Dianlong Ge
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dianlong Ge has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Yannan Chu
Hefei Institutes of Physical Science, Chinese Academy of Sciences
5 shared publications Yue Liu
Hefei Cancer Hospital of CAS, Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology
4 shared publications- Chaoqun Huang
Hefei Institutes of Physical Science, Chinese Academy of Sciences
3 shared publications - Chengyin Shen
Hefei Institutes of Physical Science, Chinese Academy of Sciences
3 shared publications Jijuan Zhou
Hefei Cancer Hospital of CAS, Institute of Health and Medical Technology
3 shared publicationsXiangxue Zheng
Hefei Cancer Hospital of CAS, Institute of Health and Medical Technology
3 shared publications
Latest Publications
- 18 May 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (21) , 15455-15466
Rapid and Accurate Diagnosis of Bacterial Infections via Profiling of Metabolic Volatile Organic Compounds Using Proton Transfer Reaction Mass Spectrometry
Bacterial infections have become the second leading cause of death worldwide, and antimicrobial resistance (AMR) is a major factor contributing to treatment failure. Rapid and accurate bacterial identification (ID) and antibiotic susceptibility testing (AST) are critical for improving patient outcomes and controlling the spread of resistant strains. In this study, we developed a novel, rapid, and accurate diagnostic method for bacterial infections based on metabolic volatile organic compounds (VOCs). First, we performed untargeted profiling of metabolic VOCs from 9 clinically prevalent pathogens (Escherichia coli, Klebsiella pneumoniae, Enterobacter cloacae, Pseudomonas aeruginosa, Acinetobacter baumannii, Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecalis, and Enterococcus faecium) using proton transfer reaction mass spectrometry (PTR-MS). Notably, all 10 species (including the culture medium control) could be successfully distinguished using only four VOCs: isovaleraldehyde, methanethiol, acetaldehyde, and dimethyl disulfide. The entire ID workflow only takes 3 h, achieving 98.0% accuracy. And then, we established a phenotypic AST method leveraging bacterial activity-related characteristic VOCs (ARC-VOCs). Testing the susceptibility of these 9 pathogens to different antibiotics achieved 99.1% accuracy (455 bacterial-antibiotic combination), with a turnaround time of 3–4 h. In summary, this metabolic VOC-based method enables bacterial infection diagnosis (ID + AST) within 6–7 h. It cuts the diagnostic time of the widely used clinical platform VITEK 2 by more than 50%, while maintaining high accuracy. This approach holds promise for guiding clinicians to develop timely personalized treatment regimens and curbing the transmission of drug-resistant bacterial strains.
- 18 May 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (21) , 15455-15466
Rapid and Accurate Diagnosis of Bacterial Infections via Profiling of Metabolic Volatile Organic Compounds Using Proton Transfer Reaction Mass Spectrometry
Bacterial infections have become the second leading cause of death worldwide, and antimicrobial resistance (AMR) is a major factor contributing to treatment failure. Rapid and accurate bacterial identification (ID) and antibiotic susceptibility testing (AST) are critical for improving patient outcomes and controlling the spread of resistant strains. In this study, we developed a novel, rapid, and accurate diagnostic method for bacterial infections based on metabolic volatile organic compounds (VOCs). First, we performed untargeted profiling of metabolic VOCs from 9 clinically prevalent pathogens (Escherichia coli, Klebsiella pneumoniae, Enterobacter cloacae, Pseudomonas aeruginosa, Acinetobacter baumannii, Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecalis, and Enterococcus faecium) using proton transfer reaction mass spectrometry (PTR-MS). Notably, all 10 species (including the culture medium control) could be successfully distinguished using only four VOCs: isovaleraldehyde, methanethiol, acetaldehyde, and dimethyl disulfide. The entire ID workflow only takes 3 h, achieving 98.0% accuracy. And then, we established a phenotypic AST method leveraging bacterial activity-related characteristic VOCs (ARC-VOCs). Testing the susceptibility of these 9 pathogens to different antibiotics achieved 99.1% accuracy (455 bacterial-antibiotic combination), with a turnaround time of 3–4 h. In summary, this metabolic VOC-based method enables bacterial infection diagnosis (ID + AST) within 6–7 h. It cuts the diagnostic time of the widely used clinical platform VITEK 2 by more than 50%, while maintaining high accuracy. This approach holds promise for guiding clinicians to develop timely personalized treatment regimens and curbing the transmission of drug-resistant bacterial strains.
