Jianwei Lai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jianwei Lai has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Aiguo Song
Southeast University
12 shared publications - Huijun Li
Southeast University
7 shared publications - Jiajin Wang
State Key Laboratory of Digital Medical Engineering, School of Instrument Science and Engineering, Southeast University, Nanjing, China
5 shared publications - Baoguo Xu
Southeast University
4 shared publications - Ye Li
Southeast University
4 shared publications - Ye Lu
School of Instrument Science and Engineering, Southeast University, Nanjing, China
4 shared publications
Latest Publications
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (12) , 14892-14899
A Self-Aligning Hand Exoskeleton for Virtual Haptic Interaction Based on Direct Drive and Human-Robot Kinematic Matching
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (12) , 14892-14899
A Self-Aligning Hand Exoskeleton for Virtual Haptic Interaction Based on Direct Drive and Human-Robot Kinematic Matching
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (11) , 12607-12614
Multi-Skill Learning-Based Variable Stiffness Control for Upper-Limb Rehabilitation Robot
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (11) , 12607-12614
Multi-Skill Learning-Based Variable Stiffness Control for Upper-Limb Rehabilitation Robot
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (10) , 11354-11361
Foldable Pouch Motor for Wearable Upper Limb Assistance and Rehabilitation
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (10) , 11354-11361
Foldable Pouch Motor for Wearable Upper Limb Assistance and Rehabilitation
- Open Access
- 29 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 2703-2716
Human-in-the-Loop Control Framework for Robot-Mediated Error Augmentation Training Based on Muscle Synergy Assessment
Robot-mediated error augmentation (EA) offers a promising paradigm for enhancing motor adaptation by amplifying movement errors rather than compensating for them. However, integrating EA into human-in-the-loop (HITL) control systems remains challenging. This difficulty arises from the lack of performance metrics that reflect neuromuscular adaptation and the limited ability to efficiently adapt control parameters to user-specific motor strategies. To address these challenges, we propose a HITL control framework that leverages muscle synergy analysis to guide the personalization of EA intensity. A synergy-based performance metric was designed to quantify motor adaptation by measuring structural similarity across muscle synergies. This metric served as the optimization objective for a Gaussian process-based Bayesian algorithm, which adaptively tuned the EA gain based on individual responses. An 8-day study involving ten healthy subjects performing non-dominant limb reaching tasks validated the proposed framework. The experimental group achieved significantly greater reductions in trajectory deviation than the control group, alongside robust within-group improvements (p < 0.01) and positive inter-group trends in muscle synergy similarities (gw,gc). These results demonstrate reliable convergence of the optimization process, robust inter-subject adaptability, and the effectiveness of the synergy metric in capturing adaptation. Overall, the findings highlight the potential of the proposed framework as a foundational tool for adaptive motor training in human–robot interaction systems.
- 29 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 2703-2716
Open AccessHuman-in-the-Loop Control Framework for Robot-Mediated Error Augmentation Training Based on Muscle Synergy Assessment
Robot-mediated error augmentation (EA) offers a promising paradigm for enhancing motor adaptation by amplifying movement errors rather than compensating for them. However, integrating EA into human-in-the-loop (HITL) control systems remains challenging. This difficulty arises from the lack of performance metrics that reflect neuromuscular adaptation and the limited ability to efficiently adapt control parameters to user-specific motor strategies. To address these challenges, we propose a HITL control framework that leverages muscle synergy analysis to guide the personalization of EA intensity. A synergy-based performance metric was designed to quantify motor adaptation by measuring structural similarity across muscle synergies. This metric served as the optimization objective for a Gaussian process-based Bayesian algorithm, which adaptively tuned the EA gain based on individual responses. An 8-day study involving ten healthy subjects performing non-dominant limb reaching tasks validated the proposed framework. The experimental group achieved significantly greater reductions in trajectory deviation than the control group, alongside robust within-group improvements (p < 0.01) and positive inter-group trends in muscle synergy similarities (gw,gc). These results demonstrate reliable convergence of the optimization process, robust inter-subject adaptability, and the effectiveness of the synergy metric in capturing adaptation. Overall, the findings highlight the potential of the proposed framework as a foundational tool for adaptive motor training in human–robot interaction systems.
