Xiaojuan Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiaojuan Zhang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Bo Jing
College of Aeronautical Engineering, Air Force Engineering University, Xi'an, China
1 shared publication- Bo Jing
Aeronautics Engineering College, Air Force Engineering University, Xi’an 710038, China
1 shared publication Jie Zhang
College of Mechanical Engineering, Xijing University, Xi'an, China
1 shared publication- Ruixu Yao
College of Artificial Intelligence, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication Xiangzhen Meng
College of Aeronautical Engineering, Air Force Engineering University, Xi'an, China
1 shared publication- Xiaoxuan Jiao
Aeronautics Engineering College, Air Force Engineering University, Xi’an 710038, China
1 shared publication
Latest Publications
- Open Access
- 8 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 29034
Impedance shaping based stabilization control method for DC Micro-grid Feed-forward compensation
The ports of the bi-directional converter exhibit negative impedance characteristics when the energy storage unit of a DC microgrid is operating in charging mode. This can decrease the system’s stability margin, potentially leading to oscillation instability. To address this issue, we propose a feed-forward compensation control method based on impedance shaping. This involves designing a transfer function within the current feed-forward loop of the energy storage converter to ensure that the current reference value follows changes in the bus voltage. Selecting an appropriate time constant ensures that the port impedance of the energy storage unit exhibits a positive resistive characteristic close to the oscillation frequency while retaining a negative impedance characteristic in the low-frequency range. This ensures the stability of system operation. MATLAB/Simulink simulations and RT-LAB semi-physical platform testing have verified that the proposed control method effectively enhances the system’s stability margin, ensuring stable operation and minimal steady-state voltage deviation.
- 8 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 29034
Open AccessImpedance shaping based stabilization control method for DC Micro-grid Feed-forward compensation
The ports of the bi-directional converter exhibit negative impedance characteristics when the energy storage unit of a DC microgrid is operating in charging mode. This can decrease the system’s stability margin, potentially leading to oscillation instability. To address this issue, we propose a feed-forward compensation control method based on impedance shaping. This involves designing a transfer function within the current feed-forward loop of the energy storage converter to ensure that the current reference value follows changes in the bus voltage. Selecting an appropriate time constant ensures that the port impedance of the energy storage unit exhibits a positive resistive characteristic close to the oscillation frequency while retaining a negative impedance characteristic in the low-frequency range. This ensures the stability of system operation. MATLAB/Simulink simulations and RT-LAB semi-physical platform testing have verified that the proposed control method effectively enhances the system’s stability margin, ensuring stable operation and minimal steady-state voltage deviation.
- Open Access
Advanced Multi-Scale CNN-BiLSTM for Robust Photovoltaic Fault Detection
The increasing deployment of photovoltaic (PV) systems necessitates robust fault detection mechanisms to ensure operational reliability and safety. Conventional approaches, however, struggle in complex industrial environments characterized by high noise, data incompleteness, and class imbalance. This study proposes an innovative Advanced CNN-BiLSTM architecture integrating multi-scale feature extraction with hierarchical attention to enhance PV fault detection. The proposed framework employs four parallel CNN branches with kernel sizes of 3, 7, 15, and 31 to capture temporal patterns across various time scales. These features are then integrated by an adaptive feature fusion network that utilizes multi-head attention. A two-layer bidirectional LSTM with temporal attention mechanism processes the fused features for final classification. Comprehensive evaluation on the GPVS-Faults dataset using a progressive difficulty validation framework demonstrates exceptional performance improvements. Under extreme industrial conditions, the proposed method achieves 83.25% accuracy, representing a substantial 119.48% relative improvement over baseline CNN-BiLSTM (37.93%). Ablation studies reveal that the multi-scale CNN contributes 28.0% of the total performance improvement, while adaptive feature fusion accounts for 22.0%. Furthermore, the proposed method demonstrates superior robustness under severe noise (σ = 0.20), high levels of missing data (15%), and significant outlier contamination (8%). These characteristics make the architecture highly suitable for real-world industrial deployment and establish a new paradigm for temporal feature fusion in renewable energy fault detection.
Open AccessAdvanced Multi-Scale CNN-BiLSTM for Robust Photovoltaic Fault Detection
The increasing deployment of photovoltaic (PV) systems necessitates robust fault detection mechanisms to ensure operational reliability and safety. Conventional approaches, however, struggle in complex industrial environments characterized by high noise, data incompleteness, and class imbalance. This study proposes an innovative Advanced CNN-BiLSTM architecture integrating multi-scale feature extraction with hierarchical attention to enhance PV fault detection. The proposed framework employs four parallel CNN branches with kernel sizes of 3, 7, 15, and 31 to capture temporal patterns across various time scales. These features are then integrated by an adaptive feature fusion network that utilizes multi-head attention. A two-layer bidirectional LSTM with temporal attention mechanism processes the fused features for final classification. Comprehensive evaluation on the GPVS-Faults dataset using a progressive difficulty validation framework demonstrates exceptional performance improvements. Under extreme industrial conditions, the proposed method achieves 83.25% accuracy, representing a substantial 119.48% relative improvement over baseline CNN-BiLSTM (37.93%). Ablation studies reveal that the multi-scale CNN contributes 28.0% of the total performance improvement, while adaptive feature fusion accounts for 22.0%. Furthermore, the proposed method demonstrates superior robustness under severe noise (σ = 0.20), high levels of missing data (15%), and significant outlier contamination (8%). These characteristics make the architecture highly suitable for real-world industrial deployment and establish a new paradigm for temporal feature fusion in renewable energy fault detection.