Jiao Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jiao Chen has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Chao-Feng Zeng
Hunan Provincial Key Laboratory of Geotechnical Engineering for Stability Control and Health Monitoring, School of Civil Engineering, Hunan University of Science and Technology, Xiangtan 411201, China
2 shared publications - Gang Zheng
Department of Civil Engineering, Tianjin University, Tianjin 300072, China
1 shared publication - Hongbo Chen
Department of Civil Engineering, Tongji University, Shanghai 200092, China
1 shared publication - Lei Lv
Hunan Provincial Key Laboratory of Geotechnical Engineering for Stability Control and Health Monitoring, School of Civil Engineering, Hunan University of Science and Technology, Xiangtan 411201, China
1 shared publication - Qi Tang
Hunan Provincial Key Laboratory of Geotechnical Engineering for Stability Control and Health Monitoring, School of Civil Engineering, Hunan University of Science and Technology, Xiangtan 411201, China
1 shared publication - Shuo Wang
Department of Civil Engineering, Tongji University, Shanghai 200000, China
1 shared publication
Latest Publications
- Open Access
Predicting the Hydraulic Head Difference Across a Metro Station During Excavation Dewatering
Excavation dewatering in densely urbanized areas inevitably disturbs surrounding groundwater systems and may generate hydraulic head differences across adjacent underground structures. Existing three-dimensional groundwater models can explicitly simulate such interactions; however, simplified quantitative relationships for rapidly estimating the head difference across an adjacent metro station under varying hydrogeological and geometric conditions remain limited. Based on a deep excavation project in Tianjin, this study develops and validates a three-dimensional groundwater model using Visual MODFLOW 2011.1 and investigates the hydraulic head difference across an adjacent metro station. The framework first establishes a baseline relationship using the curtain insertion ratio as the reference variable, and then introduces correction factors to account for the influences of four additional parameters—aquifer anisotropy, aquifer thickness, station depth, and pit-to-station distance. The resulting equation was compared with Visual MODFLOW results for selected scenarios at the Tianjin site. These comparisons support its use as a preliminary engineering approximation for estimating the hydraulic head difference across an adjacent metro station under similar dewatering and hydrogeological conditions.
Open AccessPredicting the Hydraulic Head Difference Across a Metro Station During Excavation Dewatering
Excavation dewatering in densely urbanized areas inevitably disturbs surrounding groundwater systems and may generate hydraulic head differences across adjacent underground structures. Existing three-dimensional groundwater models can explicitly simulate such interactions; however, simplified quantitative relationships for rapidly estimating the head difference across an adjacent metro station under varying hydrogeological and geometric conditions remain limited. Based on a deep excavation project in Tianjin, this study develops and validates a three-dimensional groundwater model using Visual MODFLOW 2011.1 and investigates the hydraulic head difference across an adjacent metro station. The framework first establishes a baseline relationship using the curtain insertion ratio as the reference variable, and then introduces correction factors to account for the influences of four additional parameters—aquifer anisotropy, aquifer thickness, station depth, and pit-to-station distance. The resulting equation was compared with Visual MODFLOW results for selected scenarios at the Tianjin site. These comparisons support its use as a preliminary engineering approximation for estimating the hydraulic head difference across an adjacent metro station under similar dewatering and hydrogeological conditions.
- Open Access
ABAQUS-Based Numerical Analysis of Land Subsidence Induced by Pit Pumping in Multi-Aquifer Systems
Foundation pit pumping induces groundwater drawdown both inside and outside the pit, consequently causing surrounding land subsidence. Based on actual engineering cases, this study established a three-dimensional numerical model using ABAQUS software (version 6.14-4) to systematically investigate the temporal evolution of groundwater drawdown and land subsidence during pit pumping, while quantifying the relationship between drawdown and subsidence stabilization time under different parameters. The key findings are as follows: (1) land subsidence stabilization time (50 days) is governed by external phreatic layer response, reaching 2.3 times longer than isolated aquifer conditions (22 days); (2) medium-permeability strata (0.01–10 K0,AdII) showed peak sensitivity to drawdown–subsidence coupling; (3) pumping from a confined aquifer extends the subsidence stabilization time by a factor of 1.1 compared to phreatic aquifer conditions. These findings provide valuable insights for the design and risk assessment of dewatering strategies in foundation pits within multi-aquifer systems.
Open AccessABAQUS-Based Numerical Analysis of Land Subsidence Induced by Pit Pumping in Multi-Aquifer Systems
Foundation pit pumping induces groundwater drawdown both inside and outside the pit, consequently causing surrounding land subsidence. Based on actual engineering cases, this study established a three-dimensional numerical model using ABAQUS software (version 6.14-4) to systematically investigate the temporal evolution of groundwater drawdown and land subsidence during pit pumping, while quantifying the relationship between drawdown and subsidence stabilization time under different parameters. The key findings are as follows: (1) land subsidence stabilization time (50 days) is governed by external phreatic layer response, reaching 2.3 times longer than isolated aquifer conditions (22 days); (2) medium-permeability strata (0.01–10 K0,AdII) showed peak sensitivity to drawdown–subsidence coupling; (3) pumping from a confined aquifer extends the subsidence stabilization time by a factor of 1.1 compared to phreatic aquifer conditions. These findings provide valuable insights for the design and risk assessment of dewatering strategies in foundation pits within multi-aquifer systems.