Timi Malinen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Timi Malinen has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Olli-Pekka Nuuttila
Faculty of Sports and Health Sciences University of Jyväskylä Jyväskylä Finland
3 shared publications Arja Uusitalo
Department of Sports and Exercise Medicine, Clinicum University of Helsinki Helsinki Finland
2 shared publicationsHeikki Kyröläinen
Faculty of Sports and Health Sciences University of Jyväskylä Jyväskylä Finland
2 shared publicationsPekka Matomäki
Faculty of Sports and Health Sciences University of Jyväskylä Jyväskylä Finland
2 shared publicationsMimmi Iivari
Faculty of Sport and Health Sciences, University of Jyvaskyla, Jyvaskyla, Finland
1 shared publication- Pekka Matomäki
Faculty of Sport and Health Sciences, University of Jyvaskyla, Jyvaskyla, Finland
1 shared publication
Latest Publications
- Open Access
- 23 July 2026
- Published by Wiley in Scandinavian Journal of Medicine & Science in Sports
- Vol. 36 (7)
Determinants of Physiological Resilience Among Recreational‐To‐Competitive Endurance Runners
The aim of this study was to investigate (1) whether factors related to endurance performance are associated with physiological resilience in recreational‐to‐competitive runners, and (2) differences between recreational and competitive runners in physiological resilience. During three test days, 33 runners (15 competitive and 18 recreational) were tested for their peak fat oxidation, maximal blood lactate concentration (La max ) after maximal anaerobic running test (MART), maximal voluntary contraction (MVC) in isometric leg press, maximal oxygen uptake (VO 2max ), maximal speed of incremental test (sPeak), speeds at ventilatory thresholds (sVTs), running economy (RE), and physiological resilience. Physiological resilience was tested as deterioration of VO 2max , sPeak, VTs, and RE during and after ~2.5 h moderate‐intensity run at ~90% of VT1. Associations between other variables and physiological resilience were analyzed using Pearson's or sex‐adjusted partial correlations in the whole sample. Recreational runners had higher deterioration of VT1 ( p = 0.049), but lower deterioration in RE ( p = 0.042) than competitive runners. Lower decline in sPeak was associated with higher VO 2max ( r = 0.37, p = 0.04) and lower La max ( r = −0.37, p = 0.03). Lower decline in sVT1 was associated with higher VO 2max ( r = 0.37, p = 0.04), sVT2 ( r = 0.52, p = 0.002), sVT1 ( r = 0.48, p = 0.006), and sPeak ( r = 0.44, p = 0.01). Lower decline in RE was associated with worse RE ( r = −0.49, p = 0.004) and higher MVC ( r = −0.40, p = 0.02). Lower decline VO 2max was associated with worse RE ( r = 0.42, p = 0.02). It appears that physiological resilience is associated with multiple different physiological systems. High aerobic fitness and MVC of the leg extensors, and lower La max after MART may be related to better physiological resilience.
- 23 July 2026
- Published by Wiley in Scandinavian Journal of Medicine & Science in Sports
- Vol. 36 (7)
Open AccessDeterminants of Physiological Resilience Among Recreational‐To‐Competitive Endurance Runners
The aim of this study was to investigate (1) whether factors related to endurance performance are associated with physiological resilience in recreational‐to‐competitive runners, and (2) differences between recreational and competitive runners in physiological resilience. During three test days, 33 runners (15 competitive and 18 recreational) were tested for their peak fat oxidation, maximal blood lactate concentration (La max ) after maximal anaerobic running test (MART), maximal voluntary contraction (MVC) in isometric leg press, maximal oxygen uptake (VO 2max ), maximal speed of incremental test (sPeak), speeds at ventilatory thresholds (sVTs), running economy (RE), and physiological resilience. Physiological resilience was tested as deterioration of VO 2max , sPeak, VTs, and RE during and after ~2.5 h moderate‐intensity run at ~90% of VT1. Associations between other variables and physiological resilience were analyzed using Pearson's or sex‐adjusted partial correlations in the whole sample. Recreational runners had higher deterioration of VT1 ( p = 0.049), but lower deterioration in RE ( p = 0.042) than competitive runners. Lower decline in sPeak was associated with higher VO 2max ( r = 0.37, p = 0.04) and lower La max ( r = −0.37, p = 0.03). Lower decline in sVT1 was associated with higher VO 2max ( r = 0.37, p = 0.04), sVT2 ( r = 0.52, p = 0.002), sVT1 ( r = 0.48, p = 0.006), and sPeak ( r = 0.44, p = 0.01). Lower decline in RE was associated with worse RE ( r = −0.49, p = 0.004) and higher MVC ( r = −0.40, p = 0.02). Lower decline VO 2max was associated with worse RE ( r = 0.42, p = 0.02). It appears that physiological resilience is associated with multiple different physiological systems. High aerobic fitness and MVC of the leg extensors, and lower La max after MART may be related to better physiological resilience.