- 29 March 2026
- Published by Elsevier in Information Fusion
- Vol. 133
M3Net: A macro → meso → micro clinical-inspired hierarchical 3D network for pulmonary nodule classification
- 29 March 2026
- Published by Elsevier in Information Fusion
- Vol. 133
M3Net: A macro → meso → micro clinical-inspired hierarchical 3D network for pulmonary nodule classification
- 19 March 2026
- Published by Wiley in Expert Systems
- Vol. 43 (5)
Bilateral Edge‐Augmented Recurrent Horizontal Feature‐Shift Aggregation Network for Tooth Instance Segmentation With FDI ‐Based Numbering
Tooth instance segmentation in panoramic radiographs is crucial for computer‐aided dental diagnosis, yet remains challenging due to low contrast, structural similarity and the coexistence of permanent and deciduous teeth. In this paper, we propose BEHA‐Net, a Bilateral Edge‐Augmented Recurrent Horizontal Feature‐Shift Aggregation Network for joint tooth instance segmentation and Fédération Dentaire Internationale (FDI)‐compliant tooth numbering. BEHA‐Net integrates two key components: (1) a recurrent horizontal feature‐shift aggregation (HFA) module that captures cross‐tooth contextual correlations via leveraging the horizontal arrangement topology of dental arches and aggregating multi‐scale dependencies across adjacent and non‐adjacent teeth; and (2) a bilateral edge‐augmented (BEA) module that refines boundary representations by edge detail enhancement and noise suppression. Extensive experiments on the Tufts and O 2 PR benchmarks demonstrate the superiority of our method over existing approaches.
- 19 March 2026
- Published by Wiley in Expert Systems
- Vol. 43 (5)
Bilateral Edge‐Augmented Recurrent Horizontal Feature‐Shift Aggregation Network for Tooth Instance Segmentation With FDI ‐Based Numbering
Tooth instance segmentation in panoramic radiographs is crucial for computer‐aided dental diagnosis, yet remains challenging due to low contrast, structural similarity and the coexistence of permanent and deciduous teeth. In this paper, we propose BEHA‐Net, a Bilateral Edge‐Augmented Recurrent Horizontal Feature‐Shift Aggregation Network for joint tooth instance segmentation and Fédération Dentaire Internationale (FDI)‐compliant tooth numbering. BEHA‐Net integrates two key components: (1) a recurrent horizontal feature‐shift aggregation (HFA) module that captures cross‐tooth contextual correlations via leveraging the horizontal arrangement topology of dental arches and aggregating multi‐scale dependencies across adjacent and non‐adjacent teeth; and (2) a bilateral edge‐augmented (BEA) module that refines boundary representations by edge detail enhancement and noise suppression. Extensive experiments on the Tufts and O 2 PR benchmarks demonstrate the superiority of our method over existing approaches.
