CSChristopher Chandler Shallal

Christopher Chandler Shallal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Christopher Chandler Shallal has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A wireless magnetic implant system for continuous neuromuscular sensing

    by Christopher C. Shallal, Cameron R. Taylor, Seong Ho Yeon, Richard J. Casler, Dara Oseyemi, Guillermo Herrera-Arcos, Junqing Qiao, Tony Shu, Jay Xu, Daniel Levine, et al.


  • Open Access

    Continuous neural control of a 2-DOF ankle-foot prosthesis enables dynamic obstacle maneuvers after transtibial amputation

    by Tsung-Han Hsieh, Hyungeun Song, Christopher Shallal, Daniel V. Levine, Seong Ho Yeon, Junqing Qiao, Tony Shu, Matthew J. Carty, John McCullough, Hugh M. Herr

    Bionic reconstruction techniques that employ surgical neuroprosthetic interfaces, biomimetic control systems, and powered mechatronics have enabled versatile and biomimetic legged gait without reliance on intrinsic gait controllers. However, relative emphasis has been placed on the emulation of sagittal plane biomechanics while neglecting to provide control over frontal plane mechanics critical for terrain adaptation. Here, we present a 2-degree-of-freedom (DOF) bionic reconstruction at the transtibial amputation level that enables continuous neural control of both sagittal and frontal ankle and subtalar joint mechanics. To demonstrate its capabilities in a case study design, we integrated a 2-DOF robotic ankle-foot device via surface electromyographic electrodes to an individual provisioned with a surgical neuroprosthetic interface that augments residual muscle afferents. The subject was able to neurally control both degrees of freedom to regain nominal gait mechanics during both level-ground walking and continuous cross-slope navigation. Furthermore, the subject strategically traversed an obstacle course by dynamically hopping between a series of discrete cross-slope blocks, adapting to the slopes, and responding to rapid foot slips. These preliminary findings suggest that bionic reconstruction techniques can restore continuous neural control over multi-DOF prostheses to achieve agile locomotion over complex terrain. One-Sentence Summary A multi-DOF ankle-foot prosthesis under continuous neural control enables agile locomotion over complex terrain.

  • Open Access

    A wireless magnetic implant system for continuous neuromuscular sensing

    by Christopher Chandler Shallal, Cameron Roy Taylor, Seong Ho Yeon, Richard J. Casler, Dara Oseyemi, Guillermo Herrera-Arcos, Junqing Qiao, Tony Shu, Jay Xu, Daniel Levine, et al.

    Precise measurement of neuromuscular mechanics yields an intuitive control signal for producing synchronous movement with wearable robotics. Practically obtaining such measurements remains challenging as current muscle-sensing technologies excessively compromise between signal fidelity, system complexity, and invasiveness. Here we present a skin-mounted, magnetometer array platform that wirelessly tracks passive 3 mm diameter magnetic beads implanted within human muscle tissue for continuous neuromuscular sensing. The system employs customized high-density sensing electronics with an information-theoretic architecture to achieve sub-millimeter resolution of real-time muscle dynamics at tracking depths of up to 6 cm within the body. We deploy the platform in a first-in-human clinical study to track a constellation of permanently implanted magnets to enable multiple degree-of-freedom neuroprosthetic control. We demonstrate that the wireless muscle state estimation can outperform standard surface and implanted electromyography interfaces to achieve more accurate and responsive neuroprosthetic movement. Further, we successfully supplant electromyography altogether by extending the platform to detect muscle activation through magnetic induction alone. One-Sentence Summary: A skin-mounted magnetometer sensing array can wirelessly track 3 mm diameter permanent magnetic implants in humans to provide precise neuromuscular information for improved neuroprosthetic control compared to electromyography.

  • Tissue-integrated bionic knee restores versatile legged movement after amputation

    by Tony Shu, Daniel Levine, Seong Ho Yeon, Ethan Chun, Christopher C. Shallal, John McCullough, Rickard Brånemark, Matthew J. Carty, Marco Ferrone, Sean Boerhout, et al.

    Lower-extremity prostheses have evolved through mechanical redesigns that prioritize improved cyclic locomotion. However, this limited approach to limb restoration has precluded necessary progress toward recovering the versatile acyclic movements that constitute the remainder of human athleticism. We present an osseointegrated mechanoneural prosthesis that incorporates modified hard and soft tissues along with permanently implanted hardware in a neuroembodied design. We developed a biomimetic coupling between neuromuscular signaling and joint movement that exceeds the versatility of established control methods, which depend upon conventional amputation musculature and surface electromyography. Our findings also reveal that superior residual neuromuscular function can enable prosthetic movement speeds surpassing that of intact physiology. Anatomical prosthetic integration may be necessary for meeting, and possibly exceeding, the movement capabilities of an intact limb.