Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Huy Dinh has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Proof of Concept and Validation of Single-Camera AI-Assisted Live Thumb Motion Capture

    by Huy G. Dinh, Joanne Y. Zhou, Adam Benmira, Deborah E. Kenney, Amy L. Ladd

    Motion analysis can be useful for multiplanar analysis of hand kinematics. The carpometacarpal (CMC) joint has been traditionally difficult to capture with surface-based motion analysis but is the most commonly arthritic joint of the hand and is of particular clinical interest. Traditional 3D motion capture of the CMC joint using multiple cameras and reflective markers and manual goniometer measurement has been challenging to integrate into clinical workflow. We therefore propose a markerless single-camera artificial intelligence (AI)-assisted motion capture method to provide real-time estimation of clinically relevant parameters. Our study enrolled five healthy subjects, two male and three female. Fourteen clinical parameters were extracted from thumb interphalangeal (IP), metacarpal phalangeal (MP), and CMC joint motions using manual goniometry and live motion capture with the Google AI MediaPipe Hands landmarker model. Motion capture measurements were assessed for accuracy, precision, and correlation with manual goniometry. Motion capture demonstrated sufficient accuracy in 11 and precision in all 14 parameters, with mean error of −2.13 ± 2.81° (95% confidence interval [CI]: −5.31, 1.05). Strong agreement was observed between both modalities across all subjects, with a combined Pearson correlation coefficient of 0.97 (p < 0.001) and an intraclass correlation coefficient of 0.97 (p < 0.001). The results suggest AI-assisted live motion capture can be an accurate and practical thumb assessment tool, particularly in virtual patient encounters, for enhanced range of motion (ROM) analysis.


  • Abstract WP159: Examining The Utility Of 2D DSA For Carotid Stenosis Hemodynamic Pressure Analysis

    by Huy Dinh, Viktor Szeder, Fernando Vinuela, Aichi Chien

    Introduction: Measurement of local hemodynamic behavior is useful for assessing the pathology of carotid stenosis. In this study, we explore a novel method using two-dimensional digital subtraction angiography (2D DSA) to provide time-dependent pressure data. We performed comparative validation with computational fluid dynamics (CFD) and flow guidewire measurements as reference methods. Methods: A silicone phantom model of a carotid stenosis was prepared, filled with physiological saline, and connected to a flow pump (Vascular Simulations, LLC Left Heart Replicator) applying pulsatile flow. The stenosis model narrowed from a diameter of 1.37 cm to 0.58 cm for a length of 0.64 cm (NASCET=40%). Iodinated contrast media was injected, and time dependent pressure profiles at four regions of interest: 2 cm proximal to the stenosis, proximal end of the stenosis, distal end of the stenosis and 2 cm distal to the stenosis were derived from contrast intensity (I) obtained from 2D DSA background-subtracted intensity plots using previously published PVEC software. A Volcano flow guidewire sensor was utilized at the same four locations to collect flow data. Pulsatile CFD flow analysis was performed to extract flow data. Results: DSA PVEC contrast analysis allowed observation of distinct flow pulsatility. At 30fps, strong agreement of DSA contrast waveform matching CFD and guidewire flow measurements was found at the distal end of the stenosis over a period of linear contrast increase (constant dI/dt). Bland-Altman analysis was used to compare derived pressure with the reference methods over 3.5 cardiac cycles, from 5.9 s to 8.7 s after the initial injection of contrast. 2D DSA-derived pressure showed a mean departure of -10.24% (std. dev 14.65%) pressure obtained from CFD analysis, and a mean departure of -15.32% (std. dev 14.24%) from guidewire measurements for the duration. Conclusion: A novel computational approach suggests 2D DSA can provide real-time results to approximate carotid flow from 2D DSA. We showed using this novel approach the flow data is comparable with guide wire and CFD methods. Future experiments may allow it to provide a supplementary, non-invasive means to examine local hemodynamic behavior that is relevant to the evaluation of carotid stenosis.

  • Open Access

    Image‐Derived Metrics Quantifying Hemodynamic Instability Predicted Growth of Unruptured Intracranial Aneurysms

    by Hong‐Ho Yang, James Sayre, Huy Dinh, Kambiz Nael, Geoffrey Colby, Anthony Wang, Pablo Villablanca, Noriko Salamon, Aichi Chien

