Dirk Leiacker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dirk Leiacker has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- David Riehl
Integrated Electronic Systems Lab, Technische Universität Darmstadt, 64283 Darmstadt, Germany
2 shared publications - Felix Herbst
Measurement and Sensor Technology Group, Technische Universität Darmstadt, Darmstadt, Germany
2 shared publications - Julian Peters
Institute of Product Engineering, Karlsruhe Institute of Technology (KIT), 76131 Karlsruhe, Germany
2 shared publications - Klaus Hofmann
Integrated Electronic Systems Lab, Technische Universität Darmstadt, 64283 Darmstadt, Germany
2 shared publications - Mario Kupnik
Measurement and Sensor Technology Group, Technical University of Darmstadt, Darmstadt, Germany
2 shared publications - Sven Matthiesen
Karlsruhe Institute of Technology, Karlsruhe, Germany
2 shared publications
Latest Publications
- Open Access
The Role of Testing and Characterization in the Methodical Development of Sensor-Integrating Bolts for Multi-Axial Force Measurement
Sensor-integrating bolts offer a promising solution for in situ data acquisition by integrating sensory functions into existing machine elements. The standardized mechanical interfaces and performance must be maintained in order to ensure widespread use and retrofitting, which leads to a conflict of objectives between mechanical and sensory performance. The state of the art lacks multi-axial force-measuring bolts that meet these objectives. Therefore, we present a methodical approach that develops evolving prototypes of sensor-integrating bolts and applies testing activities to characterize the bolts’ performance and gain knowledge to further improve the prototypes. Strain gauges and a specifically developed electronics platform for data acquisition with a BLE interface are used. The prototypes are tested for axial and bending loads. Mechanical and sensory performance indicators are investigated, such as von Mises stress increase, linearity errors, hysteresis errors and sensitivity. The characterization results of the testing activities and the knowledge extracted from each iteration concerning aspects like strain gauge type and position or sensor body integration and their influence on the performance indicators are shown. Overall, the prototypes improved the linearity error from 3.3% to 1% (axial) and 3.7% to 0.1% (bending). The error is below 6% and sensitivities are around 10 µV/V/kN (axial) and 1 µV/V/Nm (bending). The integration of the measurement chain reduces the mechanical performance within a range of 1.3% to 24.6%, underlining the conflict of objectives. Measures for compensating the reduction need to be taken, such as increasing the bolt’s strength. Moreover, the measurements indicate that bending torques are superposed, even in axial load cases, making investigations of the effect on loadability necessary.
Open AccessThe Role of Testing and Characterization in the Methodical Development of Sensor-Integrating Bolts for Multi-Axial Force Measurement
Sensor-integrating bolts offer a promising solution for in situ data acquisition by integrating sensory functions into existing machine elements. The standardized mechanical interfaces and performance must be maintained in order to ensure widespread use and retrofitting, which leads to a conflict of objectives between mechanical and sensory performance. The state of the art lacks multi-axial force-measuring bolts that meet these objectives. Therefore, we present a methodical approach that develops evolving prototypes of sensor-integrating bolts and applies testing activities to characterize the bolts’ performance and gain knowledge to further improve the prototypes. Strain gauges and a specifically developed electronics platform for data acquisition with a BLE interface are used. The prototypes are tested for axial and bending loads. Mechanical and sensory performance indicators are investigated, such as von Mises stress increase, linearity errors, hysteresis errors and sensitivity. The characterization results of the testing activities and the knowledge extracted from each iteration concerning aspects like strain gauge type and position or sensor body integration and their influence on the performance indicators are shown. Overall, the prototypes improved the linearity error from 3.3% to 1% (axial) and 3.7% to 0.1% (bending). The error is below 6% and sensitivities are around 10 µV/V/kN (axial) and 1 µV/V/Nm (bending). The integration of the measurement chain reduces the mechanical performance within a range of 1.3% to 24.6%, underlining the conflict of objectives. Measures for compensating the reduction need to be taken, such as increasing the bolt’s strength. Moreover, the measurements indicate that bending torques are superposed, even in axial load cases, making investigations of the effect on loadability necessary.
- 14 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (9) , 1-4
Acoustic Energy Transfer for Integrated Sensor Systems
Powering embedded sensors in metal-enclosed environments poses significant challenges, such as structural constraints, battery dependence, and electromagnetic shielding. This work investigates using acoustic energy transfer (AET) as a viable approach and explores key factors influencing performance. A parametric study examines various parameters affecting energy transfer, which is followed by an experimental demonstration in a sensor-integrated bolt. Results indicate that electrical impedance matching greatly enhances power transfer but also alters the optimal transmission frequency. Elevated temperatures reduce the transducers' resonance frequency. This potentially impacts performance if only a single transducer is subjected to a temperature gradient, which can be caused by nearby machinery, exposure to hot industrial processes, or self-heating due to inefficiencies. Pure sine wave excitation increases power transfer up to 2.5 times over pulsewidth modulation at the expense of increased circuit complexity. Given that multiple parameters influence not only peak output power but also its frequency, active resonance tracking is essential for optimal energy transfer. Ultrasonic communication enables receiver-side frequency tracking, improving efficiency and adaptability in dynamic conditions. The final bolt-integrated setup achieves an output power of $\text{0.38 mW}$, demonstrating the feasibility of AET while also revealing size-related inefficiencies in embedded sensors.
- 14 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (9) , 1-4
Acoustic Energy Transfer for Integrated Sensor Systems
Powering embedded sensors in metal-enclosed environments poses significant challenges, such as structural constraints, battery dependence, and electromagnetic shielding. This work investigates using acoustic energy transfer (AET) as a viable approach and explores key factors influencing performance. A parametric study examines various parameters affecting energy transfer, which is followed by an experimental demonstration in a sensor-integrated bolt. Results indicate that electrical impedance matching greatly enhances power transfer but also alters the optimal transmission frequency. Elevated temperatures reduce the transducers' resonance frequency. This potentially impacts performance if only a single transducer is subjected to a temperature gradient, which can be caused by nearby machinery, exposure to hot industrial processes, or self-heating due to inefficiencies. Pure sine wave excitation increases power transfer up to 2.5 times over pulsewidth modulation at the expense of increased circuit complexity. Given that multiple parameters influence not only peak output power but also its frequency, active resonance tracking is essential for optimal energy transfer. Ultrasonic communication enables receiver-side frequency tracking, improving efficiency and adaptability in dynamic conditions. The final bolt-integrated setup achieves an output power of $\text{0.38 mW}$, demonstrating the feasibility of AET while also revealing size-related inefficiencies in embedded sensors.