Ibrahim Ibrahim Shuaibu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ibrahim Ibrahim Shuaibu has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Anas Alkhamis
Near East University Faculty of Medicine, North Cyprus
3 shared publicationsDiyaa Alkhamis
Near East University Faculty of Medicine, North Cyprus
3 shared publicationsMuhammad Ayan Khan
Near East University Faculty of Medicine, North Cyprus
3 shared publications- Ahmad Nasr Harmouch
Beirut Arab University, Lebanon
2 shared publications - Yousaf Hussain
Near East University
2 shared publications Abdalsalam Rizq Abazid
Faculty of Medicine, Near East University, Nicosia, Cyprus
1 shared publication
Latest Publications
- Open Access
- 10 November 2026
- Published by Springer Nature
Road-segment risk of armed violence on Nigerian highways: a protocol v1
This protocol pre-specifies a study that estimates the risk of organised violence on Nigerian roads at the level of a 10 km road segment over a 7-day window, the scale at which a traveller decides whether to make a journey. Events come from the UCDP Georeferenced Event Dataset (GED) v26.1 and roads from OpenStreetMap; both can be redistributed, so the work is fully reproducible. A naive historical-rate baseline, penalised logistic regression and gradient-boosted trees are compared under strictly out-of-time validation, with calibration and decision-curve analysis reported alongside discrimination, because a traveller acts on the predicted number itself. A coded leakage check guards against predictors that see inside the window they predict. Version 1.0 was written on 7 November 2026 before any data were obtained; Amendment 1 (10 November 2026) records that this protocol is being registered after the first analysis was run, narrows the outcome to fatal organised violence, adds an ACLED sensitivity analysis, corrects the bootstrap to resample whole segments, and corrects a class-weighting defect.
- 10 November 2026
- Published by Springer Nature
Open AccessRoad-segment risk of armed violence on Nigerian highways: a protocol v1
This protocol pre-specifies a study that estimates the risk of organised violence on Nigerian roads at the level of a 10 km road segment over a 7-day window, the scale at which a traveller decides whether to make a journey. Events come from the UCDP Georeferenced Event Dataset (GED) v26.1 and roads from OpenStreetMap; both can be redistributed, so the work is fully reproducible. A naive historical-rate baseline, penalised logistic regression and gradient-boosted trees are compared under strictly out-of-time validation, with calibration and decision-curve analysis reported alongside discrimination, because a traveller acts on the predicted number itself. A coded leakage check guards against predictors that see inside the window they predict. Version 1.0 was written on 7 November 2026 before any data were obtained; Amendment 1 (10 November 2026) records that this protocol is being registered after the first analysis was run, narrows the outcome to fatal organised violence, adds an ACLED sensitivity analysis, corrects the bootstrap to resample whole segments, and corrects a class-weighting defect.
- Open Access
- 2 November 2026
- Published by Springer Nature in The Cardiothoracic Surgeon
- Vol. 34 (1) , 47
Deep learning versus conventional risk scores for postoperative mortality prediction in adult cardiac surgery: a systematic review
Background: Earlier reviews of machine learning for mortality after cardiac surgery pooled deep learning (DL) with shallow and non-neural methods. We asked whether models meeting an explicit definition of DL discriminate short-term mortality better than EuroSCORE II, the Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) or logistic regression in the same patients. Methods: This re-conducted review (PROSPERO CRD420261354546) supersedes an earlier preprint. MEDLINE, Europe PMC, Lens.org and IEEE Xplore were searched on 27–28 September 2026, with backward citation searching; Embase, CINAHL and CENTRAL were not searched, and forward citation searching was not performed. DL required at least two hidden layers, or a named architecture of established depth, shown in the source. A large language model pre-screened records and extracted data; two reviewers verified every decision and value. Risk of bias was assessed with PROBAST + AI, and results were synthesised without meta-analysis as within-cohort differences in the area under the curve (AUC). Results: Of 1,845 records identified, 515 duplicates were removed