Sairaman Saikrithika
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sairaman Saikrithika has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Annamalai Senthil Kumar
Vellore Institute of Technology
8 shared publications Annamalai Senthil Kumar
Carbon Dioxide and Green Technology Research Centre
4 shared publications- Young-Joon Kim
Department of Electronic Engineering, Gachon University, Seongnam 13120, Republic of Korea
3 shared publications Bose Dinesh
2 shared publications- Kandaswamy Theyagarajan
Department of Electronic Engineering, Gachon University, Seongnam 13120, Republic of Korea
2 shared publications Anlin Shaju
Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology University, Vellore 632014, India
1 shared publication
Latest Publications
- Open Access
- 9 November 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (11) , 252
Redox-Active Molecularly Imprinted Polymers for Electrochemical Sensor-Based Health Monitoring: Moving Closer to Real-Time Measurements
Molecularly imprinted polymers (MIPs) are robust synthetic recognition elements for electrochemical health monitoring, offering chemical stability, tunable selectivity, and compatibility with miniaturized devices. Conventional MIP sensors, however, often rely on external redox probes or the intrinsic electroactivity of the target. This dependence can add assay steps, make signals sensitive to probe diffusion, and restrict the detection of non-electroactive analytes, complicating rapid or continuous measurement in complex biological samples. Redox-active MIPs offer an alternative by integrating molecular recognition and electrochemical signal generation within the sensing interface. This review examines how redox components are incorporated into MIP architecture and how target binding modulates their electrochemical responses. It covers systems incorporating Prussian blue and related hexacyanoferrates, methylene blue and other redox-active polymers, ferrocene, copper-containing materials, metal nanoparticles, and redox-active metal oxides, with applications to biomarkers, metabolites, hormones, therapeutic agents, and other health-relevant analytes. Particular attention is given to the coupling between recognition and redox transduction, highlighting how redox-component positioning, binding-site accessibility, and interfacial electron transfer influence signal generation, as well as mass transport, electrocatalysis, regeneration, and selectivity in complex biological matrices. Remaining challenges include maintaining binding-site accessibility and efficient electron transfer, controlling redox-component placement, improving matrix tolerance and long-term stability, and adapting these interfaces for wearable and point-of-care devices. Future progress will require application-oriented evaluation of analytical performance, selectivity, measurement time, and reusability, alongside the integration of recognition chemistry, redox mechanisms, biofluid handling, and device design to support reliable, continuous, and decentralized health monitoring, including rapid measurements and, where demonstrated, continuous and decentralized monitoring.
- 9 November 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (11) , 252
Open AccessRedox-Active Molecularly Imprinted Polymers for Electrochemical Sensor-Based Health Monitoring: Moving Closer to Real-Time Measurements
Molecularly imprinted polymers (MIPs) are robust synthetic recognition elements for electrochemical health monitoring, offering chemical stability, tunable selectivity, and compatibility with miniaturized devices. Conventional MIP sensors, however, often rely on external redox probes or the intrinsic electroactivity of the target. This dependence can add assay steps, make signals sensitive to probe diffusion, and restrict the detection of non-electroactive analytes, complicating rapid or continuous measurement in complex biological samples. Redox-active MIPs offer an alternative by integrating molecular recognition and electrochemical signal generation within the sensing interface. This review examines how redox components are incorporated into MIP architecture and how target binding modulates their electrochemical responses. It covers systems incorporating Prussian blue and related hexacyanoferrates, methylene blue and other redox-active polymers, ferrocene, copper-containing materials, metal nanoparticles, and redox-active metal oxides, with applications to biomarkers, metabolites, hormones, therapeutic agents, and other health-relevant analytes. Particular attention is given to the coupling between recognition and redox transduction, highlighting how redox-component positioning, binding-site accessibility, and interfacial electron transfer influence signal generation, as well as mass transport, electrocatalysis, regeneration, and selectivity in complex biological matrices. Remaining challenges include maintaining binding-site accessibility and efficient electron transfer, controlling redox-component placement, improving matrix tolerance and long-term stability, and adapting these interfaces for wearable and point-of-care devices. Future progress will require application-oriented evaluation of analytical performance, selectivity, measurement time, and reusability, alongside the integration of recognition chemistry, redox mechanisms, biofluid handling, and device design to support reliable, continuous, and decentralized health monitoring, including rapid measurements and, where demonstrated, continuous and decentralized monitoring.