- Top Cited Papers
- 1 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (2) , 579-590
Design, Modeling and Evaluation of Lattice Structure Pneumatic Actuators (LSPAs) for Soft Wrist Rehabilitation Robot
Soft robots have gained recognition as promising solutions in rehabilitation robotics due to their intrinsic flexibility and safety features. However, they often encounter challenges related to output efficiency and portability. This paper presents the design, modeling, and evaluation of an innovative wrist rehabilitation robot that employs two double-layer lattice structure pneumatic actuators (DLSPAs) to enhance efficiency. Key parameters of these DLSPAs are optimized through a mathematical model, with calibration experiments indicating that the discrepancy between actual and predicted values remains within 4% of the DLSPAs' maximum output force, thereby validating the model's accuracy. Furthermore, the DLSPAs achieve an end output force of 27.02 N, marking a 156% increase compared to single-layer lattice structure pneumatic actuators (SLSPAs) and underscoring the structural advantages of the design. To evaluate the clinical efficacy of the wrist rehabilitation robot, trials were conducted with 8 individuals post-stroke. Results demonstrate that, with robotic assistance, participants' lifting force reached 4.85 N and 5.11 N in dorsal extension and palmar flexion, respectively, with corresponding angular movements of 36.40° and 38.36°. These findings suggest that the lattice-structured soft wrist rehabilitation robot offers substantial potential for effective assisted rehabilitation training.
- 1 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (2) , 579-590
Top Cited PapersDesign, Modeling and Evaluation of Lattice Structure Pneumatic Actuators (LSPAs) for Soft Wrist Rehabilitation Robot
Soft robots have gained recognition as promising solutions in rehabilitation robotics due to their intrinsic flexibility and safety features. However, they often encounter challenges related to output efficiency and portability. This paper presents the design, modeling, and evaluation of an innovative wrist rehabilitation robot that employs two double-layer lattice structure pneumatic actuators (DLSPAs) to enhance efficiency. Key parameters of these DLSPAs are optimized through a mathematical model, with calibration experiments indicating that the discrepancy between actual and predicted values remains within 4% of the DLSPAs' maximum output force, thereby validating the model's accuracy. Furthermore, the DLSPAs achieve an end output force of 27.02 N, marking a 156% increase compared to single-layer lattice structure pneumatic actuators (SLSPAs) and underscoring the structural advantages of the design. To evaluate the clinical efficacy of the wrist rehabilitation robot, trials were conducted with 8 individuals post-stroke. Results demonstrate that, with robotic assistance, participants' lifting force reached 4.85 N and 5.11 N in dorsal extension and palmar flexion, respectively, with corresponding angular movements of 36.40° and 38.36°. These findings suggest that the lattice-structured soft wrist rehabilitation robot offers substantial potential for effective assisted rehabilitation training.
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (3) , 2817-2828
TACSEM: Tactile Sensing, 3-D State Estimation and In-Hand Manipulation of a Soft Hand
In this article, we present a pneumatic soft hand with integrated tactile sensing, state estimation, and embodied intelligence capabilities. A novel state estimation method is proposed based on the linear elasticity theory. Following the theoretical principles above, the hardware for the soft hand is developed, which includes the fabrication of soft fingers with multiple sensors and the design of controller circuits. The soft hand achieves real-time tactile sensing for all three fingers at 7 Hz. A multimodal state estimation neural network is proposed to learn the principles of state estimation. It estimates the 3-D finger state with a 1.73 mm average error in 4.21 ms when deployed on the soft hand controller with a Jetson Orin Nano.Embodied intelligence in the soft hand is realized through vision-language models using a hierarchical pyramid prompt architecture, enabling the hand to perform in-hand manipulations using only the movements of its soft fingers, achieving an average success rate of 92.5%. The prompts, 3-D models, PCB images, source code, and video demos are provided in the supplemental materials attached to this article.
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (3) , 2817-2828
TACSEM: Tactile Sensing, 3-D State Estimation and In-Hand Manipulation of a Soft Hand
In this article, we present a pneumatic soft hand with integrated tactile sensing, state estimation, and embodied intelligence capabilities. A novel state estimation method is proposed based on the linear elasticity theory. Following the theoretical principles above, the hardware for the soft hand is developed, which includes the fabrication of soft fingers with multiple sensors and the design of controller circuits. The soft hand achieves real-time tactile sensing for all three fingers at 7 Hz. A multimodal state estimation neural network is proposed to learn the principles of state estimation. It estimates the 3-D finger state with a 1.73 mm average error in 4.21 ms when deployed on the soft hand controller with a Jetson Orin Nano.Embodied intelligence in the soft hand is realized through vision-language models using a hierarchical pyramid prompt architecture, enabling the hand to perform in-hand manipulations using only the movements of its soft fingers, achieving an average success rate of 92.5%. The prompts, 3-D models, PCB images, source code, and video demos are provided in the supplemental materials attached to this article.