and 1,330 were screened; of 76 reports sought, 54 were assessed in full and 22 could not be retrieved. Four studies (five cohort-level comparisons) met all criteria. A chest-radiograph convolutional network had lower AUCs than STS-PROM in temporal (0.829 vs. 0.884) and external (0.738 vs. 0.803) cohorts with about two dozen deaths each; two-hidden-layer perceptrons did not outperform logistic regression (0.761 vs. 0.762; 0.77 vs. 0.80); one study reported AUCs only graphically. All four studies had high or unclear risk of bias. Fifteen reports described networks of undetermined depth, including a tabular transformer that outperformed EuroSCORE II internally (0.834 vs. 0.807); in the 12 with extractable comparisons, the network had a higher AUC than the best comparator in 4 and lower in 8 (median difference − 0.004). Conclusions: Evidence that DL improves on established scores for short-term mortality after adult cardiac surgery is sparse, inconsistent and at high or unclear risk of bias, and the search was incomplete relative to the registered protocol. Differences in discrimination were small or absent, and calibration and clinical utility were rarely evaluated. Superiority cannot be established. PROSPERO registration: This review was registered on PROSPERO, the International Prospective Register of Systematic Reviews, on 29 March 2026 (CRD420261354546; https://www.crd.york.ac.uk/prospero/). At registration, the record stated that searching and screening for an earlier version of the review had been completed and that data extraction had not started. That earlier version was posted as a preprint on 31 March 2026 (Preprints.org, doi:10.20944/preprints202603.2465.v1); it is superseded by this report. Its withdrawal was requested from Preprints.org on 18 October 2026 and had not been confirmed at the time of resubmission. The review reported here was re-conducted in full after registration: the searches were run on 27–28 September 2026, and screening, data extraction and risk-of-bias assessment followed. The registered eligibility criteria were not changed in substance; the registered deep-learning criterion was operationalised before full-text assessment and, after peer review, applied more strictly (a post hoc change reported in the manuscript). The search sources, risk-of-bias tool and synthesis method differ from the registered protocol. Every difference, with its timing and reason, is reported in Table 1 of the manuscript, and an amendment describing them has been submitted to PROSPERO.
- 2 November 2026
- Published by Springer Nature in The Cardiothoracic Surgeon
- Vol. 34 (1) , 47
Open AccessDeep learning versus conventional risk scores for postoperative mortality prediction in adult cardiac surgery: a systematic review
Background: Earlier reviews of machine learning for mortality after cardiac surgery pooled deep learning (DL) with shallow and non-neural methods. We asked whether models meeting an explicit definition of DL discriminate short-term mortality better than EuroSCORE II, the Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) or logistic regression in the same patients. Methods: This re-conducted review (PROSPERO CRD420261354546) supersedes an earlier preprint. MEDLINE, Europe PMC, Lens.org and IEEE Xplore were searched on 27–28 September 2026, with backward citation searching; Embase, CINAHL and CENTRAL were not searched, and forward citation searching was not performed. DL required at least two hidden layers, or a named architecture of established depth, shown in the source. A large language model pre-screened records and extracted data; two reviewers verified every decision and value. Risk of bias was assessed with PROBAST + AI, and results were synthesised without meta-analysis as within-cohort differences in the area under the curve (AUC). Results: Of 1,845 records identified, 515 duplicates were removed and 1,330 were screened; of 76 reports sought, 54 were assessed in full and 22 could not be retrieved. Four studies (five cohort-level comparisons) met all criteria. A chest-radiograph convolutional network had lower AUCs than STS-PROM in temporal (0.829 vs. 0.884) and external (0.738 vs. 0.803) cohorts with about two dozen deaths each; two-hidden-layer perceptrons did not outperform logistic regression (0.761 vs. 0.762; 0.77 vs. 0.80); one study reported AUCs only graphically. All four studies had high or unclear risk of bias. Fifteen reports described networks of undetermined depth, including a tabular transformer that outperformed