- 7 November 2025
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 25 (1) , 109-118
Regulating Energy Metabolism to Induce the Release of VOC Biomarkers in Lung Cancer Cells
Early diagnosis of lung cancer is critical for improving patient outcomes. Noninvasive detection techniques based on volatile organic compounds (VOCs) are gaining attention due to their convenience and low risk. This study innovatively explores the application of dichloroacetate (DCA), a multifunctional small molecule, in lung cancer diagnosis by analyzing DCA-induced alterations in VOCs released from normal lung cells (BEAS-2B) and lung cancer cells (PC-9) using solid-phase microextraction coupled with gas chromatography-mass spectrometry (SPME-GC-MS). A DCA concentration of 5 mmol/L was selected to minimize adverse effects on normal cells. Results revealed that DCA induced distinct VOC profiles in normal and cancer cells, suggesting differential metabolic regulation. Concentration-gradient experiments demonstrated that 2-methyl-2-propanol release increased with DCA concentration in both cell types, but cancer cells responded only at higher concentrations. Acetoin level in cancer cells increased with DCA concentration, which was absent in normal cells. Similar results were observed in other lung cancer cell lines (A549 and NCI-H460), confirming reproducible DCA-induced VOC patterns. This study proposes a novel strategy combining DCA intervention with SPME-GC-MS to amplify cancer-specific VOC signatures, providing a promising foundation for breath-based early screening of lung cancer. The findings highlight the potential of metabolic modulation in enhancing noninvasive diagnostic technologies.
- 7 November 2025
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 25 (1) , 109-118
Regulating Energy Metabolism to Induce the Release of VOC Biomarkers in Lung Cancer Cells
Early diagnosis of lung cancer is critical for improving patient outcomes. Noninvasive detection techniques based on volatile organic compounds (VOCs) are gaining attention due to their convenience and low risk. This study innovatively explores the application of dichloroacetate (DCA), a multifunctional small molecule, in lung cancer diagnosis by analyzing DCA-induced alterations in VOCs released from normal lung cells (BEAS-2B) and lung cancer cells (PC-9) using solid-phase microextraction coupled with gas chromatography-mass spectrometry (SPME-GC-MS). A DCA concentration of 5 mmol/L was selected to minimize adverse effects on normal cells. Results revealed that DCA induced distinct VOC profiles in normal and cancer cells, suggesting differential metabolic regulation. Concentration-gradient experiments demonstrated that 2-methyl-2-propanol release increased with DCA concentration in both cell types, but cancer cells responded only at higher concentrations. Acetoin level in cancer cells increased with DCA concentration, which was absent in normal cells. Similar results were observed in other lung cancer cell lines (A549 and NCI-H460), confirming reproducible DCA-induced VOC patterns. This study proposes a novel strategy combining DCA intervention with SPME-GC-MS to amplify cancer-specific VOC signatures, providing a promising foundation for breath-based early screening of lung cancer. The findings highlight the potential of metabolic modulation in enhancing noninvasive diagnostic technologies.
- 25 July 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (33) , 17962-17969
Investigation of Characteristic Volatile Organic Compounds in Esophageal Cancer Organoids by Mass Spectrometry
Volatilomics, an emerging field in the study of noninvasive biomarkers, holds significant promise for identifying esophageal cancer (EC) through the detection of volatile organic compounds (VOCs). This study investigates common characteristic VOCs of EC cells by analyzing VOCs from three-dimensional organoid and spheroid models as well as two-dimensional monolayer cultures. The VOC profiles were measured by using solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) in an untargeted approach. In the organoid, spheroid, and monolayer culture models, 21, 9, and 8 metabolically differential VOCs were identified between EC and normal esophageal (NE) cells, respectively. Correlation analysis across these three models revealed a shared characteristic VOC of EC: ethyl 2-methylbutyrate. This VOC was markedly increased in EC, demonstrating excellent diagnostic potential with an area under the curve (AUC) ranging from 0.93 to 0.99. Furthermore, transcriptomic data analysis of EC and NE tissues revealed the upregulation of protein degradation and absorption in EC tissues, supporting the hypothesis that ethyl 2-methylbutyrate arises from abnormalities within this metabolic pathway. This study not only supplies potential VOC biomarkers for EC identification but also provides a scientific basis for further elucidating the biochemical mechanisms underlying EC metabolic disturbances, potentially facilitating the gaseous biopsy technique development for EC diagnosis.