- Open Access
- 20 February 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (2) , 267
MXene- and MOF-Based Hydrogels: Emerging Platforms for Electrochemical Biosensing and Health Monitoring
Smart healthcare is rapidly emerging as a transformative paradigm, enabling simultaneous health monitoring, therapeutic intervention, and early prediction of disease onset. In this context, electrochemical monitoring systems have attracted growing interest due to their cost-effectiveness, ease of operation, miniaturization and compatibility with wearable platforms. Accordingly, conductive hydrogel-based electrochemical (bio)sensors have gained significant attention for health monitoring owing to their soft mechanical properties, high water content, excellent biocompatibility, and ability to form intimate, conformal interfaces with biological tissues. Their three-dimensional polymeric networks facilitate efficient ion transport and mechanical flexibility, making them particularly suitable for wearable and noninvasive sensing and monitoring applications. However, the intrinsically limited conductivity and catalytic activity of pristine hydrogels often constrain their electrochemical performance. To overcome these limitations, functional nanomaterials such as metal–organic frameworks (MOFs) and MXene (MX) nanosheets have been increasingly integrated into hydrogel matrices to enhance conductivity and electrochemical activity. This review provides a comprehensive and critical comparison of recent advances in MOF- and MX-integrated conductive hydrogels for electrochemical health monitoring. In addition to material design strategies and sensing performance, emerging trends in data-driven sensing aimed at improving signal interpretation and multi-analyte discrimination are systematically discussed. Key challenges related to long-term stability, biocompatibility, scalability, and intelligent system integration are critically assessed, and the future potential of these platforms within closed-loop architectures is highlighted, paving the way for next-generation conductive hydrogel-based electrochemical sensors in smart healthcare applications.
- 20 February 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (2) , 267
Open AccessMXene- and MOF-Based Hydrogels: Emerging Platforms for Electrochemical Biosensing and Health Monitoring
Smart healthcare is rapidly emerging as a transformative paradigm, enabling simultaneous health monitoring, therapeutic intervention, and early prediction of disease onset. In this context, electrochemical monitoring systems have attracted growing interest due to their cost-effectiveness, ease of operation, miniaturization and compatibility with wearable platforms. Accordingly, conductive hydrogel-based electrochemical (bio)sensors have gained significant attention for health monitoring owing to their soft mechanical properties, high water content, excellent biocompatibility, and ability to form intimate, conformal interfaces with biological tissues. Their three-dimensional polymeric networks facilitate efficient ion transport and mechanical flexibility, making them particularly suitable for wearable and noninvasive sensing and monitoring applications. However, the intrinsically limited conductivity and catalytic activity of pristine hydrogels often constrain their electrochemical performance. To overcome these limitations, functional nanomaterials such as metal–organic frameworks (MOFs) and MXene (MX) nanosheets have been increasingly integrated into hydrogel matrices to enhance conductivity and electrochemical activity. This review provides a comprehensive and critical comparison of recent advances in MOF- and MX-integrated conductive hydrogels for electrochemical health monitoring. In addition to material design strategies and sensing performance, emerging trends in data-driven sensing aimed at improving signal interpretation and multi-analyte discrimination are systematically discussed. Key challenges related to long-term stability, biocompatibility, scalability, and intelligent system integration are critically assessed, and the future potential of these platforms within closed-loop architectures is highlighted, paving the way for next-generation conductive hydrogel-based electrochemical sensors in smart healthcare applications.