EuroSCORE II internally (0.834 vs. 0.807); in the 12 with extractable comparisons, the network had a higher AUC than the best comparator in 4 and lower in 8 (median difference − 0.004). Conclusions: Evidence that DL improves on established scores for short-term mortality after adult cardiac surgery is sparse, inconsistent and at high or unclear risk of bias, and the search was incomplete relative to the registered protocol. Differences in discrimination were small or absent, and calibration and clinical utility were rarely evaluated. Superiority cannot be established. PROSPERO registration: This review was registered on PROSPERO, the International Prospective Register of Systematic Reviews, on 29 March 2026 (CRD420261354546; https://www.crd.york.ac.uk/prospero/). At registration, the record stated that searching and screening for an earlier version of the review had been completed and that data extraction had not started. That earlier version was posted as a preprint on 31 March 2026 (Preprints.org, doi:10.20944/preprints202603.2465.v1); it is superseded by this report. Its withdrawal was requested from Preprints.org on 18 October 2026 and had not been confirmed at the time of resubmission. The review reported here was re-conducted in full after registration: the searches were run on 27–28 September 2026, and screening, data extraction and risk-of-bias assessment followed. The registered eligibility criteria were not changed in substance; the registered deep-learning criterion was operationalised before full-text assessment and, after peer review, applied more strictly (a post hoc change reported in the manuscript). The search sources, risk-of-bias tool and synthesis method differ from the registered protocol. Every difference, with its timing and reason, is reported in Table 1 of the manuscript, and an amendment describing them has been submitted to PROSPERO.
- Open Access
- 1 October 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Two barriers to benchmarking structure-based virtual screening against the AcrB efflux pump: a sample-size ceiling and an identifiability failure
Background. The AcrAB-TolC system is the principal constitutive efflux pump of Escherichia coli and an attractive adjuvant target. Virtual screening campaigns against its distal binding pocket have been published without the retrospective validation standard elsewhere in the field. This study asked whether such a benchmark can be built from the published literature. Methods. Compounds reported as AcrB inhibitors were filtered against an independent reproducibility screen and assigned to a binding site by the strongest structural or mutational evidence available. Property-matched decoys, a library-representative background and a class of reported-but-non-reproducing inhibitors served as negatives. A pilot docking screen against the hydrophobic trap of 5ENQ was re-analysed under the curated labels, with areas under the receiver-operating-characteristic curve reported with analytic and bootstrap confidence intervals. Two controls were pre-specified: a wrong-site control, and a ligand-only ablation deleting the receptor entirely. Results. Of 49 compounds reported as AcrB inhibitors, 38 have been independently retested and 17 reproduced; 13 maps to the distal pocket and 5 have a co-crystal there. Two barriers follow. With 5 actives the 95% interval cannot be narrower than ±0.26; reaching a conventional ±0.06 would require 94 actives, while raising the decoy ratio from 40:1 to 500:1 narrows the interval by 0.8%. More seriously, the ligand-only ablation reached 1.000 against a docking area of 0.707: deleting the receptor improved performance. 4 of the 5 co-crystal actives are analogues spanning 2 scaffolds, with a median pairwise ECFP4 similarity of 0.574 against 0.077 to the negatives; every active–active pair lies above the decoy-exclusion threshold of 0.35 and every active–negative pair below it. Conclusions. A retrospective docking benchmark for the AcrB distal pocket cannot currently be built. The first barrier is quantitative and yields to more confirmed inhibitors of any kind; the second is qualitative and yields only to inhibitors that are chemically unlike one another. Screening against this pocket therefore proceeds unvalidated and cannot be validated until structurally diverse confirmed inhibitors exist, which is a medicinal-chemistry result rather than a computational one. The curated compound table, the metrics implementation with its unit tests and the analysis notebook are released.
