STSamuele Torelli

Samuele Torelli

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Samuele Torelli has a total of 289 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    ITACA revisited: ion tracking apparatus with CMOS ASICs

    by J. J. Gómez-Cadenas, L. Arazi, G. Martínez-Lema, J. Renner, S. R. Soleti, S. Torelli

    High-pressure xenon gas TPCs with electroluminescent amplification provide detailed topological reconstruction of charged-particle trajectories, offering a distinctive two-electron signature for neutrinoless double beta decay ( $$\beta \beta 0\nu $$ β β 0 ν ) searches. We recently proposed ITACA, a detector concept that images both the electron track and the corresponding ion track. While electrons drift rapidly to the anode for standard EL imaging, the positive ions drift slowly to the cathode with millimetre-scale diffusion, allowing time to determine the event energy and barycenter and to position a movable ion detector at the projected arrival point of the ion cloud. We present a conceptual design of the ITACA detector, addressing key feasibility questions. First, we define the detector geometry and operating parameters for a 1-tonne-scale instrument at 15 bar, including a modular tiled electroluminescent structure. Second, we present the conceptual design of the Magnetically Actuated Rotor System (MARS), the mechanism that positions the ion sensor at any coordinate below the cathode, and show that the expected movement time is fast enough to retain $$\sim 93\%$$ ∼ 93 % of the drift volume for ion detection, while not significantly perturbing the gas on the scales of the ion drift. Third, we propose using a Topmetal CMOS ASIC-based ion detector, enabling real-time, 3D imaging of the ion track without the need for offline laser scanning. Finally, we estimate the sensitivity of the proposed apparatus, showing that enhanced topological discrimination from the ion track, combined with an ultra-low background design, allows exploration of $$\beta \beta 0\nu $$ β β 0 ν half-lives in excess of $$10^{28}$$ 10 28 yr.

  • Open Access

    Demonstration of sub-percent energy resolution in the NEXT-100 detector

    by M. Pérez Maneiro, M. Martínez-Vara, S. Torelli, G. Martínez-Lema, P. Novella, J. A. Hernando Morata, J. J. Gómez-Cadenas, C. Adams, H. Almazán, V. Álvarez, et al.

    NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to $$\sim $$ ∼ 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ( $$\beta \beta 0\nu $$ β β 0 ν ) of $$ ^{136}\mathrm Xe$$ 136 X e . The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ( $$Q_{\beta \beta }$$ Q β β = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a $$ ^{228}\textrm{Th}$$ 228 Th source, demonstrating excellent linear response and an energy resolution of $$(0.90 \pm 0.02)\%$$ ( 0.90 ± 0.02 ) % FWHM at the $$^{208}$$ 208 Tl photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $$R(Q_{\beta \beta }) = (0.93 \pm 0.02)\%$$ R ( Q β β ) = ( 0.93 ± 0.02 ) % FWHM, confirming the detector’s capability for precision energy measurement in the search for $$\beta \beta 0\nu $$ β β 0 ν .

  • Open Access

    Radon-induced backgrounds in the NEXT-100 experiment

    by C. Cortes-Parra, P. Novella, G. Martínez-Lema, H. Almazán, V. Álvarez, L. Arazi, I. J. Arnquist, F. Auria-Luna, S. Ayet, Y. Ayyad, et al.

    A bstract: The NEXT-100 detector at the LSC aims at the first competitive search for the 0 νββ decay using a high-pressure 136 Xe electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal 222 Rn activity is found to be (0.95 ± 0.04(stat) ± 0.09(sys)) Bq/m 3 , while no traces of 220 Rn have been observed. Most of the 222 Rn progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced 214 Bi of (0.97 ± 0.05(stat) ± 0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the 0 νββ region of interest is evaluated as (7.3 ± 1.5(stat) ± 0.8(sys)) × 10 − 4 counts/(keV · kg · yr) after selection of the fully contained events. This background index is reduced to ∼ 4 × 10 − 5 counts/(keV · kg · yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.

  • Open Access

    Characterization of field cage and cathode for low radioactivity operation with the CYGNO experiment

    by F.D. Amaro, R. Antonietti, E. Baracchini, L. Benussi, S. Bianco, A. Biondi, C. Capoccia, M. Caponero, L.G.M. de Carvalho, G. Cavoto, et al.