- Open Access
- 1 August 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (8) , 278
Biochar-Derived Electrochemical Sensors: A Green Route for Trace Heavy Metal Detection
The increasing demand for rapid, sensitive, and eco-friendly methods for the detection of trace heavy metals in environmental samples, attributed to their serious threats to health and the environment, has spurred considerable interest in the development of sustainable sensor materials. Toxic metal ions, namely, lead (Pb2+), cadmium (Cd2+), mercury (Hg2+), arsenic (As3+), and chromium, are potential hazards due to their non-biodegradable nature with high toxicity, even at trace levels. Acute health complications, including neurological, renal, and developmental disorders, arise upon exposure to such metal ions. To monitor and mitigate these toxic exposures, sensitive detection techniques are essential. Pre-existing conventional detection methods, such as atomic absorption spectroscopy (AAS) and inductively coupled plasma-mass spectrometry (ICP-MS), involve expensive instrumentation, skilled operators, and complex sample preparation. Electrochemical sensing, which is simple, portable, and eco-friendly, is foreseen as a potential alternative to the above conventional methods. Carbon-based nanomaterials play a crucial role in electrochemical sensors due to their high conductivity, stability, and the presence of surface functional groups. Biochar (BC), a carbon-rich product, has emerged as a promising electrode material for electrochemical sensing due to its high surface area, sustainability, tunable porosity, surface rich in functional groups, eco-friendliness, and negligible environmental footprint. Nevertheless, broad-spectrum studies on the use of biochar in electrochemical sensors remain narrow. This review focuses on the recent advancements in the development of biochar-based electrochemical sensors for the detection of toxic heavy metals such as Pb2+, Cd2+, and Hg2+ and the simultaneous detection of multiple ions, with special emphasis on BC synthesis routes, surface modification methodologies, electrode fabrication techniques, and electroanalytical performance. Finally, current challenges and future perspectives for integrating BC into next-generation sensor platforms are outlined.
- 1 August 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (8) , 278
Open AccessBiochar-Derived Electrochemical Sensors: A Green Route for Trace Heavy Metal Detection
The increasing demand for rapid, sensitive, and eco-friendly methods for the detection of trace heavy metals in environmental samples, attributed to their serious threats to health and the environment, has spurred considerable interest in the development of sustainable sensor materials. Toxic metal ions, namely, lead (Pb2+), cadmium (Cd2+), mercury (Hg2+), arsenic (As3+), and chromium, are potential hazards due to their non-biodegradable nature with high toxicity, even at trace levels. Acute health complications, including neurological, renal, and developmental disorders, arise upon exposure to such metal ions. To monitor and mitigate these toxic exposures, sensitive detection techniques are essential. Pre-existing conventional detection methods, such as atomic absorption spectroscopy (AAS) and inductively coupled plasma-mass spectrometry (ICP-MS), involve expensive instrumentation, skilled operators, and complex sample preparation. Electrochemical sensing, which is simple, portable, and eco-friendly, is foreseen as a potential alternative to the above conventional methods. Carbon-based nanomaterials play a crucial role in electrochemical sensors due to their high conductivity, stability, and the presence of surface functional groups. Biochar (BC), a carbon-rich product, has emerged as a promising electrode material for electrochemical sensing due to its high surface area, sustainability, tunable porosity, surface rich in functional groups, eco-friendliness, and negligible environmental footprint. Nevertheless, broad-spectrum studies on the use of biochar in electrochemical sensors remain narrow. This review focuses on the recent advancements in the development of biochar-based electrochemical sensors for the detection of toxic heavy metals such as Pb2+, Cd2+, and Hg2+ and the simultaneous detection of multiple ions, with special emphasis on BC synthesis routes, surface modification methodologies, electrode fabrication techniques, and electroanalytical performance. Finally, current challenges and future perspectives for integrating BC into next-generation sensor platforms are outlined.
