STS. Teruel-Pardo

S. Teruel-Pardo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


S. Teruel-Pardo has a total of 153 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Demonstration of sub-percent energy resolution in the NEXT-100 detector

    by M. Pérez Maneiro, M. Martínez-Vara, S. Torelli, G. Martínez-Lema, P. Novella, J. A. Hernando Morata, J. J. Gómez-Cadenas, C. Adams, H. Almazán, V. Álvarez, et al.

    NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to $$\sim $$ ∼ 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ( $$\beta \beta 0\nu $$ β β 0 ν ) of $$ ^{136}\mathrm Xe$$ 136 X e . The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ( $$Q_{\beta \beta }$$ Q β β = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a $$ ^{228}\textrm{Th}$$ 228 Th source, demonstrating excellent linear response and an energy resolution of $$(0.90 \pm 0.02)\%$$ ( 0.90 ± 0.02 ) % FWHM at the $$^{208}$$ 208 Tl photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $$R(Q_{\beta \beta }) = (0.93 \pm 0.02)\%$$ R ( Q β β ) = ( 0.93 ± 0.02 ) % FWHM, confirming the detector’s capability for precision energy measurement in the search for $$\beta \beta 0\nu $$ β β 0 ν .

  • Open Access

    First results of the NEXT-100 detector using 83mKr decays

    by G. Martínez-Lema, C. Hervés Carrete, S. Torelli, M. Cid Laso, P. Vázquez Cabaleiro, B. Palmeiro, J. A. Hernando Morata, J. J. Gómez-Cadenas, C. Adams, H. Almazán, et al.

    The NEXT collaboration is investigating the double beta decay of $$ ^{136}\mathrm Xe$$ 136 X e using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $$^{83\text {m}}\textrm{Kr}$$ 83 m Kr decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $$^{83\text {m}}\textrm{Kr}$$ 83 m Kr point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $$E^{-1/2}$$ E - 1 / 2 extrapolation to $$Q_{\beta \beta }$$ Q β β yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.

  • Open Access

    Measurement of the scintillation resolution in liquid xenon and its impact for future segmented calorimeters

    by C. Romo-Luque, N. Salor-Iguiñiz, J. M. Benlloch-Rodríguez, R. Esteve, R. J. Aliaga, V. Álvarez, F. Ballester, R. Gadea, J. Generowicz, A. Laing, et al.

    We report on a measurement of the energy resolution that can be attained in liquid xenon when recording only the scintillation light. Our setup is optimized to maximize light collection and uses state-of-the-art, high-PDE (photodetection efficiency), VUV-sensitive silicon photomultipliers. We find a value of 3.7 % ± 0.4 % at 511 keV, once saturation effects are corrected for, a result close to the Poissonian resolution that we expect in our setup ( 2.8 % ± 0.4 % at 511 keV). Our results in the intrinsic resolution ( 2.3 % ± 0.8 % ) are compatible, within errors, at 511 keV, with those found by theoretical estimations that have been standing for the last 20 years, 1.8 % . Our work opens possibilities for apparatus based on liquid xenon and using scintillation only. In particular, it suggests that modular scintillation detectors using liquid xenon can be very competitive as building blocks in segmented calorimeters, with applications to Positron Emission Tomography technology.

  • Top Cited Papers
    Open Access

    The NEXT-100 Detector

    by C. Adams, H. Almazán, V. Álvarez, A. I. Aranburu, L. Arazi, I. J. Arnquist, F. Auria-Luna, S. Ayet, Y. Ayyad, C. D. R. Azevedo, et al.

    The NEXT collaboration is dedicated to the study of double beta decays of $$^{136}$$ 136 Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution ( $$\le 1\%$$ ≤ 1 % FWHM at the $$Q_{\beta \beta }$$ Q β β value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at $$\sim $$ ∼ 4 bar and drift fields of $$74\hbox { V cm}^{-1}$$ 74 V cm - 1 and $$118\hbox { V cm}^{-1}$$ 118 V cm - 1 , respectively. Alpha decays from the $$^{222}$$ 222 Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.


  • Open Access

    Evaluation of coincidence time resolution in a liquid xenon detector with silicon photomultipliers

    by N. Salor-Iguiñiz, J. M. Benlloch-Rodríguez, R. Esteve, V. Álvarez, F. Ballester, R. Gadea, J. Rodríguez, J. F. Toledo, R. Torres-Curado, V. Herrero, et al.

    This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first prototype optimized to maximize light collection using high photodetection efficiency (PDE), VUV-sensitive sensors and to minimize time fluctuations. We report a coincidence time resolution of 281 ± 2 ps FWHM, obtained using a Na 22 calibration source. This result is competitive with the current state-of-the-art PET scanners and represents a significant step forward in the development of liquid xenon as a viable alternative to conventional scintillators in PET technology.


  • Open Access

    Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging

    by M. Martínez-Vara, K. Mistry, F. Pompa, B. J. P. Jones, J. Martín-Albo, M. Sorel, C. Adams, H. Almazán, V. Álvarez, B. Aparicio, et al.

    A bstract: If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $$ \overline{\cos\ \theta } $$ cos θ ¯ and $$ \overline{T_1} $$ T 1 ¯ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.