Eduardo Simón-Pérez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Eduardo Simón-Pérez has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Alejandro Fernández-Gibello
Clínica Vitruvio, C/María de Guzmán 47, 28003 Madrid, Spain
1 shared publication - Alfonso Martínez-Nova
Department of Nursing, University of Extremadura, 10600 Plasencia, Spain
1 shared publication - Felice Galluccio
Fisiotech Lab Studio, Rheumatology and Pain Management, 50136 Firenze, Italy
1 shared publication - Francisco Martínez-Pérez
Clínica Vitruvio, C/ María de Guzmán 47, 28003 Madrid, Spain
1 shared publication - Gabriel Camuñas-Nieves
Clínica Vitruvio, C/María de Guzmán 47, 28003 Madrid, Spain
1 shared publication - Mario Fajardo Perez
Ultradissection Group. Madrid (Spain), Spain
1 shared publication
Latest Publications
- Open Access
- 28 July 2025
- Published by MDPI AG in Healthcare
- Vol. 13 (15) , 1838
Continuous Radiofrequency for Morton’s Neuroma: Is There Complete Ablation? A Preliminary Report
Background and Objectives: Morton’s neuroma is a painful foot condition that can be treated with continuous radiofrequency. However, its efficacy is not always optimal, with failure rates of 15–20%. It has been suggested that these failures may be due to incomplete nerve ablation, allowing for nerve regeneration and persistent pain. So, the aim of this study was to assess the histological effects of continuous radiofrequency on the nerves affected by Morton’s neuroma. Materials and Methods: The effect of continuous radiofrequency was evaluated in two patients with Morton’s neuroma, which required open surgery excision. In both cases, radiofrequency with a standard protocol was applied ex vivo, following the surgical excision of the neuroma. A TLG10 RF generator (90 °C, 90 s) with a monopolar needle with a 0.5 cm active tip was used. Subsequently, the samples were histologically analyzed to determine the degree of nerve ablation. Results: Histological analysis showed homogeneous focal necrosis in both cases, with lesion depths of 2.4 mm and 3.18 mm. However, areas of intact nerve tissue were identified at the periphery of the neuroma, suggesting incomplete ablation. Conclusions: The findings indicate that continuous radiofrequency does not guarantee total nerve ablation, which could explain recurrence in some cases. Intraoperative neurophysiological monitoring could be key to optimizing the procedure, ensuring complete interruption of nerve conduction and improving treatment efficacy.
- 28 July 2025
- Published by MDPI AG in Healthcare
- Vol. 13 (15) , 1838
Open AccessContinuous Radiofrequency for Morton’s Neuroma: Is There Complete Ablation? A Preliminary Report
Background and Objectives: Morton’s neuroma is a painful foot condition that can be treated with continuous radiofrequency. However, its efficacy is not always optimal, with failure rates of 15–20%. It has been suggested that these failures may be due to incomplete nerve ablation, allowing for nerve regeneration and persistent pain. So, the aim of this study was to assess the histological effects of continuous radiofrequency on the nerves affected by Morton’s neuroma. Materials and Methods: The effect of continuous radiofrequency was evaluated in two patients with Morton’s neuroma, which required open surgery excision. In both cases, radiofrequency with a standard protocol was applied ex vivo, following the surgical excision of the neuroma. A TLG10 RF generator (90 °C, 90 s) with a monopolar needle with a 0.5 cm active tip was used. Subsequently, the samples were histologically analyzed to determine the degree of nerve ablation. Results: Histological analysis showed homogeneous focal necrosis in both cases, with lesion depths of 2.4 mm and 3.18 mm. However, areas of intact nerve tissue were identified at the periphery of the neuroma, suggesting incomplete ablation. Conclusions: The findings indicate that continuous radiofrequency does not guarantee total nerve ablation, which could explain recurrence in some cases. Intraoperative neurophysiological monitoring could be key to optimizing the procedure, ensuring complete interruption of nerve conduction and improving treatment efficacy.