- Open Access
- 20 March 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 12 (18) , 10819-10837
A (μ-oxo) dicopper complex anchoring graphitized mesoporous carbon surface prepared by an in situ electrochemical method for bioinspired electrocatalytic reduction of nitrite to ammonia and sensing
The design and development of functional biomimetic systems that resemble natural enzymes is highly challenging. Cytochrome c nitrite reductase (ccNiR), a specific enzyme containing multiple heme sites, functions as a catalyst for converting nitrite to ammonium through a complex six-electron transfer reaction under physiological conditions. In the literature, only a few homogeneous biomimetic metal complexes catalyzing nitrite reduction were reported, all under non-physiological conditions (organic and acid media). Herein, we developed a bioinspired copper(II)–BPA(μ-oxo) complex (BPA = bis(pyrid-2-ylmethyl)amine), denoted as {Cu2(μ-O)2}, immobilized on a graphitized mesoporous carbon modified glassy carbon electrode, GCE/GMC@{Cu2(μ-O)2}, which was prepared by an in situ electrochemical reaction of a precursor complex, {Cu(BPA)Cl}. The as-prepared GCE/GMC@{Cu2(μ-O)2} worked as an efficient biomimetic heterogeneous electrocatalyst for the reduction of nitrite into ammonia, in an aqueous medium and at neutral pH. This bioinspired system showed a stable and well-defined redox system with Eo′ = −220 mV vs. Ag/AgCl, and a surface-excess value of 83.9 nmol cm−2. The peak potential is much lower (>500 mV) than that of the unmodified electrode. In the presence of nitrite, a well-defined irreversible reduction peak at −0.250 V vs. Ag/AgCl is developed, which was assigned to the electrocatalytic reduction of nitrite. The molecular reaction and product formation were confirmed by SEM, TEM, Raman, IR, electrochemical quartz crystal microbalance (EQCM), and ESI-MS. A strong π–π interaction between the graphitic sp2 carbons and the aromatic sp2 in the BPA-pyridyl moiety of the metal complex favors good stability. To prove its functional application, the electroanalytical performance and bulk electrolysis conversion of nitrite into ammonia (faradaic efficiency of 92 ± 1%) were demonstrated.
- 20 March 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 12 (18) , 10819-10837
Open AccessA (μ-oxo) dicopper complex anchoring graphitized mesoporous carbon surface prepared by an in situ electrochemical method for bioinspired electrocatalytic reduction of nitrite to ammonia and sensing
The design and development of functional biomimetic systems that resemble natural enzymes is highly challenging. Cytochrome c nitrite reductase (ccNiR), a specific enzyme containing multiple heme sites, functions as a catalyst for converting nitrite to ammonium through a complex six-electron transfer reaction under physiological conditions. In the literature, only a few homogeneous biomimetic metal complexes catalyzing nitrite reduction were reported, all under non-physiological conditions (organic and acid media). Herein, we developed a bioinspired copper(II)–BPA(μ-oxo) complex (BPA = bis(pyrid-2-ylmethyl)amine), denoted as {Cu2(μ-O)2}, immobilized on a graphitized mesoporous carbon modified glassy carbon electrode, GCE/GMC@{Cu2(μ-O)2}, which was prepared by an in situ electrochemical reaction of a precursor complex, {Cu(BPA)Cl}. The as-prepared GCE/GMC@{Cu2(μ-O)2} worked as an efficient biomimetic heterogeneous electrocatalyst for the reduction of nitrite into ammonia, in an aqueous medium and at neutral pH. This bioinspired system showed a stable and well-defined redox system with Eo′ = −220 mV vs. Ag/AgCl, and a surface-excess value of 83.9 nmol cm−2. The peak potential is much lower (>500 mV) than that of the unmodified electrode. In the presence of nitrite, a well-defined irreversible reduction peak at −0.250 V vs. Ag/AgCl is developed, which was assigned to the electrocatalytic reduction of nitrite. The molecular reaction and product formation were confirmed by SEM, TEM, Raman, IR, electrochemical quartz crystal microbalance (EQCM), and ESI-MS. A strong π–π interaction between the graphitic sp2 carbons and the aromatic sp2 in the BPA-pyridyl moiety of the metal complex favors good stability. To prove its functional application, the electroanalytical performance and bulk electrolysis conversion of nitrite into ammonia (faradaic efficiency of 92 ± 1%) were demonstrated.