- Open Access
- 28 April 2026
- Published by Wiley in European Journal of Sport Science
- Vol. 26 (5) , e70178
Test‐Retest Reliability of Physiological Resilience During and After Prolonged Moderate‐Intensity Running in Well‐Trained Runners
In previous research, physiological resilience has been measured as deterioration of the physiological profile during prolonged exercise. This study aimed to evaluate the test–retest reliability of physiological resilience during prolonged moderate‐intensity running. Physiological profile of 26 well‐trained endurance runners (10 females) was tested in nonfatigued state as well as during and after two identical ∼2.5‐h long physiological resilience tests at ∼89% of VT1 (ventilatory threshold 1) speed within an average period of 13 days. Reliability was assessed with intraclass correlation coefficients (ICC), coefficient of variations (CV%), and typical errors (TE and TE%). Change in maximal speed achieved in the incremental test (sPeak) was the most reliable metric and showed good reliability (ICC: 0.81 and TE: 1.8). The drifts in running economy (RE) and the heart rate (HR) had moderate to good reliability in the second half of the trial (ICC: 0.52–0.80 and TE 1.7–2.4). The changes in maximal oxygen uptake (VO 2max ) and ventilatory thresholds (VTs) had poor reliability (ICC: 0.07–0.36 and TE: 3.5–4.6). However, the absolute values of these variables demonstrated good to excellent reliability in fatigued state (ICC > 0.83, TE% < 5.2%, and CV% < 4.1%) even though they significantly deteriorated. Determining changes in sPeak and drifts in RE and HR appears to be the most reliable method to measure physiological resilience. In contrast, measurement of the physiological profile remains reliable in fatigued state for every variable. Longer or more demanding protocols may be required to obtain greater reliability for deterioration of the physiological profile.
- 28 April 2026
- Published by Wiley in European Journal of Sport Science
- Vol. 26 (5) , e70178
Open AccessTest‐Retest Reliability of Physiological Resilience During and After Prolonged Moderate‐Intensity Running in Well‐Trained Runners
In previous research, physiological resilience has been measured as deterioration of the physiological profile during prolonged exercise. This study aimed to evaluate the test–retest reliability of physiological resilience during prolonged moderate‐intensity running. Physiological profile of 26 well‐trained endurance runners (10 females) was tested in nonfatigued state as well as during and after two identical ∼2.5‐h long physiological resilience tests at ∼89% of VT1 (ventilatory threshold 1) speed within an average period of 13 days. Reliability was assessed with intraclass correlation coefficients (ICC), coefficient of variations (CV%), and typical errors (TE and TE%). Change in maximal speed achieved in the incremental test (sPeak) was the most reliable metric and showed good reliability (ICC: 0.81 and TE: 1.8). The drifts in running economy (RE) and the heart rate (HR) had moderate to good reliability in the second half of the trial (ICC: 0.52–0.80 and TE 1.7–2.4). The changes in maximal oxygen uptake (VO 2max ) and ventilatory thresholds (VTs) had poor reliability (ICC: 0.07–0.36 and TE: 3.5–4.6). However, the absolute values of these variables demonstrated good to excellent reliability in fatigued state (ICC > 0.83, TE% < 5.2%, and CV% < 4.1%) even though they significantly deteriorated. Determining changes in sPeak and drifts in RE and HR appears to be the most reliable method to measure physiological resilience. In contrast, measurement of the physiological profile remains reliable in fatigued state for every variable. Longer or more demanding protocols may be required to obtain greater reliability for deterioration of the physiological profile.
