Minglei Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Minglei Jiang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Dachi Zhang
Economic and Technological Research Institute of Jilin Electric Power Co., Ltd., Changchun 130022, China
2 shared publications - Hongbo Zou
College of Electrical Engineering and New Energy, China Three Gorges University, Yichang 443002, China
2 shared publications - Kerui Ma
Economic and Technological Research Institute of Jilin Electric Power Co., Ltd., Changchun 130022, China
1 shared publication - Qiushi Du
Economic and Technological Research Institute of Jilin Electric Power Co., Ltd., Changchun 130022, China
1 shared publication - Shengyao Shi
Economic and Technological Research Institute of Jilin Electric Power Co., Ltd., Changchun 130022, China
1 shared publication - Shiwei Qi
State Grid Jilin Electric Power Co., Ltd., Changchun 130021, China
1 shared publication
Latest Publications
- Open Access
A Coordinated Wind–Solar–Storage Planning Method Based on an Improved Bat Algorithm
With the widespread integration of renewable energy sources such as wind and solar power into power systems, their inherent unpredictability and fluctuations present significant challenges to grid stability and security. To address these issues, Battery Energy Storage Systems (BESSs) offer an effective means of enhancing renewable energy absorption and improving the overall system efficiency. This study proposes a coordinated planning method based on the improved bat algorithm (IBA) to tackle the challenges associated with integrating renewable energy into distribution networks. A bi-level optimization framework is introduced to coordinate the planning and operation of the distributed generation (DG) and BESS. The upper-level model focuses on selecting optimal sites and determining the capacity of wind turbines, photovoltaic arrays, and storage systems from an economic perspective. The lower-level model optimizes the curtailment of wind and solar energy and minimizes network losses based on the upper-level planning outcomes. Additionally, the lower-level model also coordinates the dispatch between renewable energy generation and storage systems to ensure the reliable operation of the system. To effectively solve this bi-level optimization model, we have improved the conventional bat algorithm. Simulation results show that the improved bat algorithm not only significantly enhances the convergence speed but also improves the voltage stability, with the photovoltaic utilization rate reaching 90.27% and the wind energy utilization rate reaching 92.18%. These results highlight the practical advantages and success of the proposed method in optimizing renewable energy configurations.
Open AccessA Coordinated Wind–Solar–Storage Planning Method Based on an Improved Bat Algorithm
With the widespread integration of renewable energy sources such as wind and solar power into power systems, their inherent unpredictability and fluctuations present significant challenges to grid stability and security. To address these issues, Battery Energy Storage Systems (BESSs) offer an effective means of enhancing renewable energy absorption and improving the overall system efficiency. This study proposes a coordinated planning method based on the improved bat algorithm (IBA) to tackle the challenges associated with integrating renewable energy into distribution networks. A bi-level optimization framework is introduced to coordinate the planning and operation of the distributed generation (DG) and BESS. The upper-level model focuses on selecting optimal sites and determining the capacity of wind turbines, photovoltaic arrays, and storage systems from an economic perspective. The lower-level model optimizes the curtailment of wind and solar energy and minimizes network losses based on the upper-level planning outcomes. Additionally, the lower-level model also coordinates the dispatch between renewable energy generation and storage systems to ensure the reliable operation of the system. To effectively solve this bi-level optimization model, we have improved the conventional bat algorithm. Simulation results show that the improved bat algorithm not only significantly enhances the convergence speed but also improves the voltage stability, with the photovoltaic utilization rate reaching 90.27% and the wind energy utilization rate reaching 92.18%. These results highlight the practical advantages and success of the proposed method in optimizing renewable energy configurations.
- Open Access
Research on an Active Distribution Network Planning Strategy Considering Diversified Flexible Resource Allocation
When planning distributed intelligent power distribution networks, it is necessary to take into account the interests of various distributed generation (DG) operators and power supply enterprises, thereby diversifying and complicating planning models. Additionally, the integration of a high proportion of distributed resources has triggered a transformation in the power flow pattern of active distribution networks, shifting from the traditional unidirectional flow mode to a bidirectional interactive mode. The intermittent and fluctuating operation modes of distributed photovoltaic and wind power generation have also increased the difficulty of distribution network planning. To address the aforementioned challenges, this paper proposes an active distribution network planning strategy that considers the allocation of diverse flexible resources, exploring scheduling flexibility from both the power supply side and the load side. Firstly, a bi-level optimization model integrating planning and operation is constructed, where the upper-level model determines the optimal capacity of investment and construction equipment, and the lower-level model formulates an economic dispatching scheme. Through iterative solving of the upper and lower levels, the final planning strategy is determined. Meanwhile, to reduce the complexity of problem-solving, this paper employs an improved PSO-CS hybrid algorithm for iterative optimization. Finally, the effectiveness and feasibility of the proposed algorithm are demonstrated through validation using an improved IEEE-33-bus test system. Compared with conventional algorithms, the convergence speed of the method proposed in this paper can be improved by up to 21.4%, and the total investment cost can be reduced by up to 3.26%.
Open AccessResearch on an Active Distribution Network Planning Strategy Considering Diversified Flexible Resource Allocation
When planning distributed intelligent power distribution networks, it is necessary to take into account the interests of various distributed generation (DG) operators and power supply enterprises, thereby diversifying and complicating planning models. Additionally, the integration of a high proportion of distributed resources has triggered a transformation in the power flow pattern of active distribution networks, shifting from the traditional unidirectional flow mode to a bidirectional interactive mode. The intermittent and fluctuating operation modes of distributed photovoltaic and wind power generation have also increased the difficulty of distribution network planning. To address the aforementioned challenges, this paper proposes an active distribution network planning strategy that considers the allocation of diverse flexible resources, exploring scheduling flexibility from both the power supply side and the load side. Firstly, a bi-level optimization model integrating planning and operation is constructed, where the upper-level model determines the optimal capacity of investment and construction equipment, and the lower-level model formulates an economic dispatching scheme. Through iterative solving of the upper and lower levels, the final planning strategy is determined. Meanwhile, to reduce the complexity of problem-solving, this paper employs an improved PSO-CS hybrid algorithm for iterative optimization. Finally, the effectiveness and feasibility of the proposed algorithm are demonstrated through validation using an improved IEEE-33-bus test system. Compared with conventional algorithms, the convergence speed of the method proposed in this paper can be improved by up to 21.4%, and the total investment cost can be reduced by up to 3.26%.