    Background: Although image‐derived predictors of intracranial aneurysm (IA) rupture have been well explored, current understanding of IA growth is limited. Pulsatility index (PI) and wall shear stress PI (WSSPI) are important metrics measuring temporal hemodynamic instability. However, they have not been investigated in IA growth research. The present study seeks to verify reliable predictors of IA growth with comparative analyses of several important morphological and hemodynamic metrics between stable and growing cases among a group of unruptured IAs. Methods: Using 3‐dimensional images, vascular models of 16 stable and 20 growing cases were constructed and verified using geodesic techniques. With an overall mean follow‐up period of 25 months, cases exhibiting a ≥10% increase in diameter were considered growing. Patient‐specific, pulsatile simulations were performed, and hemodynamic calculations were computed at 5 important regions of each aneurysm (inflow artery, aneurysm neck, body, dome, and outflow artery). Index values were compared between growing and stable IAs using ANCOVA controlling for aneurysm diameter. Stepwise multiple logistic regression and receiver operation characteristic analyses were conducted to investigate predictive models of IA growth. Results: Compared with stable IAs, growing IAs exhibited significantly higher intrasaccular PI, intrasaccular WSSPI, intrasaccular spatial flow rate deviation, and intrasaccular spatial wall shear stress deviation. Stepwise logistic regression analysis revealed a significant predictive model involving PI at aneurysm body, WSSPI at inflow artery, and WSSPI at aneurysm body. Conclusions: Our results showed that high degrees of hemodynamic variation within IAs are linked to growth, even after controlling for morphological parameters. Furthermore, evaluation of PI in conjunction with WSSPI yielded a highly accurate predictive model of IA growth. On validation in future cohorts, these metrics may aid in early identification of IA growth and understanding of IA remodeling mechanisms.


  • Reconstruction of carotid stenosis hemodynamics based on guidewire pressure data and computational modeling

    by Huy Dinh, Fernando Vinuela, Viktor Szeder, Kasra Khatibi, Lucido Ponce Mejia, Aichi Chien

    A comparative analysis between intravascular guidewire-obtained and computational fluid dynamic (CFD) flow velocity and pressure data using simplified carotid stenosis models was performed. This information was used to evaluate the viability of using guidewire pressure data to provide inlet conditions for CFD flow, and to study the relationship between stenotic length and hemodynamic behavior. Carotid stenosis models differing in diameter and length were prepared and connected to a vascular pulsatile flow simulator. Time-dependent flow velocity and pressure measurements were taken by microcatheter guidewires and compared with CFD data. Guidewire and CFD-generated pressure profiles matched closely in all measurement locations. The guidewire was unable to reliably measure flow velocity at areas associated with higher CFD flow velocities (r = 0.92). CFD results showed that an increased length of stenosis generated expansive regions of elevated wall shear stress (WSS) within and distal to the stenosis. Low WSS was found immediately outside the stenosis outlet. An increase in stenotic length produced higher flow velocities with minimal lengthening of the distal high velocity flow jet due to faster dissipation of translational kinetic energy through turbulence. We found the accuracy of guidewire-obtained velocity measurements is limited to regions unaffected by disturbed flow. WSS and turbulence behavior distal to the stenosis may be important markers to evaluate the severity of atherosclerotic progression as a function of stenotic length. Graphical abstract


  • Abstract TMP6: Computational Hemodynamic Analysis Of Intra-Aneurysmal Effects Due To Flow Diverter Stent Deployment Conformation

    by Huy Dinh, Aichi Chien

    Introduction: Inflow blockage of aneurysms treated with flow diverter stents is dependent on the deployed braid angle (ϕ)—the angle between the yarns which comprise the stent braids and the longitudinal axis of the braid. We utilized computational fluid dynamic (CFD) analysis to examine the effects of braid angle on intra-aneurysmal hemodynamic parameters associated with long-term treatment success. Methods: Two flow diverter stents measuring 3.5 mm in diameter, each containing 88 strands with ϕ = 10° and ϕ = 35° were constructed and deployed into a patient model of an internal carotid artery saccular aneurysm containing pulsatile blood flow. Intra-aneurysmal flow velocity, pulsatility index (PI), turbulence, vorticity, and wall shear stress (WSS) parameters were obtained and compared for the two braid angles. Results: Reducing ϕ from 35° to 10° resulted in -2.59%, -1.92%, and -1.41% changes in systolic bulk velocity, and -1.79%, +0.57%, and -1.65% changes in PI at the aneurysm neck, body, and dome respectively. Vorticity changes were insignificant. High turbulence extending through the aneurysm neck peaked approximately 0.04 s later in systole, and was located closer to the parent vessel outlet when ϕ = 10°. Elevated intra-aneurysmal WSS was concentrated at the neck and body on the side of the parent vessel outlet for both ϕ = 10° and ϕ = 35°. Regions of WSS in excess of 10 Pa stretched higher into the aneurysm body when ϕ = 35°. Conclusion: Stenting at a lower ϕ resulted in higher blockage of flow and better reduction of WSS for initiating and facilitating long term intra-aneurysmal thrombosis. CFD analysis incorporating precise reconstruction of the stent deployment conformation into patient models can provide detailed visualization of flow parameters for assessing potential treatment efficacy throughout the diagnostic and treatment phases of patient care. Download figure

