Valentina Roquemen-Echeverri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Valentina Roquemen-Echeverri has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Clara Mosquera-Lopez
Artificial Intelligence for Medical Systems (AIMS) Lab, Department of Biomedical Engineering, Oregon Health and Science University, Portland, USA
4 shared publications - Peter G. Jacobs
Oregon Health and Science University, Portland, OR, USA
3 shared publications Peter M. Schulman
Department of Anesthesiology and Perioperative Medicine, Oregon Health & Science University, Portland, OR, USA
3 shared publicationsBethany Wilson
Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
2 shared publicationsClara Mosquera-Lopez
Artificial Intelligence for Medical Systems (AIMS) Lab, Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
2 shared publicationsDaniel Scott
Tellunostics LLC, OR, USA
2 shared publications
Latest Publications
- 22 August 2026
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 46 (3) , 619-635
Physiology-guided artificial intelligence digital twins for simulating glucose dynamics in type 2 diabetes
- 22 August 2026
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 46 (3) , 619-635
Physiology-guided artificial intelligence digital twins for simulating glucose dynamics in type 2 diabetes
- 2 April 2026
- Published by Springer Nature in Neural Computing and Applications
- Vol. 38 (7) , 241
A physiologically-constrained neural network digital twin framework for replicating glucose dynamics in type 1 diabetes
- 2 April 2026
- Published by Springer Nature in Neural Computing and Applications
- Vol. 38 (7) , 241
A physiologically-constrained neural network digital twin framework for replicating glucose dynamics in type 1 diabetes
- 9 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3065-3074
An AI-Powered Tool for Automatic Heart Sound Quality Assessment and Segmentation
Objective: To design an AI-powered tool to automatically assess the quality of phonocardiogram (PCG) recordings, and then identify S1 and S2 heart sounds using PCG recordings only. Methods We used PCG recordings from two datasets; a publicly available dataset (the 2016 PhysioNet/CinC Challenge), and a dataset that we collected as part of a clinical study we are conducting at Oregon Health & Science University (OHSU). We developed a logistic regression classifier to score PCG signal quality using semi-supervised learning and a two-layer perceptron artificial neural network classifier with con textual time-and frequency-domain input features to detect fundamental S1 and S2 heart sounds. We also analyzed the impact of input features on the accuracy of S1 and S2 segmentation. Results: Our segmentation method detects fundamental S1 and S2 heart sounds with a precision of 93% and distinguishes S1/S2 heart sounds with area under the curve (AUC) of 97.1%. Conclusions: Implementing a signal quality assessment tool allows for better segmentation performance as only suitable signals are processed by the S1/S2 sound detection and classification algorithms. Distance between sounds in time-domain are able to distinguish between S1 and S2 with accuracy of 87.4%; however, by adding the frequency-domain features, the accuracy significantly improved to 9 2.4%. Significance: S1 an d S2 heart sound segmentation is the first step in the processes of detecting and classifying heart abnormalities from a PCG. Our proposed method is simple and effective for segmentation for this task. Consequently, it can facilitate the performance of subsequent tasks including the detection of heart murmurs.
- 9 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3065-3074
An AI-Powered Tool for Automatic Heart Sound Quality Assessment and Segmentation
Objective: To design an AI-powered tool to automatically assess the quality of phonocardiogram (PCG) recordings, and then identify S1 and S2 heart sounds using PCG recordings only. Methods We used PCG recordings from two datasets; a publicly available dataset (the 2016 PhysioNet/CinC Challenge), and a dataset that we collected as part of a clinical study we are conducting at Oregon Health & Science University (OHSU). We developed a logistic regression classifier to score PCG signal quality using semi-supervised learning and a two-layer perceptron artificial neural network classifier with con textual time-and frequency-domain input features to detect fundamental S1 and S2 heart sounds. We also analyzed the impact of input features on the accuracy of S1 and S2 segmentation. Results: Our segmentation method detects fundamental S1 and S2 heart sounds with a precision of 93% and distinguishes S1/S2 heart sounds with area under the curve (AUC) of 97.1%. Conclusions: Implementing a signal quality assessment tool allows for better segmentation performance as only suitable signals are processed by the S1/S2 sound detection and classification algorithms. Distance between sounds in time-domain are able to distinguish between S1 and S2 with accuracy of 87.4%; however, by adding the frequency-domain features, the accuracy significantly improved to 9 2.4%. Significance: S1 an d S2 heart sound segmentation is the first step in the processes of detecting and classifying heart abnormalities from a PCG. Our proposed method is simple and effective for segmentation for this task. Consequently, it can facilitate the performance of subsequent tasks including the detection of heart murmurs.