- 1 May 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (5) , 056507
In Situ Prussian Blue-Electrocatalyst Formation on Intrinsic Iron-Containing Pristine-MWCNT as a Template and Its EQCM and SECM Interrogations and Batch Injection Analysis of Hydrogen Peroxide
Herein, we report in-situ electrochemical derivatization of the intrinsic iron species in a pristine-multiwalled carbon nanotube (MWCNT) as Prussian blue (PB) modified MWCNT hybrid (MWCNT@PB) using a dilute solution of ferricyanide as a derivatization agent in pH 2 HCl-KCl solution. The PB hybrid system showed a defined redox peak at an apparent standard electrode potential, Eo’ = 0.18 V vs Ag/AgCl with an excess surface value, 1.71 × 10−10 mol cm−2. A discreet EQCM study on the electrochemical preparation of MWCNT@PB using MWCNT and ferricyanide precursors reveal the specific stripping of iron species and uptake of iron species, potassium and ferricyanide ions upon the electrochemical preparation condition. In-situ imaging of MWCNT@PB was carried out using SECM with ferricyanide as a redox mediator under a feedback-current mode. It has been identified that a mixed-potential based electrochemical reaction involving oxidative stripping of iron to iron ion species (step-1) coupled with reduction of ferricyanide to ferrocyanide (step-2) followed by a chemical interaction between the iron ion and ferricyanide (step-3) have occurred for the overall formation of MWCNT@PB hybrid. Electrocatalytic and electroanalytical performance of the MWCNT@PB hybrid towards H2O2 reduction and sensing were demonstrated by performing cyclic voltammetric, amperometric i-t and batch injection analysis.
- 1 May 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (5) , 056507
In Situ Prussian Blue-Electrocatalyst Formation on Intrinsic Iron-Containing Pristine-MWCNT as a Template and Its EQCM and SECM Interrogations and Batch Injection Analysis of Hydrogen Peroxide
Herein, we report in-situ electrochemical derivatization of the intrinsic iron species in a pristine-multiwalled carbon nanotube (MWCNT) as Prussian blue (PB) modified MWCNT hybrid (MWCNT@PB) using a dilute solution of ferricyanide as a derivatization agent in pH 2 HCl-KCl solution. The PB hybrid system showed a defined redox peak at an apparent standard electrode potential, Eo’ = 0.18 V vs Ag/AgCl with an excess surface value, 1.71 × 10−10 mol cm−2. A discreet EQCM study on the electrochemical preparation of MWCNT@PB using MWCNT and ferricyanide precursors reveal the specific stripping of iron species and uptake of iron species, potassium and ferricyanide ions upon the electrochemical preparation condition. In-situ imaging of MWCNT@PB was carried out using SECM with ferricyanide as a redox mediator under a feedback-current mode. It has been identified that a mixed-potential based electrochemical reaction involving oxidative stripping of iron to iron ion species (step-1) coupled with reduction of ferricyanide to ferrocyanide (step-2) followed by a chemical interaction between the iron ion and ferricyanide (step-3) have occurred for the overall formation of MWCNT@PB hybrid. Electrocatalytic and electroanalytical performance of the MWCNT@PB hybrid towards H2O2 reduction and sensing were demonstrated by performing cyclic voltammetric, amperometric i-t and batch injection analysis.