- 25 July 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (33) , 17962-17969
Investigation of Characteristic Volatile Organic Compounds in Esophageal Cancer Organoids by Mass Spectrometry
Volatilomics, an emerging field in the study of noninvasive biomarkers, holds significant promise for identifying esophageal cancer (EC) through the detection of volatile organic compounds (VOCs). This study investigates common characteristic VOCs of EC cells by analyzing VOCs from three-dimensional organoid and spheroid models as well as two-dimensional monolayer cultures. The VOC profiles were measured by using solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) in an untargeted approach. In the organoid, spheroid, and monolayer culture models, 21, 9, and 8 metabolically differential VOCs were identified between EC and normal esophageal (NE) cells, respectively. Correlation analysis across these three models revealed a shared characteristic VOC of EC: ethyl 2-methylbutyrate. This VOC was markedly increased in EC, demonstrating excellent diagnostic potential with an area under the curve (AUC) ranging from 0.93 to 0.99. Furthermore, transcriptomic data analysis of EC and NE tissues revealed the upregulation of protein degradation and absorption in EC tissues, supporting the hypothesis that ethyl 2-methylbutyrate arises from abnormalities within this metabolic pathway. This study not only supplies potential VOC biomarkers for EC identification but also provides a scientific basis for further elucidating the biochemical mechanisms underlying EC metabolic disturbances, potentially facilitating the gaseous biopsy technique development for EC diagnosis.
- 9 July 2025
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 24 (8) , 4215-4226
Gas Biopsy for Pan-Cancer Mice Early Screening by Untargeted Mass Spectrometry Analysis of Metabolic VOCs
Early cancer detection is crucial for improving cure and survival rates. Pan-cancer detection technology enables simultaneous screening for multiple cancer types, representing a significant advancement in cancer diagnosis. Recent biomedical research suggests that cancer may function as a metabolic disorder, underscoring the importance of multiomics, particularly metabolomics. Volatile organic compounds (VOCs) in metabolomics provide noninvasive methods for early disease screening. However, a reliable strategy for VOC analysis in early pan-cancer detection is currently lacking. In this study, we established a N-Nitrosodiethylamine (DEN)-ethanol induction pan-cancer mouse model to longitudinally monitor metabolomic samples (urine, feces, and odor) for VOCs throughout the entire tumor growth process. We employed headspace solid-phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) technology for untargeted tracking and profiling of tumor growth. Through statistical analysis, we identified characteristic metabolites from different metabolomic samples and determined their corresponding early screening time points. These VOCs demonstrated excellent performance in distinguishing tumor development and assessing differences between tumor and healthy groups in validation analyses. This study emphasizes the potential of VOCs in noninvasive whole cancer screening and early diagnosis, providing a fundamental reference for VOCs based gas biopsy experiments in preclinical stages, and demonstrating the concept of early tumor detection.
- 9 July 2025
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 24 (8) , 4215-4226
Gas Biopsy for Pan-Cancer Mice Early Screening by Untargeted Mass Spectrometry Analysis of Metabolic VOCs
Early cancer detection is crucial for improving cure and survival rates. Pan-cancer detection technology enables simultaneous screening for multiple cancer types, representing a significant advancement in cancer diagnosis. Recent biomedical research suggests that cancer may function as a metabolic disorder, underscoring the importance of multiomics, particularly metabolomics. Volatile organic compounds (VOCs) in metabolomics provide noninvasive methods for early disease screening. However, a reliable strategy for VOC analysis in early pan-cancer detection is currently lacking. In this study, we established a N-Nitrosodiethylamine (DEN)-ethanol induction pan-cancer mouse model to longitudinally monitor metabolomic samples (urine, feces, and odor) for VOCs throughout the entire tumor growth process. We employed headspace solid-phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) technology for untargeted tracking and profiling of tumor growth. Through statistical analysis, we identified characteristic metabolites from different metabolomic samples and determined their corresponding early screening time points. These VOCs demonstrated excellent performance in distinguishing tumor development and assessing differences between tumor and healthy groups in validation analyses. This study emphasizes the potential of VOCs in noninvasive whole cancer screening and early diagnosis, providing a fundamental reference for VOCs based gas biopsy experiments in preclinical stages, and demonstrating the concept of early tumor detection.