    Dark matter, which is considered to account for approximately the 27% of the Universe's energy-mass content, remains an open issue in modern particle physics along with its composition. The CYGNO Experiment aims to exploit an innovative approach applied to the direct detection search of low energy nuclear recoils possibly induced by cold particle-like dark matter candidates. CYGNO employs a directional detector based on a Time Projection Chamber (TPC) filled with a He:CF 4 gas mixture and equipped with an optical readout. Currently, the CYGNO Collaboration is constructing the detector demonstrator, CYGNO-04, in Hall F at Laboratori Nazionali del Gran Sasso (LNGS). This 0.4 m 3 detector has the goal of proving the scalability of the technology and assessing the physics and radiopurity capabilities. Given the low radioactivity requirements, especially in internal components such as field cage and cathode, the reduction of material while keeping the correct electrical behavior is paramount. In this paper, we present the validation of several internal components, mainly focusing on the field cage material and support structure. The tests included geometrical asymmetries in the electric field response, collection efficiency as well as measurement of known physical quantities. A preferred configuration is found with a structure based on Nylon material which supports a PET or Kapton sheet with copper strips deposited on.

  • Open Access

    First results of the NEXT-100 detector using 83mKr decays

    by G. Martínez-Lema, C. Hervés Carrete, S. Torelli, M. Cid Laso, P. Vázquez Cabaleiro, B. Palmeiro, J. A. Hernando Morata, J. J. Gómez-Cadenas, C. Adams, H. Almazán, et al.

    The NEXT collaboration is investigating the double beta decay of $$ ^{136}\mathrm Xe$$ 136 X e using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $$^{83\text {m}}\textrm{Kr}$$ 83 m Kr decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $$^{83\text {m}}\textrm{Kr}$$ 83 m Kr point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $$E^{-1/2}$$ E - 1 / 2 extrapolation to $$Q_{\beta \beta }$$ Q β β yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.

  • Open Access

    Simulation of the CYGNO gaseous TPC optical readout

    by F.D. Amaro, R. Antonietti, E. Baracchini, L. Benussi, S. Bianco, C. Capoccia, M. Caponero, L.G.M. de Carvalho, G. Cavoto, I.A. Costa, et al.

    Gaseous Time Projection Chambers with Optical Readout are sensitive detectors suitable for 3D measurement of low-energy particles (of order 1 keV) and are proposed for detecting rare events such as Dark Matter particle interactions. The CYGNO collaboration is developing such a detector with a high spatial and energy resolution, leveraging an innovative optical readout system. A reliable simulation of the detector response is needed to properly assess the physics reach of this technique and to better understand the performance of the detector in the development phase. Such a simulation cannot entirely rely on existing software packages; indeed, none of the available tools is capable of properly and reliably treating the different phenomena occurring in the detector, from the primary interaction in the gas volume throughout the whole detector response model, including charge transport, light production and propagation, and the response of the optical sensors. In this paper, we present a modeling of the detector response tuned on the CYGNO Optical TPC case; a description of the method is reported together with comparisons with experimental data from the LIME prototype to demonstrate the simulation performances.

  • Open Access

    The CYGNO experiment: a gaseous TPC with optical readout for rare events searches

    by F.D. Amaro, R. Antonietti, E. Baracchini, L. Benussi, C. Capoccia, M. Caponero, L.G.M. de Carvalho, G. Cavoto, I.A. Costa, A. Croce, et al.

    The CYGNO collaboration is developing a novel strategy for directional Dark Matter searches based on a gaseous Time Projection Chamber (TPC). The detector is optimized for the exploration of light (0.5–50 GeV) WIMPs-like particles and employs a He/CF 4 gas mixture at atmospheric pressure, sensitive to both spin-dependent and spin-independent interactions. A key feature of the project is its optical readout, which relies on photon detection rather than charge collection. In CYGNO detectors, electrons released by ionizing tracks drift toward an amplification stage of three Gas Electron Multipliers (GEMs). The electron avalanches generate scintillation light that is captured by scientific CMOS (sCMOS) cameras for high-resolution two-dimensional imaging and by Photomultiplier Tubes (PMTs) that provide a precise time profile along the drift direction. This allows a 3D event reconstruction, detailed energy deposition mapping, and effective topology and head-to-tail discrimination. Building on the achievements of the 50 L prototype (LIME), which successfully operated underground at LNGS, the next step is the deployment of a 0.4 m 3 demonstrator, CYGNO-04, to be completed in 2026. The demonstrator will validate scalability and confirm the advantages of the proposed technique. Recent results from LIME highlight strong progress in 3D tracking and particle identification. The current status of CYGNO-04 and its role in advancing the program will be presented as well.