- 20 April 2023
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 127 (17) , 8016-8029
In Situ Electrochemical Trapping and Unraveling the Mechanism of the Toxic Intermediate Metabolite N-Acetyl-p-Benzoquinone Imine of the Acetaminophen Drug and Its Biomimetic Mediated NADH Oxidation Reaction
- 20 April 2023
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 127 (17) , 8016-8029
In Situ Electrochemical Trapping and Unraveling the Mechanism of the Toxic Intermediate Metabolite N-Acetyl-p-Benzoquinone Imine of the Acetaminophen Drug and Its Biomimetic Mediated NADH Oxidation Reaction
- 1 March 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (3) , 035501
In Situ Electro-organic Synthesis and Functionalization of Catechol Derivative on Carbon Black and Its Interference-free Voltammetric pH Sensor Application ∗
We report an easy electrochemical route for preparing a catechol derivative (di-ferulyl sesamol derivative, designated as CA-Fer) functionalized low-cost carbon black (CB) modified electrode in a neutral pH buffer solution. As synthesized precursor organic compound, CA-Fer has been electrochemically oxidized over the CB by potential cycling treatment in pH 7 PBS that leads to a high redox active CA-Fer-catechol derivative (CB@CA-Fer-Redox), which exhibited a well-defined and stable surface-confined redox response at Eo’ = 0.150 V vs Ag/AgCl with a surface excess value = 50.46 nmol cm−2. Unlike the conventional redox active mediators, GCE/CB@CA-Fer-Redox modified electrode has failed to show any mediated oxidation/reduction response to various electro-active biochemicals and chemicals, viz., ascorbic acid, glucose, cysteine, caffeic acid, hydrazine, hydrogen peroxide, uric acid, dopamine, creatinine, urea, nitrite, sulfide and sulfate ions, depicting a clear advantage of using it as a voltammetric pH sensor for real-time applications. The modified electrode showed a linear voltammetric potential signal against pH in a window, 3–11, with a slope value of (∂Ep/∂pH) = −59 ± 3 mV pH−1. As an independent study, a CA-Fer-Redox modified three-in-one screen printed electrode was developed, and a sensitive voltammetric pH analysis of some chemical biochemical real sample systems were demonstrated.
- 1 March 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (3) , 035501
In Situ Electro-organic Synthesis and Functionalization of Catechol Derivative on Carbon Black and Its Interference-free Voltammetric pH Sensor Application ∗
We report an easy electrochemical route for preparing a catechol derivative (di-ferulyl sesamol derivative, designated as CA-Fer) functionalized low-cost carbon black (CB) modified electrode in a neutral pH buffer solution. As synthesized precursor organic compound, CA-Fer has been electrochemically oxidized over the CB by potential cycling treatment in pH 7 PBS that leads to a high redox active CA-Fer-catechol derivative (CB@CA-Fer-Redox), which exhibited a well-defined and stable surface-confined redox response at Eo’ = 0.150 V vs Ag/AgCl with a surface excess value = 50.46 nmol cm−2. Unlike the conventional redox active mediators, GCE/CB@CA-Fer-Redox modified electrode has failed to show any mediated oxidation/reduction response to various electro-active biochemicals and chemicals, viz., ascorbic acid, glucose, cysteine, caffeic acid, hydrazine, hydrogen peroxide, uric acid, dopamine, creatinine, urea, nitrite, sulfide and sulfate ions, depicting a clear advantage of using it as a voltammetric pH sensor for real-time applications. The modified electrode showed a linear voltammetric potential signal against pH in a window, 3–11, with a slope value of (∂Ep/∂pH) = −59 ± 3 mV pH−1. As an independent study, a CA-Fer-Redox modified three-in-one screen printed electrode was developed, and a sensitive voltammetric pH analysis of some chemical biochemical real sample systems were demonstrated.
- 1 February 2022
- Published by Elsevier in Electrochimica Acta
- Vol. 405, 139806
In-situ scanning electrochemical microscopy interrogation on open-circuit release of toxic Ni2+ ion from Ni-containing carbon nanomaterials and nickel-hexacyanoferrate formation in physiological pH and its thiol-electrocatalysis relevance
- 1 February 2022
- Published by Elsevier in Electrochimica Acta
- Vol. 405, 139806
In-situ scanning electrochemical microscopy interrogation on open-circuit release of toxic Ni2+ ion from Ni-containing carbon nanomaterials and nickel-hexacyanoferrate formation in physiological pH and its thiol-electrocatalysis relevance