Biao Si
Research Subjects
Biao Si has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Zhenglun Alan Wei
Department of Biomedical Engineering, Worcester Polytechnic Institute 1 , Worcester, Massachusetts 01609
3 shared publications - Maduka Maduka
Department of Biomedical Engineering, Worcester Polytechnic Institute 1 , Worcester, Massachusetts 01609
2 shared publications - Zhongqiang Zhang
Department of Mathematical Sciences, Worcester Polytechnic Institute, Worcester, MA 01609 USA
2 shared publications Bin Qiao
1 shared publicationCarter Allen
Department of Biomedical Engineering, Worcester Polytechnic Institute 1 , Worcester, Massachusetts 01605
1 shared publication- Fatemeh Salargarna
Department of Biomedical Engineering, Worcester Polytechnic Institute 1 , Worcester, Massachusetts 01609
1 shared publication
Latest Publications
- 1 August 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (8)
Modal complexity and power loss in patient-specific Fontan cavopulmonary connection flow
Power loss (PL) across the total cavopulmonary connection (TCPC) varies among Fontan patients, but scalar energetic metrics cannot describe how unsteady flow structures organize within the connection. We evaluated whether volume-weighted proper orthogonal decomposition (POD) provides structure-resolved descriptors of TCPC flow organization and whether truncated POD reconstructions preserve PL. Fifteen patient-specific TCPC anatomies were reconstructed from cardiac magnetic resonance imaging and simulated using unsteady computational fluid dynamics with pulsatile caval inflow and clinically measured pulmonary flow splits. POD was applied to velocity snapshots from the final cardiac cycle. We quantified modal organization using the energy-capture mode count Nε and normalized Shannon entropy H. Statistical analyses enabled comparison of PL, indexed power loss (iPL), and POD metrics. PL was associated with broader POD spectra: PL correlated with N0.995 (ρs = 0.812, p-value = 0.0002) and H(ρs = 0.650, p-value = 0.0108). In contrast, iPL associations were weaker and less precise, including iPL–N0.995 (ρs = 0.479, p-value = 0.075) and iPL–H (ρs = 0.218, p-value = 0.428). PL reconstruction error decreased from a median of 1.59% at N0.995 to below 0.01% at N0.999. These results show that volume-weighted POD identifies differences in TCPC fluctuation organization that are more clearly associated with PL than iPL, and that PL preservation provides a useful metric-level test for POD truncation.
- 1 August 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (8)
Modal complexity and power loss in patient-specific Fontan cavopulmonary connection flow
Power loss (PL) across the total cavopulmonary connection (TCPC) varies among Fontan patients, but scalar energetic metrics cannot describe how unsteady flow structures organize within the connection. We evaluated whether volume-weighted proper orthogonal decomposition (POD) provides structure-resolved descriptors of TCPC flow organization and whether truncated POD reconstructions preserve PL. Fifteen patient-specific TCPC anatomies were reconstructed from cardiac magnetic resonance imaging and simulated using unsteady computational fluid dynamics with pulsatile caval inflow and clinically measured pulmonary flow splits. POD was applied to velocity snapshots from the final cardiac cycle. We quantified modal organization using the energy-capture mode count Nε and normalized Shannon entropy H. Statistical analyses enabled comparison of PL, indexed power loss (iPL), and POD metrics. PL was associated with broader POD spectra: PL correlated with N0.995 (ρs = 0.812, p-value = 0.0002) and H(ρs = 0.650, p-value = 0.0108). In contrast, iPL associations were weaker and less precise, including iPL–N0.995 (ρs = 0.479, p-value = 0.075) and iPL–H (ρs = 0.218, p-value = 0.428). PL reconstruction error decreased from a median of 1.59% at N0.995 to below 0.01% at N0.999. These results show that volume-weighted POD identifies differences in TCPC fluctuation organization that are more clearly associated with PL than iPL, and that PL preservation provides a useful metric-level test for POD truncation.
- 1 January 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (1)
Evaluation of reduced-order models for pulsatile flow over a two-dimensional backward-facing step
Reduced-order modeling (ROM) enables efficient analysis of unsteady separated flows, but most formulations are assessed under steady or purely periodic forcing and do not reflect physiologically realistic pulsatility. Here, two-dimensional backward-facing step simulations are performed under sinusoidal inflow and a physiologically inspired pulsatile waveform with intermittent bursts, including a sinusoidal control case matched to the pulsatile inflow in both frequency and amplitude. Proper orthogonal decomposition (POD) and dynamic mode decomposition (DMD) are applied to velocity and out-of-plane vorticity fields, and reconstruction accuracy and compactness are quantified, including DMD-I and DMD-E mode-ranking variants. In all cases, coherent vortices form downstream of the step due to separated shear-layer roll-up consistent with Kelvin–Helmholtz shear-layer dynamics. The forcing frequency and its harmonics are present in the modal spectra for all cases; however, cycle-to-cycle instantaneous fields are not identical, indicating organized dynamics without strict phase locking. Under pulsatile inflow, vortex interactions intensify through co-rotation, deformation, and merging, and an additional low-frequency component near 0.29 Hz appears across higher modes, consistent with slow modulation associated with waveform intermittency. POD provides the most robust balance of compression and accuracy, whereas DMD performs well for sinusoidal inflow but exhibits practical error plateaus around 10% under pulsatile forcing despite improved ranking strategies. Overall, waveform shape and intermittency increase effective flow dimensionality and challenge global linear ROMs, highlighting the need for localized or time-windowed reduction strategies to enable mechanistic insight in pulsatile biomedical flows and cardiovascular applications.