  • Abstract P304: A Novel Method for Modeling Flow in Cerebral Vasculature Diagnostics

    by Huy Dinh

    Introduction: We examined the viability of pairing wire-obtained flow pressure data with computational fluid dynamic (CFD) analysis for accurate patient-specific 3D reconstruction of flow through cerebral vessels—an approach that provides comprehensive velocity data and other flow parameters to assist the preventative diagnosis of cerebral stenosis. Methods: Two physical phantom models of a cerebral stenosis—differing in regard to vascular morphology at and around the stenosis—were prepared, filled with physiological saline and connected individually to a flow pump (Vascular Simulations LLC Left Heart Replicator) applying pulsatile flow. Pressure measurements were taken upstream of the stenosis by microcatheter-guided wires to define an inlet boundary condition for CFD analysis. Pressure and velocity at 2 cm proximal to stenosis, the stenosis inlet, the stenosis outlet, and 2 cm distal to stenosis were measured to validate the CFD simulated flow. Results: Excellent agreement was observed between CFD and wire-measured time-dependent flow pressure, with the expected pulsatile behavior observed at each location. Between the two methods, differences in maximum systolic pressures ranged between |0.73±0.72|% and |3.90±0.74|%. Differences in minimum diastolic pressures ranged between |1.79±1.33|% and |9.08±1.42|%. Velocity data from wire measurements lacked pulsatile behavior and showed differences ranging between |2.93±5.20|% and |120.10±2.91|% from CFD-obtained measurements, which did show correct pulsatile behavior. Larger discrepancies were strongly associated with areas of higher CFD predicted velocities (r=0.86). Conclusion: Guidewire flow measurements provided CFD analysis with accurate inlet boundary conditions and validated CFD simulation results. CFD analysis allowed for detailed visualization of key flow parameters that may be difficult to physically measure—such as velocity—that are relevant for understanding risk factors associated with cerebral stenosis on a case-by-case basis.

  • Abstract P531: Cerebral Blood Flow Analysis Using Flow Wire Measurements and CFD Analysis

    by Aichi Chien, Huy Dinh, Viktor Szeder, Fernando Vinuela

    Introduction: Clinical reports show that cerebral blood flow conditions are indicative of cerebral vascular disease. While methods for characterizing cerebral vascular flow have been extensively reported in the past, comparative analyses between direct flow measurements (DM) and computational flow dynamic (CFD) analysis remain limited. We hypothesize that flow data can be reliably measured both directly and through CFD in normal vessels. Methods: A left heart replicator was used as a realistic cardiac pump which maintained systolic pressure at 120 mmHg and diastolic pressure at 80 mmHg. A stenotic model with 50% stenosis for the ICA was connected to the replicator. A ComboWire was used for DM and recorded flow pressure and velocity. CFD was used to study flow. Results: In areas at the proximal end of the stenosis, the pressure and flow velocity derived from DM and CFD were in good agreement. At the end of systole and diastole, DM pressure were 145.42 mmHg and 73.53 mmHg, respectively. CFD simulation for the same system obtained the pressure at the end of systole and diastole of 147.16 mmHg and 74.64 mmHg, respectively. The velocity data collected from DM was at 15.40 cm/s and 7.74 cm/s for systolic flow and mean flow velocity. CFD measured flow was 17.85 cm/s and 11.37 cm/s, respectively. In areas at the distal end of the stenosis, pressure data showed good agreement between DM and CFD analysis. The DM were 138 and 70.81 mmHg at the end of systole and diastole, respectively; CFD simulation yielded 145.95 and 74.51 mmHg, respectively. Variations in the velocity data were observed at this location (Fig, pink arrows). Conclusion: DM of pressure showed good agreement with CFD simulation in all areas of the vessel. DM of velocity using the flow wire were highly affected by location of the measurement. CFD analysis can provide more consistent flow data for flow information collection along the vasculature. Download figure


  • A physical phantom for amine chemical exchange saturation transfer (CEST) MRI

    by Jingwen Yao, Chencai Wang, Catalina Raymond, Blake Bergstrom, Xing Chen, Kaveri Das, Huy Dinh, Zoe S. Kim, Angela N. Le, Matthew W. J. Lim, et al.

    Objective To develop a robust amine chemical exchange saturation transfer (CEST) physical phantom, validate the temporal stability, and create a supporting software for automatic image processing and quality assurance. Materials and methods The phantom was designed as an assembled laser-cut acrylic rack and 18 vials of phantom solutions, prepared with different pHs, glycine concentrations, and gadolinium concentrations. We evaluated glycine concentrations using ultraviolet absorbance for 70 days and measured the pH, relaxation rates, and CEST contrast for 94 days after preparation. We used Spearman’s correlation to determine if glycine degraded over time. Linear regression and Bland–Altman analysis were performed between baseline and follow-up measurements of pH and MRI properties. Results No degradation of glycine was observed (p > 0.05). The pH and MRI measurements stayed stable for 3 months and showed high consistency across time points (R2 = 1.00 for pH, R1, R2, and CEST contrast), which was further validated by the Bland–Altman plots. Examples of automatically generated reports are provided. Discussion We designed a physical phantom for amine CEST-MRI, which is easy to assemble and transfer, holds 18 different solutions, and has excellent short-term chemical and MRI stability. We believe this robust phantom will facilitate the development of novel sequences and cross-scanners validations.