  • Open Access

    A journey to ITACA

    by J. J. Gómez-Cadenas, L. Arazi, M. Elorza, Z. Freixa, F. Monrabal, A. Pazos, J. Renner, S. R. Soleti, S. Torelli

    A unique feature of gas xenon electroluminescent time projection chambers (GXeEL TPCs) in $$\beta \beta 0\nu $$ β β 0 ν searches is their ability to reconstruct event topology, in particular to distinguish “single-electron” from “double-electron” tracks, the latter being the signature of a $$\beta \beta 0\nu $$ β β 0 ν decay near the decay endpoint $$Q_{\beta \beta }$$ Q β β . Together with excellent energy resolution and the t $$_0$$ 0 provided by primary scintillation, this topological information is key to suppressing backgrounds. Preserving EL, however, requires operation in pure xenon (with helium as the only benign additive), where electron diffusion is large. Consequently, reconstructed track fidelity is limited by diffusion and intrinsic EL blurring. We propose augmenting the detector with the ability to image not only the electron track but also the corresponding mirror ion track. Introducing trace amounts of $$\mathrm{NH_3}$$ NH 3 ( $$\sim $$ ∼ 100 ppb) converts primary xenon ions into ammonium ions, $$\mathrm{NH_4^{+}}$$ NH 4 + , via a fast two-step ion–molecule process involving charge transfer followed by proton transfer, while leaving EL unaffected. Electrons drift rapidly to the anode, producing the standard EL image, whereas $$\mathrm{NH_4^{+}}$$ NH 4 + ions drift slowly toward the cathode, allowing time to determine the event energy and barycenter. For events in the region of interest, an ion sensor near the cathode at the projected barycenter captures the ions. Laser interrogation of the sensor’s molecular layer then reveals an ion-track image with sub-millimeter diffusion and no EL-induced smearing. Combined electron–ion imaging strengthens topological discrimination, improving background rejection by about an order of magnitude and significantly extending the discovery potential of GXeEL TPCs for very long $$\beta \beta 0\nu $$ β β 0 ν lifetimes.

  • Open Access

    Modeling the light response of an optically readout GEM based TPC for the CYGNO experiment

    by Fernando Domingues Amaro, Rita Antonietti, Elisabetta Baracchini, Luigi Benussi, Stefano Bianco, Roberto Campagnola, Cesidio Capoccia, Michele Caponero, Gianluca Cavoto, Igor Abritta Costa, et al.

    The use of gaseous Time Projection Chambers enables the detection and the detailed study of rare events due to particles interactions with the atoms of the gas with energy releases as low as a few keV. Due to this capability, these instruments are being developed for applications in the field of astroparticle physics, such as the study of dark matter and neutrinos. To acquire events occurring in the sensitive volume with a high granularity, the Cygno collaboration is developing a solution where the light generated during the avalanche processes occurring in a multiplication stage based on Gas Electron Multiplier (GEM) is read out by optical sensors with very high sensitivity and spatial resolution. To achieve a high light output, gas gain values of the order of $$10^5\text {-}10^6$$ 10 5 - 10 6 are needed. In this working condition, a dependence of the detector response on the spatial density of the charge collected in the GEM holes has been observed, indicating a gain-reduction effect likely caused by space-charge buildup within the multiplication channels. This paper presents data collected with a prototype featuring a sensitive volume of about two liters, together with a model developed by the collaboration to describe and predict the gain dependence on charge density. A comparison with experimental data shows that the model reproduces, with a percent-level precision, the gain behaviour over nearly one order of magnitude.


  • Top Cited Papers
    Open Access

    The NEXT-100 Detector

    by C. Adams, H. Almazán, V. Álvarez, A. I. Aranburu, L. Arazi, I. J. Arnquist, F. Auria-Luna, S. Ayet, Y. Ayyad, C. D. R. Azevedo, et al.

    The NEXT collaboration is dedicated to the study of double beta decays of $$^{136}$$ 136 Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution ( $$\le 1\%$$ ≤ 1 % FWHM at the $$Q_{\beta \beta }$$ Q β β value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at $$\sim $$ ∼ 4 bar and drift fields of $$74\hbox { V cm}^{-1}$$ 74 V cm - 1 and $$118\hbox { V cm}^{-1}$$ 118 V cm - 1 , respectively. Alpha decays from the $$^{222}$$ 222 Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.