Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Abdullah Al Noman has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Chitosan-Ion Imprinted Polymer Based Modal Interferometer for Ultra-Trace Cd 2+ Detection

    by Xujie Wang, Abdullah Al Noman, Maoqi Liu, Changyuan Yu

    A low-cost, easily fabricated, and compact modal interferometric sensor coated with chitosan-cadmium ion imprinted polymer (CS-Cd²⁺IP) is proposed and experimentally demonstrated for ultra-trace cadmium detection. The interferometer is constructed by sequentially splicing fixed lengths of multimode fiber (MMF) and no-core fiber (NCF) between single-mode fibers (SMFs). The formation of the CS-Cd²⁺IP layer for specific cadmium binding is achieved by modifying the interferometer surface with a CS-Cd²⁺ compound and 0.2% epichlorohydrin (ECH) solution. The sensor exhibits a linear cadmium sensitivity of 1.1528 nm/parts per trillion (ppt) and a limit of detection (LoD) of 0.0695 ppt within a rapid and stable response range of 0 to 1 ppt. The sensor demonstrates significantly enhanced selectivity towards Cd²⁺ while minimizing responses to other heavy metal ions (HMIs). The effects of environmental factors such as pH and temperature are investigated to minimize measurement errors and improve accuracy. Two additional sensors are fabricated using the same process to demonstrate the reproducibility of the proposed cadmium sensing scheme.


  • Open Access

    Graphene oxide modified U-shaped polymer optical fiber biosensor for hemoglobin sensing

    by Abdullah Al Noman, Xin Cheng, Sinead O'KEeffe


  • SMNS structure based fiber optic interferometer for cadmium detection

    by Xujie Wang, Abdullah Al Noman, Yifan Liu, Changyuan Yu

    A cost-effective, easy-to-manufacture, compact, and reliable single-mode fiber/ multimode fiber/ no-core fiber/ single-mode fiber (SMNS) structure based interferometer is proposed for the detection of cadmium ions (Cd2+). This setup involves splicing a segment of multimode fiber (MMF) and no-core fiber (NCF) between a single-mode fiber (SMF), followed by a functionalization procedure with a composite of graphene oxide (GO)-cysteamine (MEA) and chitosan (CS)-Cd2+ imprinted polymer (Cd2+IP). The sensitivity of the sensors has been calculated by monitoring the interference minima. Three identical probes have been fabricated to ensure the duplicability and the highest sensing sensitivity is measured at -0.1211 nm/ parts per billion (ppb) in the cadmium detection range of 0 ppb to 10 ppb with a response time of 90 s. The probe demonstrates a high selectivity for Cd2+ compared to other heavy metal ions. The response of the probe in various pH solutions has been investigated to minimize the sensing error. Further, the temperature crosstalk is eliminated by assessing the response of a fiber Bragg grating (FBG).


  • Open Access

    Label-Free DNA Detection Using Etched Tilted Bragg Fiber Grating-Based Biosensor

    by Abdullah Al Noman, Jitendra Narayan Dash, Abdullah Al Maruf, Cheng Xin, Hwa-Yam Tam, Changyuan Yu

    A label-free-based fiber optic biosensor based on etched tilted Bragg fiber grating (TFBG) is proposed and practically demonstrated. Conventional phase mask technic has been utilized to inscribe tilted fiber Bragg grating with a tilt angle of 10°, while the etching has been accomplished with hydrofluoric acid. A composite of polyethylenimine (PEI)/poly(acrylic acid) (PAA) has been thermally deposited on the etched TFBG, followed by immobilization of probe DNA (pDNA) on this deposited layer. The hybridization of pDNA with the complementary DNA (cDNA) has been monitored using wavelength-dependent interrogation. The reproducibility of the probes has been demonstrated by fabricating three identical probes and their response has been investigated for cDNA concentration ranging from 0 μM to 3 μM. The maximum sensitivity has been found to be 320 pm/μM, with the detection limit being 0.65 μM. Furthermore, the response of the probes towards non-cDNA has also been investigated in order to establish its specificity.