- 1 October 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessTwo barriers to benchmarking structure-based virtual screening against the AcrB efflux pump: a sample-size ceiling and an identifiability failure
Background. The AcrAB-TolC system is the principal constitutive efflux pump of Escherichia coli and an attractive adjuvant target. Virtual screening campaigns against its distal binding pocket have been published without the retrospective validation standard elsewhere in the field. This study asked whether such a benchmark can be built from the published literature. Methods. Compounds reported as AcrB inhibitors were filtered against an independent reproducibility screen and assigned to a binding site by the strongest structural or mutational evidence available. Property-matched decoys, a library-representative background and a class of reported-but-non-reproducing inhibitors served as negatives. A pilot docking screen against the hydrophobic trap of 5ENQ was re-analysed under the curated labels, with areas under the receiver-operating-characteristic curve reported with analytic and bootstrap confidence intervals. Two controls were pre-specified: a wrong-site control, and a ligand-only ablation deleting the receptor entirely. Results. Of 49 compounds reported as AcrB inhibitors, 38 have been independently retested and 17 reproduced; 13 maps to the distal pocket and 5 have a co-crystal there. Two barriers follow. With 5 actives the 95% interval cannot be narrower than ±0.26; reaching a conventional ±0.06 would require 94 actives, while raising the decoy ratio from 40:1 to 500:1 narrows the interval by 0.8%. More seriously, the ligand-only ablation reached 1.000 against a docking area of 0.707: deleting the receptor improved performance. 4 of the 5 co-crystal actives are analogues spanning 2 scaffolds, with a median pairwise ECFP4 similarity of 0.574 against 0.077 to the negatives; every active–active pair lies above the decoy-exclusion threshold of 0.35 and every active–negative pair below it. Conclusions. A retrospective docking benchmark for the AcrB distal pocket cannot currently be built. The first barrier is quantitative and yields to more confirmed inhibitors of any kind; the second is qualitative and yields only to inhibitors that are chemically unlike one another. Screening against this pocket therefore proceeds unvalidated and cannot be validated until structurally diverse confirmed inhibitors exist, which is a medicinal-chemistry result rather than a computational one. The curated compound table, the metrics implementation with its unit tests and the analysis notebook are released.
- Open Access
- 23 September 2026
- Published by MDPI AG in Preprints.org
Stereochemical Redundancy Inflates Benchmark Performance of Two-Dimensional Molecular Representations in Blood-Brain Barrier Permeability Prediction
Background: Machine learning models for blood-brain barrier (BBB) permeability are routinely benchmarked on the B3DB dataset, with reported areas under the receiver operating characteristic curve (ROC-AUC) frequently exceeding 0.90. Scaffold-based data splitting is widely regarded as sufficient protection against optimistic bias. We hypothesised that this protection is incomplete, because the two-dimensional (2D) molecular representations in general use cannot distinguish stereoisomers, which therefore remain effectively duplicated across scaffold-disjoint partitions. Methods: B3DB (7,807 records) was curated under two strategies: conventional deduplication on canonical SMILES and deduplication on the InChIKey skeleton, which collapses stereoisomers, tautomers, and protonation variants. Under each curation we evaluated five models, a physicochemical-descriptor logistic regression baseline, ECFP4 random forest, ECFP4 XGBoost, ECFP4 LightGBM, and a combined ECFP4-plus-descriptor LightGBM, across 20 independent randomized Bemis-Murcko scaffold splits. Probability calibration and classification thresholds were derived exclusively from validation partitions. Uncertainty was quantified by bootstrap and paired across-split comparison. An applicability domain analysis stratified test compounds by maximum Tanimoto similarity to training chemistry. A dedicated experiment assessed whether chirality-aware fingerprints could resolve skeletons carrying discordant labels. Results: Canonical-SMILES deduplication identified only 3 duplicate structures. Skeleton-level deduplication identified 1,490 duplicated skeletons, reducing the dataset from 7,802 to 3,952 compounds, and revealed 131 skeletons carrying discordant BBB+/BBB− labels. Apparent performance fell substantially under skeleton-collapsed curation: ECFP4 random forest from ROC-AUC 0.938 ± 0.025 to 0.871 ± 0.033, and the descriptor baseline from 0.851 ± 0.021 to 0.782 ± 0.030. The inflation was therefore comparable for fingerprint and descriptor representations (0.062 to 0.070 and 0.069 ROC-AUC, respectively), indicating a representation-general rather than fingerprint-specific artifact. The advantage of fingerprints over physicochemical descriptors was robust to curation (paired ΔROC-AUC 0.091, 95% CI 0.065 to 0.119 and 0.093 ± 0.033, favoring fingerprints in 20 of 20 splits). Performance depended steeply on chemical proximity to training data, with ROC-AUC rising from 0.723 for compounds lacking any close training analogue to 0.935 for those with one. All 131 discordant skeletons were genuine stereoisomer pairs; although 126 (96.2%) were distinguishable by chirality-aware fingerprints, such fingerprints ordered discordant pairs correctly in only 66 of 131 cases (50.4%, chance level). Conclusions: Skeleton-level redundancy in B3DB inflates benchmark performance of all common 2D representations by approximately 0.07 ROC-AUC, and scaffold splitting does not prevent this because stereoisomers share a scaffold-independent identity. We recommend skeleton-level deduplication as a mandatory curation step and routine reporting of applicability-domain-stratified performance. Stereochemically determined label conflicts are real and irreducible for 2D methods, placing an intrinsic ceiling on achievable accuracy.