- 1 January 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (1)
Evaluation of reduced-order models for pulsatile flow over a two-dimensional backward-facing step
Reduced-order modeling (ROM) enables efficient analysis of unsteady separated flows, but most formulations are assessed under steady or purely periodic forcing and do not reflect physiologically realistic pulsatility. Here, two-dimensional backward-facing step simulations are performed under sinusoidal inflow and a physiologically inspired pulsatile waveform with intermittent bursts, including a sinusoidal control case matched to the pulsatile inflow in both frequency and amplitude. Proper orthogonal decomposition (POD) and dynamic mode decomposition (DMD) are applied to velocity and out-of-plane vorticity fields, and reconstruction accuracy and compactness are quantified, including DMD-I and DMD-E mode-ranking variants. In all cases, coherent vortices form downstream of the step due to separated shear-layer roll-up consistent with Kelvin–Helmholtz shear-layer dynamics. The forcing frequency and its harmonics are present in the modal spectra for all cases; however, cycle-to-cycle instantaneous fields are not identical, indicating organized dynamics without strict phase locking. Under pulsatile inflow, vortex interactions intensify through co-rotation, deformation, and merging, and an additional low-frequency component near 0.29 Hz appears across higher modes, consistent with slow modulation associated with waveform intermittency. POD provides the most robust balance of compression and accuracy, whereas DMD performs well for sinusoidal inflow but exhibits practical error plateaus around 10% under pulsatile forcing despite improved ranking strategies. Overall, waveform shape and intermittency increase effective flow dimensionality and challenge global linear ROMs, highlighting the need for localized or time-windowed reduction strategies to enable mechanistic insight in pulsatile biomedical flows and cardiovascular applications.
- 1 February 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (2)
Impact of upstream flow mixing on computational hemodynamic evaluation of total cavopulmonary connections
Hemodynamics in total cavopulmonary connections (TCPCs) are closely linked to patient outcomes. Previous studies have simplified assessments by focusing solely on the TCPC itself, overlooking the effects of upstream flow mixing. Consequently, the impact of upstream flow mixing on TCPC hemodynamics remains poorly understood. In this study, we quantified for the first time the effect of flow mixing from all vessels upstream of the TCPC. Hemodynamic metrics were obtained using a cutting-edge computational platform that considers patient-specific TCPC anatomy, peripheral vessels upstream of the TCPC, and corresponding flow data. Results showed that ignoring upstream flow mixing from the upper and lower body could lead to significant errors in calculating hepatic flow distribution—5.0% ± 5.9% and 14.4% ± 10.9%, respectively—but not in power loss (PL) or resistance throughout the TCPC. Interestingly, flow mixing from the upper body induces an additional 25.8 ± 16.8% PL beyond the losses within the TCPC itself, which could inspire innovative clinical treatments to improve patient outcomes. Our study underscores the critical need to account for upstream flow mixing from both the upper and lower body in TCPC hemodynamic assessments. Accurately simulating this mixing requires estimating the flow rates of peripheral vessels. We explored radius-based flow-splitting methods to achieve this, finding that the square law aligns most closely with patient data for lower-body vessels, while the fourth-power law yields satisfactory results for upper-body vessels. These findings could significantly impact clinical practices in Fontan hemodynamic assessment.
- 1 February 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (2)
Impact of upstream flow mixing on computational hemodynamic evaluation of total cavopulmonary connections
Hemodynamics in total cavopulmonary connections (TCPCs) are closely linked to patient outcomes. Previous studies have simplified assessments by focusing solely on the TCPC itself, overlooking the effects of upstream flow mixing. Consequently, the impact of upstream flow mixing on TCPC hemodynamics remains poorly understood. In this study, we quantified for the first time the effect of flow mixing from all vessels upstream of the TCPC. Hemodynamic metrics were obtained using a cutting-edge computational platform that considers patient-specific TCPC anatomy, peripheral vessels upstream of the TCPC, and corresponding flow data. Results showed that ignoring upstream flow mixing from the upper and lower body could lead to significant errors in calculating hepatic flow distribution—5.0% ± 5.9% and 14.4% ± 10.9%, respectively—but not in power loss (PL) or resistance throughout the TCPC. Interestingly, flow mixing from the upper body induces an additional 25.8 ± 16.8% PL beyond the losses within the TCPC itself, which could inspire innovative clinical treatments to improve patient outcomes. Our study underscores the critical need to account for upstream flow mixing from both the upper and lower body in TCPC hemodynamic assessments. Accurately simulating this mixing requires estimating the flow rates of peripheral vessels. We explored radius-based flow-splitting methods to achieve this, finding that the square law aligns most closely with patient data for lower-body vessels, while the fourth-power law yields satisfactory results for upper-body vessels. These findings could significantly impact clinical practices in Fontan hemodynamic assessment.