  • Rapid and sensitive detection of aqueous ammonia harnessing nanocomposite functionalized tilted fiber Bragg grating

    by Pin Xu, Yifan Liu, Abdullah Al Noman, Xin Cheng, Yujian Li, Changyuan Yu

    A high sensitive aqueous ammonia sensor based on tilted fiber Bragg grating (TFBG) had been reported. The sensors were fabricated by a 10 ° TFBG coated by a membrane receptor named as Polyaniline/Graphene oxide on the surface of the fiber. The correlative concentrations of aqueous ammonia were demodulated by global monitoring of the envelope area of cladding modes in the transmitted spectrum of the TFBG. Tests have shown that the proposed sensor can provide a linear and rapid response of aqueous ammonia within 22 seconds, in a concentration range from 1-12 ppm. Moreover, the limit of detection can even reach 0.08 ppm, through the theoretical analysis of our experimental results. The proposed sensor has good performance, is easy to manufacture and of small size, making it a good choice for real-time, in-situ, label-free detection of aqueous ammonia in the future.


  • Optical Fiber based Nitrate Sensor using Mach-Zehnder Interferometer

    by Abdullah Al Noman, Jitendra Narayan Dash, Xin Cheng, Changyuan Yu

    An easily assembled and highly sensitive Mach-Zehnder interferometer (MZI) utilized fiber optic sensor coated with (polyvinyl alcohol) PVA and carbon nanotubes (CNTs)/PVA is proposed here for nitrate sensing. The sensor showed a sensitivity of 33.7 pm/ppm concerning nitrate solutions of 0 ppm to 50 ppm.

  • Mach-Zehnder interferometer based fiber-optic nitrate sensor

    by Abdullah Al Noman, Jitendra Narayan Dash, Xin Cheng, Hwa-Yam Tam, Changyuan Yu

    A biocompatible, reliable and quick responsive fiber-optic sensor based on Mach-Zehnder interferometer (MZI) is demonstrated for nitrate analytes tracing. The sensor was constructed by collapsing the air holes of a short length photonic crystal fiber (PCF) with the single-mode fibers (SMFs) on both ways. The proposed sensor has been coated with a graphene-PVA (polyvinyl alcohol) membrane using the thermal coating technique to make the sensor attractive to the nitrate ions in the aqueous solution. The maximum response is found to be 0.15 pm/ppm on the nitrate measurement scale of 0 ppm to 100 ppm with an average reaction time of ∼10 s. Also, a short length of FBG (fiber Bragg grating) is implanted with SMF to improve the sensing accuracy of the presented sensor.


  • PCF based modal interferometer for lead ion detection

    by Abdullah Al Noman, Jitendra Narayan Dash, Xin Cheng, Hwa-Yaw Tam, Changyuan Yu

    A compact, reliable, and fast responsive PCF (photonic crystal fiber) based modal interferometric sensor for lead ion detection is proposed and experimentally demonstrated. The sensor has been fabricated by splicing a small section of PCF with SMF (single mode fiber) followed by collapsing the air holes of PCF at its tip. The interferometer is dip coated with chitosan-PVA (polyvinyl alcohol) and glutathione functionalized gold nanoparticles. Three probes have been fabricated, and the maximum sensitivity has been found to be 0.031 nm/ppb for lead ions whereas the detection range has been considered from 0 ppb to 50 ppb. The probe has been found to have a faster response time of ∼ 10 s. Furthermore, the sensor has been found to be less responsive towards other heavy metal ions, thereby demonstrating its selectivity towards lead ions. Besides, a section of FBG (fiber Bragg grating) has been embedded into the interferometer and the temperature response of FBG peak along with interference spectra has been investigated for better accuracy.


  • Fiber optic lead ion (Pb2+) sensor using chitosan diaphragm based Fabry-Pérot interferometer

    by Abdullah Al Noman, Jitendra Narayan Dash, Xin Cheng, Changyuan Yu

    A highly sensitive Fabry-Pérot interferometer (FPI) based on chitosan coated capillary is demonstrated for lead sensing. The proposed sensor exhibits a sensitivity of -0.091 nm/ppm for lead concentrations varying from 0 ppm to 30 ppm.