DDDaisy Das

Daisy Das

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daisy Das has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Hierarchical MnO/rGO-IrOx Nanocomposite Architecture for Sensitive Detection of Chlorate in Water

    by Daisy Das, Alan O’RIordan, Han Shao

    Chlorate is an emerging contaminant originating from industrial processes, disinfectants, and water treatment applications, necessitating the development of rapid and reliable detection methods for environmental monitoring. Conventional chlorate analysis typically relies on laboratorybased techniques that require expensive instrumentation, extensive sample preparation, and skilled operators, limiting their suitability for on-site measurements. In this work, an electrochemical chlorate sensor based on a MnO/rGO–IrOx modified interdigitated gold microband electrode is presented. The hierarchical nanocomposite architecture enhances the electroactive surface area and promotes efficient charge transfer, resulting in high selectivity enhanced sensitivity, improved reproducibility. Using square wave voltammetry, the sensor exhibited a sensitivity of 0.03124 µA ppm-1, a limit of detection of 0.375 ppm. The developed platform demonstrated good selectivity toward chlorate in the presence of common interfering ions, including NO3-, NH4+, SO42-, Mg2+, Fe2+, Zn2+, and K+. These results highlight the potential of the proposed MnO/rGO–IrOx functionalized microelectrode as a simple and cost-effective platform for chlorate sensing and future environmental monitoring applications.

  • Interferent-Free Electrochemical Detection of Nitrate in Water Using Copper–Cobalt-Based Sensor

    by Daisy Das, Alan O'RIordan, Han Shao

    Nitrate contamination in water is a significant global concern, prompting regulatory bodies such as the European Union to set a maximum permissible limit of 44 mg/L in drinking water. However, conventional laboratory-based detection methods are time-consuming and require specialized expertise, while chemical electrode systems often suffer from drawbacks such as frequent recalibration and ion cross sensitivity, limiting their suitability for long-term and on-site monitoring. In response to these challenges, we present a novel and cost-effective electrochemical sensor based on a copper–cobalt-based electrochemical sensor for reliable nitrate detection. The sensor exhibits a remarkable true detection limit of 0.19 µM and a limit of quantification of 4.41 µM and demonstrates high selectivity even in the presence of commonly interfering ions such as Mg2+, SO42-, Zn2+, K+, NH4+, Fe2+, and Na+. Owing to its sensitivity, selectivity, and portability, the developed sensor offers a promising solution for real-time, on-site monitoring of nitrate concentrations in both water and soil samples.


  • Open Access

    Interferent Free Electrochemical Detection of Nitrate in Water Using Copper–Cobalt based Sensor

    by Daisy Das, Han Shao, Alan O'RIordan

    Nitrate contamination in water is a significant global concern, prompting regulatory bodies such as the European Union to set a maximum permissible limit of 44 mg/L in drinking water. However, conventional laboratory-based detection methods are time-consuming and require specialized expertise, while chemical electrode systems often suffer from drawbacks such as frequent recalibration and ion cross-sensitivity, limiting their suitability for long-term and on-site monitoring. In response to these challenges, we present a novel and cost-effective electrochemical sensor based on a copper–cobalt based electrochemical sensor for reliable nitrate detection. The sensor exhibits a remarkable detection limit of 0.19 µM and demonstrates high selectivity even in the presence of commonly interfering ions such as Mg²⁺, SO₄²⁻, Zn²⁺, K⁺, NH₄⁺, Fe²⁺, and Na⁺. Owing to its sensitivity, selectivity, and portability, the developed sensor offers a promising solution for real-time, on-site monitoring of nitrate concentrations in both water and soil samples