- Open Access
- 2 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 149-162
The Role of Vibrotactile Stimulation in Soft Rehabilitation Glove-Assisted Hand Rehabilitation Training: A Pilot Study
Brain-controlled robotic hand rehabilitation systems based on motor intention recognition have been used to promote recovery of hand function in stroke patients. However, the low decoding accuracy of motor imagery (MI) and unclear neural response mechanisms limit its widespread application. This study introduces a novel vibrotactile-assisted brain-controlled soft robotic hand rehabilitation system to validate its effectiveness in activating the motor sensory areas of the brain and to explore the neural response mechanisms of vibration stimulation in hand rehabilitation training. A total of 23 healthy subjects and 5 stroke patients were recruited to perform EEG and fNIRS-based experiments. Healthy subjects performed an EEG-based active rehabilitation task and an fNIRS-based passive rehabilitation task driven by the soft glove. Stroke patients only completed an EEG-based passive rehabilitation task. All experiments were conducted under two conditions: with and without vibrotactile stimulation. EEG results revealed that vibration stimulation significantly enhanced motor-sensory cortex activation during MI, and improved the online decoding performance of subjects with poor training outcomes. Grasping and stretching movements driven by the soft glove effectively activated the subjects’ motorsensory cortex. Vibration stimulation boosted the event-related desynchronization (ERD) phenomenon in the contralateral somatosensory cortex of the healthy subjects, but was not significant in the motor cortex. Meanwhile, it strengthened bilateral sensorimotor activation in stroke patients. Moreover, fNIRS results indicated that vibration stimulation increased the concentration of HbO in the motor-sensory areas during passive movement and enhanced the bidirectional functional connectivity between the left and right hemispheres. These findings suggest that the proposed tactile-assisted hand rehabilitation system can effectively enhance neural activation in the motor-sensory cortex, potentially leading to improved hand function recovery in stroke patients.
- 2 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 149-162
Open AccessThe Role of Vibrotactile Stimulation in Soft Rehabilitation Glove-Assisted Hand Rehabilitation Training: A Pilot Study
Brain-controlled robotic hand rehabilitation systems based on motor intention recognition have been used to promote recovery of hand function in stroke patients. However, the low decoding accuracy of motor imagery (MI) and unclear neural response mechanisms limit its widespread application. This study introduces a novel vibrotactile-assisted brain-controlled soft robotic hand rehabilitation system to validate its effectiveness in activating the motor sensory areas of the brain and to explore the neural response mechanisms of vibration stimulation in hand rehabilitation training. A total of 23 healthy subjects and 5 stroke patients were recruited to perform EEG and fNIRS-based experiments. Healthy subjects performed an EEG-based active rehabilitation task and an fNIRS-based passive rehabilitation task driven by the soft glove. Stroke patients only completed an EEG-based passive rehabilitation task. All experiments were conducted under two conditions: with and without vibrotactile stimulation. EEG results revealed that vibration stimulation significantly enhanced motor-sensory cortex activation during MI, and improved the online decoding performance of subjects with poor training outcomes. Grasping and stretching movements driven by the soft glove effectively activated the subjects’ motorsensory cortex. Vibration stimulation boosted the event-related desynchronization (ERD) phenomenon in the contralateral somatosensory cortex of the healthy subjects, but was not significant in the motor cortex. Meanwhile, it strengthened bilateral sensorimotor activation in stroke patients. Moreover, fNIRS results indicated that vibration stimulation increased the concentration of HbO in the motor-sensory areas during passive movement and enhanced the bidirectional functional connectivity between the left and right hemispheres. These findings suggest that the proposed tactile-assisted hand rehabilitation system can effectively enhance neural activation in the motor-sensory cortex, potentially leading to improved hand function recovery in stroke patients.
- 8 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Physical-Based Hysteresis Modeling and Compensation for Magnetorheological Actuator With Asymmetric and Rate-Dependent Behaviors
Magnetorheological actuator (MRA) offers advantages such as controllability, low consumption, and inherent safety. However, its practical application is hindered by asymmetric and rate-dependent hysteresis, which degrades torque estimation accuracy and control complexity. Existing hysteresis models often rely on universal frameworks or introduce additional dynamic elements to capture rate-dependent behavior, leading to increased parameter complexity and limited physical interpretability. To address these issues, this paper proposes a novel physics-based hysteresis model that integrates the mechanical and electromagnetic properties of MRA to characterize asymmetric and rate-dependent hysteresis. Unlike conventional models, the structure of the proposed model is derived directly from the actuator’s physical principles, enabling more accurate torque estimation with few parameters. Furthermore, a self-rate-dependent operator is introduced to describe rate-dependent hysteresis without the need for extra dynamic terms, resulting in a more compact and efficient model formulation. Theoretical analysis and simulations validate the structural characteristics of the proposed model. In addition, an inverse model is developed and incorporated into a torque compensation strategy, effectively improving torque tracking performance. Numerous experiments demonstrate the feasibility and effectiveness of the proposed model in both hysteresis compensation and torque control.
