Baoning Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Baoning Sun has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Siyuan Tan
Dalian Coherent Light Source and State Key Laboratory of Chemical Reaction Dynamics, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, People’s Republic of China
2 shared publications - Weiqing Zhang
Dalian Institute of Chemical Physics
2 shared publications - Xinmeng Li
Dalian Institute of Chemical Physics
2 shared publications - Bingbing Zhang
Institute of Advanced Light Source Facilities, Shenzhen 3 , 268 Zhenyuan Road, Shenzhen 518107
1 shared publication Jiandong Cai
Institute of Advanced Light Source Facilities 1 , 518107 Shenzhen
1 shared publication- Jiayue Yang
State Key Laboratory of Chemical Reaction Dynamics, Dalian Institute of Chemical Physics, Chinese Academy of Sciences 2 , Dalian 116023
1 shared publication
Latest Publications
- Open Access
- 1 December 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
Gravity compensation of bendable mirrors in Kirkpatrick–Baez systems with end-loss correction
Gravity-induced surface deviations in bendable mirrors degrade the performance of Kirkpatrick–Baez focusing systems at synchrotron and free-electron-laser beamlines. Conventional gravity compensation models ignore the inactive end length introduced by end clamping in four-roll benders. This omission leads to a systematic mismatch between predicted and measured surface shapes. This study develops an analytical model with end-loss correction within the Euler–Bernoulli beam framework for bendable mirrors. The model provides closed-form expressions for the required moments, the symmetric support forces, and the associated optimal dimensionless parameters. Finite element analysis verifies the predictions across representative geometries and load cases. With end loss included, the root-mean-square slope deviation decreases by about one order of magnitude to below 20 nrad, which meets the requirements for diffraction-limited focusing. This work establishes a robust framework for high-precision bendable mirror systems, with clear potential to reduce tuning cost and improve beamline optical performance.
- 1 December 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
Open AccessGravity compensation of bendable mirrors in Kirkpatrick–Baez systems with end-loss correction
Gravity-induced surface deviations in bendable mirrors degrade the performance of Kirkpatrick–Baez focusing systems at synchrotron and free-electron-laser beamlines. Conventional gravity compensation models ignore the inactive end length introduced by end clamping in four-roll benders. This omission leads to a systematic mismatch between predicted and measured surface shapes. This study develops an analytical model with end-loss correction within the Euler–Bernoulli beam framework for bendable mirrors. The model provides closed-form expressions for the required moments, the symmetric support forces, and the associated optimal dimensionless parameters. Finite element analysis verifies the predictions across representative geometries and load cases. With end loss included, the root-mean-square slope deviation decreases by about one order of magnitude to below 20 nrad, which meets the requirements for diffraction-limited focusing. This work establishes a robust framework for high-precision bendable mirror systems, with clear potential to reduce tuning cost and improve beamline optical performance.
- 14 August 2025
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 34 (9)
Shape Control of Piezoelectric Deformable Mirror by Deep Neural Network-Based Differential Evolution Algorithm
Shape control of multi-channel piezoelectric deformable mirrors presents significant challenges due to nonlinear effects and voltage constraints. This study proposes a deep neural network-based differential evolution (DNN-DE) algorithm to solve the inverse problem of shape control. A deep neural network (DNN) is trained on 1000 finite element simulations with randomly generated voltages accurately predicts mirror surface deformations that account for all fine local details. A global optimization differential evolution (DE) algorithm interacts with the trained DNN to minimize the root-mean-square (RMS) error function and determine the optimal control voltages for a given target shape. Three representative target surface shapes, Gaussian, elliptical, and arbitrary, are investigated. The corrected surfaces with sub-nanometer RMS errors satisfy diffraction-limited requirements with high adaptability and reproducibility. A comparison with the classical singular value decomposition (SVD) method based on response functions further validates the robustness of the proposed algorithm. This approach is applicable to various active and adaptive optics without accurate analytical models. Its architecture and training strategy are designed to support generalization implementations in free-electron laser and synchrotron radiation beamlines.
- 14 August 2025
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 34 (9)
Shape Control of Piezoelectric Deformable Mirror by Deep Neural Network-Based Differential Evolution Algorithm
Shape control of multi-channel piezoelectric deformable mirrors presents significant challenges due to nonlinear effects and voltage constraints. This study proposes a deep neural network-based differential evolution (DNN-DE) algorithm to solve the inverse problem of shape control. A deep neural network (DNN) is trained on 1000 finite element simulations with randomly generated voltages accurately predicts mirror surface deformations that account for all fine local details. A global optimization differential evolution (DE) algorithm interacts with the trained DNN to minimize the root-mean-square (RMS) error function and determine the optimal control voltages for a given target shape. Three representative target surface shapes, Gaussian, elliptical, and arbitrary, are investigated. The corrected surfaces with sub-nanometer RMS errors satisfy diffraction-limited requirements with high adaptability and reproducibility. A comparison with the classical singular value decomposition (SVD) method based on response functions further validates the robustness of the proposed algorithm. This approach is applicable to various active and adaptive optics without accurate analytical models. Its architecture and training strategy are designed to support generalization implementations in free-electron laser and synchrotron radiation beamlines.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Polarization diagnosis and transmission distortion calibration of the Dalian coherent light source
Polarized light serves as a fundamental tool in various scientific research, particularly in the study of chiral molecules and magnetic materials. For Free-electron Laser (FEL) sources, the Elliptical Polarized Undulator (EPU) has been extensively used as a tool to generate tunable polarized FEL. The accurate adjustment of the polarization state critically depends on the precise diagnosis of the polarization state. This work presents a Vacuum Ultraviolet (VUV) polarimeter that employs a reflection polarizer to determine the polarization state of the Dalian Coherent Light Source (DCLS), a VUV-FEL facility in Dalian, China. This instrument has been precisely installed on the DCLS-FEL2 beamline to measure the EPU-generated FEL pulses. The linear polarization angle was measured with an accuracy of ±1°, and a polarization degree of 95% was achieved at 10.2 eV photon energy. Furthermore, beamline transmission matrix calibration has been conducted to ensure precision of polarization state at downstream end-stations.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Polarization diagnosis and transmission distortion calibration of the Dalian coherent light source
Polarized light serves as a fundamental tool in various scientific research, particularly in the study of chiral molecules and magnetic materials. For Free-electron Laser (FEL) sources, the Elliptical Polarized Undulator (EPU) has been extensively used as a tool to generate tunable polarized FEL. The accurate adjustment of the polarization state critically depends on the precise diagnosis of the polarization state. This work presents a Vacuum Ultraviolet (VUV) polarimeter that employs a reflection polarizer to determine the polarization state of the Dalian Coherent Light Source (DCLS), a VUV-FEL facility in Dalian, China. This instrument has been precisely installed on the DCLS-FEL2 beamline to measure the EPU-generated FEL pulses. The linear polarization angle was measured with an accuracy of ±1°, and a polarization degree of 95% was achieved at 10.2 eV photon energy. Furthermore, beamline transmission matrix calibration has been conducted to ensure precision of polarization state at downstream end-stations.