adjusts each control point's delivery speed based on the DSMarc calculation through the iterative approach. In SPArcDMPO, users could set a reasonable arc delivery time during the plan optimization, which aims to minimize the gantry momentum changes and improve the delivery efficiency. Ten cases were selected to test SPArcDMPO. Two kinds of SPArc plans were generated using the same planning objective functions: (1) original SPArc plan (SPArcoriginal); (2) SPArcDMPO plan with a user‐pre‐defined delivery time. Additionally, arc delivery sequence was simulated based on the DSMarc and was compared. Treatment delivery time was compared between SPArcoriginal and SPArcDMPO. Dynamic arc delivery time, the static irradiation time, and its corresponding time differential (time differential = dynamic arc delivery time—static irradiation time) were analyzed, respectively. The total gantry velocity change was accumulated throughout the treatment delivery.Results: With a similar plan quality, objective value, number of energy layers, and spots, both SPArcoriginal and SPArcDMPO plans could be delivered continuously within the ± 1 degree tolerance window. However, compared to the SPArcoriginal, the strategy of SPArcDMPO is able to reduce the time differential from 30.55 ± 11.42%(90 ± 32 s) to 14.67 ± 6.97%(42 ± 20 s), p < 0.01. Furthermore, the corresponding total variations of gantry velocity during dynamic arc delivery are mitigated (SPArcoriginal vs. SPArcDMPO) from 14.73 ± 9.14 degree/s to 4.28 ± 2.42 degree/s, p < 0.01. Consequently, the SPArcDMPO plans could minimize the gantry momentum change based on the clinical user's input compared to the SPArcoriginal plans, which could help relieve the mechanical challenge of accelerating or decelerating the massive proton gantry.Conclusions: For the first time, clinical users not only could generate a SPArc plan meeting the mechanical constraint of their proton system but also directly control the arc treatment speed and momentum changes of the gantry during the plan optimization process. This work paved the way for the routine clinical implementation of proton arc therapy in the treatment planning system.
- 10 February 2024
- Published by Wiley in Medical Physics
- Vol. 51 (8) , 5682-5692
First direct machine‐specific parameters incorporated in Spot‐scanning Proton Arc (SPArc) optimization algorithm
Background: Spot‐scanning Proton Arc (SPArc) has been of significant interest in recent years because of its superior plan quality. Currently, the primary focus of research and development is on deliverability and treatment efficiency.Purpose: To address the challenges in generating a deliverable and efficient SPArc plan for a proton therapy system with a massive gantry, we developed a novel SPArc optimization algorithm (SPArcDMPO) by directly incorporating the machine‐specific parameters such as gantry mechanical constraints and proton delivery sequence.Methods: SPArc delivery sequence model (DSMarc) was built based on the machine‐specific parameters of the prototype arc delivery system, IBA ProteusONE®, including mechanical constraint (maximum gantry speed, acceleration, and deceleration) and proton delivery sequence (energy and spot delivery sequence, and irradiation time). SPArcDMPO resamples and adjusts each control point's delivery speed based on the DSMarc calculation through the iterative approach. In SPArcDMPO, users could set a reasonable arc delivery time during the plan optimization, which aims to minimize the gantry momentum changes and improve the delivery efficiency. Ten cases were selected to test SPArcDMPO. Two kinds of SPArc plans were generated using the same planning objective functions: (1) original SPArc plan (SPArcoriginal); (2) SPArcDMPO plan with a user‐pre‐defined delivery time. Additionally, arc delivery sequence was simulated based on the DSMarc and was compared. Treatment delivery time was compared between SPArcoriginal and SPArcDMPO. Dynamic arc delivery time, the static irradiation time, and its corresponding time differential (time differential = dynamic arc delivery time—static irradiation time) were analyzed, respectively. The total gantry velocity change was accumulated throughout the treatment delivery.Results: With a similar plan quality, objective value, number of energy layers, and spots, both SPArcoriginal and SPArcDMPO plans could be delivered continuously within the ± 1 degree tolerance window. However, compared to the SPArcoriginal, the strategy of SPArcDMPO is able to reduce the time differential from 30.55 ± 11.42%(90 ± 32 s) to 14.67 ± 6.97%(42 ± 20 s), p < 0.01. Furthermore, the corresponding total variations of gantry velocity during dynamic arc delivery are mitigated (SPArcoriginal vs. SPArcDMPO) from 14.73 ± 9.14 degree/s to 4.28 ± 2.42 degree/s, p < 0.01. Consequently, the SPArcDMPO plans could minimize the gantry momentum change based on the clinical user's input compared to the SPArcoriginal plans, which could help relieve the mechanical challenge of accelerating or decelerating the massive proton gantry.Conclusions: For the first time, clinical users not only could generate a SPArc plan meeting the mechanical constraint of their proton system but also directly control the arc treatment speed and momentum changes of the gantry during the plan optimization process. This work paved the way for the routine clinical implementation of proton arc therapy in the treatment planning system.