- 1 January 2025
- Published by Human Kinetics in International Journal of Sports Physiology and Performance
- p. 1-9
Substituting Low-Intensity Endurance Exercise With High-Intensity Microintervals: Responses to Acute Exercise
Purpose: During very short (≤15 s) high-intensity (∼100% maximum rate of oxygen uptake [VO2]) intervals, defined here as microintervals, VO2 and lactate concentrations can remain near the first lactate threshold (LT1). However, no research has yet identified microinterval combinations that maintain acute responses entirely within the low-intensity zone below LT1, accounting for oscillations caused by pulsating power output. Methods: Thirteen endurance athletes cycled for four 45-minute exercises: continuous low-intensity exercise (CON; power: 88% LT1) and 3 microinterval exercises alternating 111% power associated to maximum rate of VO2 and ∼60 W, with cycles of 4–6, 7–23, and 10–20 s. Results: Compared with CON, heart rate and VO2 did not exceed LT1 more during microintervals (P ≥ .26, effect size ≤ 0.44), and rating of perceived exertion was greater only during 10–20 s (3.1 [0.8] vs 2.4 [0.7], P = .01). Blood lactate and mean respiratory exchange ratio did not differ between exercises (analysis of variance P ≥ .36). All mean responses of 4–26 and 7–23 were equivalent to CON (P ≤ .02). Oscillation of the examined variables during microintervals was largely greater than CON only for heart rate (>100% greater; P ≤ .001, effect size ≥ 1.7), while oscillation of VO2 was at most 25% greater (P ≥ .02, effect size ≤ 0.70). Conclusions: Microintervals could be classified as oscillating low-intensity exercises as they fulfill the traditional low-intensity criteria—responses of almost all internal variables did not exceed those of CON, not even fat oxidation. Microinterval exercises form a unique exercise class in which high-intensity muscular work blends with mild metabolic perturbation.
- 1 January 2025
- Published by Human Kinetics in International Journal of Sports Physiology and Performance
- p. 1-9
Substituting Low-Intensity Endurance Exercise With High-Intensity Microintervals: Responses to Acute Exercise
Purpose: During very short (≤15 s) high-intensity (∼100% maximum rate of oxygen uptake [VO2]) intervals, defined here as microintervals, VO2 and lactate concentrations can remain near the first lactate threshold (LT1). However, no research has yet identified microinterval combinations that maintain acute responses entirely within the low-intensity zone below LT1, accounting for oscillations caused by pulsating power output. Methods: Thirteen endurance athletes cycled for four 45-minute exercises: continuous low-intensity exercise (CON; power: 88% LT1) and 3 microinterval exercises alternating 111% power associated to maximum rate of VO2 and ∼60 W, with cycles of 4–6, 7–23, and 10–20 s. Results: Compared with CON, heart rate and VO2 did not exceed LT1 more during microintervals (P ≥ .26, effect size ≤ 0.44), and rating of perceived exertion was greater only during 10–20 s (3.1 [0.8] vs 2.4 [0.7], P = .01). Blood lactate and mean respiratory exchange ratio did not differ between exercises (analysis of variance P ≥ .36). All mean responses of 4–26 and 7–23 were equivalent to CON (P ≤ .02). Oscillation of the examined variables during microintervals was largely greater than CON only for heart rate (>100% greater; P ≤ .001, effect size ≥ 1.7), while oscillation of VO2 was at most 25% greater (P ≥ .02, effect size ≤ 0.70). Conclusions: Microintervals could be classified as oscillating low-intensity exercises as they fulfill the traditional low-intensity criteria—responses of almost all internal variables did not exceed those of CON, not even fat oxidation. Microinterval exercises form a unique exercise class in which high-intensity muscular work blends with mild metabolic perturbation.