JHJay Herrin

Jay Herrin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jay Herrin has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Systematic Review and Independent Benchmarking of Automated Nerve Morphometry Methods

    by Benton Chuter, Min Young Kim, Andrew B. Stiemke, Nikhil Dave, Zirui Zhou, Jay Herrin, Matthew Miller, William White, T.J. Hollingsworth, Monica M. Jablonski

    Objective: To systematically review automated nerve morphometry tools and independently benchmark their performance on independent optic nerve datasets. Design: Systematic review and comparative benchmarking study. Controls: Benchmarking was performed using paraphenylenediamine-stained mouse (n = 85) and rat (n = 44) optic nerve images with manually annotated axon counts as ground truth. Methods: Published studies describing automated or semi-automated neural tissue morphometry tools were identified through systematic searches of PubMed, Embase, and Scopus through January 2026 following PRISMA guidelines. Data extraction covered 70 fields across tool capabilities, imaging modality, species, automation level, and validation approach. Eighteen eligible tools (8 deep learning [DL], 10 classical computer vision [CV]) were benchmarked on both mouse and rat independent datasets. Main Outcome Measures: Performance was assessed by mean absolute percentage error (MAPE), Pearson correlation, and median predicted-to-ground-truth ratio. Tools were ranked per image and compared using Friedman tests with Nemenyi post-hoc analysis. Results: Seventy-one studies met inclusion criteria, spanning from 1999 to 2026. Deep learning methods represented 38% (27/71) of studies, increasing from 0% before 2017 to over 55% of publications after 2020. Axon counting was the most common output (73%, 52/71), while only 35% (25/71) reported g-ratio. Among benchmarked tools, Marina (CV, 2010) achieved the lowest average MAPE (32.9%). The top five tools (MAPE ranging from 32.9 to 44.8%) included both CV and DL methods and were statistically indistinguishable by Friedman-Nemenyi analysis (p > 0.05). Performance varied substantially across datasets: AxonJ (CV) achieved the second best MAPE on rat images (27.7%) but the worst on mouse images (438.6%). Conclusions: No single tool demonstrated consistently superior performance across both datasets. Classical and deep learning approaches achieved comparable accuracy for axon counting. Tool selection should be guided by target species, tissue preparation protocol, and desired morphometric outputs. This systematic review and independent benchmarking study provide an evidence base for tool selection in optic nerve research.

  • Open Access

    Comparison of Deep Learning Tools for Optic Nerve Axon Quantification Finds Limited Generalizability on Independent Validation

    by Benton Chuter, Noah Emmert, Min Young Kim, Nikhil Dave, Jay Herrin, Zirui Zhou, Gideon Wall, Abraham Palmer, Hao Chen, T.J. Hollingsworth, et al.

    Purpose: Machine learning approaches for automated quantification of optic nerve histology have emerged as potential tools for objective assessment of axonal injury in experimental glaucoma models. However, the generalizability of these models to independent datasets remains unclear. Guided by a scoping review of the literature, this study performed independent validation testing of publicly available models on a novel rat optic nerve dataset to assess their generalizability. Methods: We conducted a scoping review following PRISMA-ScR guidelines. PubMed, EMBASE, Scopus, and Cochrane CENTRAL were searched from 2000 through 2025. Two reviewers independently screened records and extracted data on model characteristics and performance metrics. Additionally, we performed independent validation of three models (AxoNet, AxonDeepSeg, AxoNet 2.0) on a novel rat optic nerve dataset comprising 57 images with 9,514 manually annotated axons. Because AxonDeep is not publicly available, we instead evaluated AxonDeepSeg, a separate publicly available deep learning-based tool that, while not previously applied to optic nerve tissue, is widely used for nerve fiber segmentation. Results: From 2,036 records, four manuscripts describing three deep learning models met inclusion criteria. Published correlation coefficients between model predictions and reference counts ranged from 0.959 to 0.99. On independent validation, performance was reduced: AxoNet 2.0 achieved the highest correlation (r = 0.89), followed by AxonDeepSeg (r = 0.86) and AxoNet (r = 0.79). Segmentation quality metrics revealed high precision (>0.94) but low recall (0.18 to 0.27), with Dice coefficients of 0.29 to 0.40, substantially below published benchmarks of 0.81. Conclusions: Deep learning models for optic nerve histology demonstrate strong within-study performance but show meaningful performance decrements when applied to independent datasets. The observed generalizability gap (correlations 0.07 to 0.182 points below published values) demonstrates the need for standardized validation datasets and multi-center testing before widespread adoption of these tools.

  • Increasing Tube Thoracostomy Output Threshold to Less Than 300 mL Per Day is Not Associated With Increased Complications after Removal in Trauma Patients

    by Lee C. Givens, Chase A. Jordan, James W. Herrin, Yann-Leei L. Lee, Steven G. Miller, Thomas Capasso, Maryann Mbaka, Christopher M. Kinnard, Andrew C. Bright, Ashley Y. Williams, et al.

    Background: Tube thoracostomy (TT) is a life-saving intervention that has a high complication rate. While many institutions continue drainage until <200 mL/day, there is little data on removal with higher output. This study aimed to determine whether TT removal with higher output on the day of removal is associated with complication of tube thoracostomy (CTT). Materials and Methods: This was a retrospective study of patients who underwent TT due to traumatic hemothorax/pneumothorax. Data on demographics, admission vital signs, injury details, treatment course, and output on day of removal was collected. Output was classified as HIGH (200–299 mL at removal) or LOW (<200 mL). The primary outcome variable was development of CTT, which was defined as re-accumulation of HTX/PTX, development of an empyema, subsequent TT, or need for thoracic surgery following tube removal. Results: After applying exclusion criteria, we identified 315 patients for analysis. The average age was 41 years old, and 74% (233) were male. The mean duration of treatment with TT was 5 days. The mean output on the day of removal was 80 mL, with 10% having a volume between 200–299 mL on day of removal. Overall, 16% developed CTT. There was no difference in the rate of CTT after removal between HIGH and LOW groups. Multiple variable logistic regression showed only chest AIS was statistically significantly associated with CTT. Discussion: Complications after tube thoracostomy are common (16%), but patients with higher output were not more likely to develop a complication. Chest tubes can be safely removed with an output <300 mL/day.

  • Permitless Carry Laws and FIREARM-RELATED Injuries at a Level I Trauma Center

    by Jay Herrin, Lee Givens, Chase Jordan, Maryann Mbaka, Yannlei L. Lee, Steven Miller, Thomas Capasso, Christopher Kinnard, Andrew Bright, Ashley Y. Williams, et al.

    Firearm-related injuries (FRI) are a public health issue in the United States. Permitless carry laws (PCL) eliminate the need for permits to carry firearms. This study evaluates the effects of Alabama’s PCL implementation on FRI rates at a Level I trauma center. A retrospective study was conducted of patients treated for FRI between 2019 and 2023 at a Level 1 trauma center. Demographic data and clinical metrics were collected and analyzed, and FRI rates were calculated. FRI rates post-PCL were compared to pre-PCL. Over five years, 14 226 patients were evaluated, with 1630 sustaining FRI. The overall FRI rate was 11.5 per 100 trauma assessments, with a peak in 2021 (12.5) and a low in 2023 (10.3). Comparing pre- and post-PCL periods, the FRI rate decreased from 11.8 to 10.3 ( P = .019). This finding suggests that PCL did not result in an increase in firearm-related injuries at our institution. More robust studies are needed to comprehensively assess the impact of PCL on FRI.