- 22 December 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (1) , 015004
A novel planning framework for efficient spot-scanning proton arc therapy via particle swarm optimization (SPArc-particle swarm)
Objective. Delivery efficiency is the bottleneck of spot-scanning proton arc therapy (SPArc) because of the numerous energy layers (ELs) ascending switches. This study aims to develop a new algorithm to mitigate the need for EL ascending via water equivalent thickness (WET) sector selection followed by particle swarm optimization (SPArc-particle swarm). Approach. SPArc-particle swarm divided the full arc trajectory into the optimal sectors based on K-means clustering analysis of the relative mean WET. Within the sector, particle swarm optimization was used to minimize the total energy switch time, optimizing the energy selection integrated with the EL delivery sequence and relationship. This novel planning framework was implemented on the open-source platform matRad (Department of Medical Physics in Radiation Oncology, German Cancer Research Center-DKFZ). Three representative cases (brain, liver, and prostate cancer) were selected for testing purposes. Two kinds of plans were generated: SPArc_seq and SPArc-particle swarm. The plan quality and delivery efficiency were evaluated. Main results. With a similar plan quality, the delivery efficiency was significantly improved using SPArc-particle swarm compared to SPArc_seq. More specifically, it reduces the number of ELs ascending switching compared to the SPArc_seq (from 21 to 7 in the brain, from 21 to 5 in the prostate, from 21 to 6 in the liver), leading to a 16%–26% reduction of the beam delivery time (BDT) in the SPArc treatment. Significance. A novel planning framework, SPArc-particle swarm, could significantly improve the delivery efficiency, which paves the roadmap towards routine clinical implementation.
- 22 December 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (1) , 015004
A novel planning framework for efficient spot-scanning proton arc therapy via particle swarm optimization (SPArc-particle swarm)
Objective. Delivery efficiency is the bottleneck of spot-scanning proton arc therapy (SPArc) because of the numerous energy layers (ELs) ascending switches. This study aims to develop a new algorithm to mitigate the need for EL ascending via water equivalent thickness (WET) sector selection followed by particle swarm optimization (SPArc-particle swarm). Approach. SPArc-particle swarm divided the full arc trajectory into the optimal sectors based on K-means clustering analysis of the relative mean WET. Within the sector, particle swarm optimization was used to minimize the total energy switch time, optimizing the energy selection integrated with the EL delivery sequence and relationship. This novel planning framework was implemented on the open-source platform matRad (Department of Medical Physics in Radiation Oncology, German Cancer Research Center-DKFZ). Three representative cases (brain, liver, and prostate cancer) were selected for testing purposes. Two kinds of plans were generated: SPArc_seq and SPArc-particle swarm. The plan quality and delivery efficiency were evaluated. Main results. With a similar plan quality, the delivery efficiency was significantly improved using SPArc-particle swarm compared to SPArc_seq. More specifically, it reduces the number of ELs ascending switching compared to the SPArc_seq (from 21 to 7 in the brain, from 21 to 5 in the prostate, from 21 to 6 in the liver), leading to a 16%–26% reduction of the beam delivery time (BDT) in the SPArc treatment. Significance. A novel planning framework, SPArc-particle swarm, could significantly improve the delivery efficiency, which paves the roadmap towards routine clinical implementation.