- 8 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Physical-Based Hysteresis Modeling and Compensation for Magnetorheological Actuator With Asymmetric and Rate-Dependent Behaviors
Magnetorheological actuator (MRA) offers advantages such as controllability, low consumption, and inherent safety. However, its practical application is hindered by asymmetric and rate-dependent hysteresis, which degrades torque estimation accuracy and control complexity. Existing hysteresis models often rely on universal frameworks or introduce additional dynamic elements to capture rate-dependent behavior, leading to increased parameter complexity and limited physical interpretability. To address these issues, this paper proposes a novel physics-based hysteresis model that integrates the mechanical and electromagnetic properties of MRA to characterize asymmetric and rate-dependent hysteresis. Unlike conventional models, the structure of the proposed model is derived directly from the actuator’s physical principles, enabling more accurate torque estimation with few parameters. Furthermore, a self-rate-dependent operator is introduced to describe rate-dependent hysteresis without the need for extra dynamic terms, resulting in a more compact and efficient model formulation. Theoretical analysis and simulations validate the structural characteristics of the proposed model. In addition, an inverse model is developed and incorporated into a torque compensation strategy, effectively improving torque tracking performance. Numerous experiments demonstrate the feasibility and effectiveness of the proposed model in both hysteresis compensation and torque control.
- Open Access
- 1 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 2988-2999
Control of Soft Wearable Robots for Elbow Assistance and Rehabilitation: A Simplified Solution Using Disturbance Observer and Nonsmooth Feedback
Soft wearable robots present a promising approach for elbow assistance and rehabilitation. However, most existing devices rely on open-loop control strategies, which renders individual customization cumbersome and incapable of adapting to dynamic interactions. The challenges in implementing closed-loop control arise from the complex nonlinearities of soft robots and the unpredictable external disturbances encountered during human-robot interactions. To achieve closed-loop control of elbow soft wearable robots, this paper proposes a disturbance observer (DO)-based nonsmooth feedback (NSF) method. Specifically, a tailored DO is designed to enhance feedforward compensation by analyzing the unique characteristics of the disturbances encountered in practical systems. A nonrecursive NSF is employed to suppress residual disturbances and nonlinearities, with the finite-time stability of the closed-loop system rigorously guaranteed. The proposed method balances efficacy and simplicity by leveraging the concise models of both the system and disturbances to enhance performance while avoiding intricate modeling. Moreover, its nonrecursive design results in a straightforward control law and facilitates implementation. Extensive comparison and ablation experiments validate the superiority of the proposed method over existing approaches. Human trials involving 8 healthy subjects and 7 stroke patients demonstrate that our method enhances task performance, reduces muscle strain during elbow assistance scenarios, and significantly improves elbow motor function in rehabilitation training.
- 1 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 2988-2999
Open AccessControl of Soft Wearable Robots for Elbow Assistance and Rehabilitation: A Simplified Solution Using Disturbance Observer and Nonsmooth Feedback
Soft wearable robots present a promising approach for elbow assistance and rehabilitation. However, most existing devices rely on open-loop control strategies, which renders individual customization cumbersome and incapable of adapting to dynamic interactions. The challenges in implementing closed-loop control arise from the complex nonlinearities of soft robots and the unpredictable external disturbances encountered during human-robot interactions. To achieve closed-loop control of elbow soft wearable robots, this paper proposes a disturbance observer (DO)-based nonsmooth feedback (NSF) method. Specifically, a tailored DO is designed to enhance feedforward compensation by analyzing the unique characteristics of the disturbances encountered in practical systems. A nonrecursive NSF is employed to suppress residual disturbances and nonlinearities, with the finite-time stability of the closed-loop system rigorously guaranteed. The proposed method balances efficacy and simplicity by leveraging the concise models of both the system and disturbances to enhance performance while avoiding intricate modeling. Moreover, its nonrecursive design results in a straightforward control law and facilitates implementation. Extensive comparison and ablation experiments validate the superiority of the proposed method over existing approaches. Human trials involving 8 healthy subjects and 7 stroke patients demonstrate that our method enhances task performance, reduces muscle strain during elbow assistance scenarios, and significantly improves elbow motor function in rehabilitation training.