- 23 September 2026
- Published by MDPI AG in Preprints.org
Open AccessStereochemical Redundancy Inflates Benchmark Performance of Two-Dimensional Molecular Representations in Blood-Brain Barrier Permeability Prediction
Background: Machine learning models for blood-brain barrier (BBB) permeability are routinely benchmarked on the B3DB dataset, with reported areas under the receiver operating characteristic curve (ROC-AUC) frequently exceeding 0.90. Scaffold-based data splitting is widely regarded as sufficient protection against optimistic bias. We hypothesised that this protection is incomplete, because the two-dimensional (2D) molecular representations in general use cannot distinguish stereoisomers, which therefore remain effectively duplicated across scaffold-disjoint partitions. Methods: B3DB (7,807 records) was curated under two strategies: conventional deduplication on canonical SMILES and deduplication on the InChIKey skeleton, which collapses stereoisomers, tautomers, and protonation variants. Under each curation we evaluated five models, a physicochemical-descriptor logistic regression baseline, ECFP4 random forest, ECFP4 XGBoost, ECFP4 LightGBM, and a combined ECFP4-plus-descriptor LightGBM, across 20 independent randomized Bemis-Murcko scaffold splits. Probability calibration and classification thresholds were derived exclusively from validation partitions. Uncertainty was quantified by bootstrap and paired across-split comparison. An applicability domain analysis stratified test compounds by maximum Tanimoto similarity to training chemistry. A dedicated experiment assessed whether chirality-aware fingerprints could resolve skeletons carrying discordant labels. Results: Canonical-SMILES deduplication identified only 3 duplicate structures. Skeleton-level deduplication identified 1,490 duplicated skeletons, reducing the dataset from 7,802 to 3,952 compounds, and revealed 131 skeletons carrying discordant BBB+/BBB− labels. Apparent performance fell substantially under skeleton-collapsed curation: ECFP4 random forest from ROC-AUC 0.938 ± 0.025 to 0.871 ± 0.033, and the descriptor baseline from 0.851 ± 0.021 to 0.782 ± 0.030. The inflation was therefore comparable for fingerprint and descriptor representations (0.062 to 0.070 and 0.069 ROC-AUC, respectively), indicating a representation-general rather than fingerprint-specific artifact. The advantage of fingerprints over physicochemical descriptors was robust to curation (paired ΔROC-AUC 0.091, 95% CI 0.065 to 0.119 and 0.093 ± 0.033, favoring fingerprints in 20 of 20 splits). Performance depended steeply on chemical proximity to training data, with ROC-AUC rising from 0.723 for compounds lacking any close training analogue to 0.935 for those with one. All 131 discordant skeletons were genuine stereoisomer pairs; although 126 (96.2%) were distinguishable by chirality-aware fingerprints, such fingerprints ordered discordant pairs correctly in only 66 of 131 cases (50.4%, chance level). Conclusions: Skeleton-level redundancy in B3DB inflates benchmark performance of all common 2D representations by approximately 0.07 ROC-AUC, and scaffold splitting does not prevent this because stereoisomers share a scaffold-independent identity. We recommend skeleton-level deduplication as a mandatory curation step and routine reporting of applicability-domain-stratified performance. Stereochemically determined label conflicts are real and irreducible for 2D methods, placing an intrinsic ceiling on achievable accuracy.
- Open Access
- 5 August 2026
- Published by Springer Nature in BMC Neurology
- Vol. 26 (1)
Mitochondrial Haplogroup U and multiple sclerosis risk in Arab and Near Eastern populations: a systematic review and meta-analysis
- 5 August 2026
- Published by Springer Nature in BMC Neurology
- Vol. 26 (1)
Open AccessMitochondrial Haplogroup U and multiple sclerosis risk in Arab and Near Eastern populations: a systematic review and meta-analysis
- Open Access
- 6 July 2026
- Published by MDPI AG in Preprints.org
Metadata Insufficiency and Reporting Deficits in Medical AI Generalization: A Meta-Research Audit Using Non-Parametric Bootstrap Resampling
Background: External validation performance drops are routinely reported in medical artificial intelligence (AI) literature, yet the study-level metadata features that systematically predict this degradation remain poorly characterised. Existing systematic reviews have catalogued performance metrics without subjecting the explanatory value of reported metadata to rigorous empirical audit. Objective: To quantify the explanatory ceiling of progressively richer metadata tiers on observed AUC degradation at external validation, and to identify which specific features carry replicable predictive signal across 1,000 non-parametric bootstrap resamples. Methods: A systematic search of PubMed/MEDLINE (January 2016 – May 2026), supplemented by Scopus and IEEE Xplore, identified 100 peer-reviewed studies reporting both internal performance and quantitative external validation outcomes for medical imaging AI. Thirteen metadata features were extracted and organised into four progressive complexity tiers. Explanatory power was assessed by the 10-fold cross-validated R² metric from a random-forest regression fitted on each tier. Replicable feature-selection frequency was estimated by 1,000 non-parametric bootstrap resamples with a 5% alpha threshold. Modality-stratified sensitivity analyses were conducted across three clinical imaging domains: ophthalmology (fundus photography), chest radiography, and computed tomography. Results: The full 13-feature model explained only −60.5% of variance in AUC degradation (10-fold cross-validated R² = −0.6053), with the deficit deepening monotonically across all four metadata tiers (Tier 1: R² = −0.3438; Tier 2: −0.4002; Tier 3: −0.5025). Non-parametric bootstrap resampling identified augmentation_applied as the single feature with selection frequency exceeding the 5% alpha threshold (frequency ≈65%), followed by class_balance_ratio (~23%) and architecture_type (~15%). All other features remained below threshold. Modality sensitivity profiles were broadly comparable across the three imaging domains, though CT studies exhibited the widest range of observed performance drops (ΔAUC range: −0.05 to +0.21). Conclusions: Collectively reported metadata—including dataset size, architecture, and AUC—leaves the overwhelming majority of observed generalisation variance unexplained. The consistent explanatory deficit across all metadata tiers signals a structural reporting gap rather than a predictive modelling limitation. Augmentation strategy, class-balance handling, and architecture type constitute the minimum replicable predictive signal currently available. Standardised metadata reporting frameworks, covering training data provenance, preprocessing pipelines, and demographic covariates, are required before comparative generalisation benchmarks can be meaningfully established.
- 6 July 2026
- Published by MDPI AG in Preprints.org
Open AccessMetadata Insufficiency and Reporting Deficits in Medical AI Generalization: A Meta-Research Audit Using Non-Parametric Bootstrap Resampling
Background: External validation performance drops are routinely reported in medical artificial intelligence (AI) literature, yet the study-level metadata features that systematically predict this degradation remain poorly characterised. Existing systematic reviews have catalogued performance metrics without subjecting the explanatory value of reported metadata to rigorous empirical audit. Objective: To quantify the explanatory ceiling of progressively richer metadata tiers on observed AUC degradation at external validation, and to identify which specific features carry replicable predictive signal across 1,000 non-parametric bootstrap resamples. Methods: A systematic search of PubMed/MEDLINE (January 2016 – May 2026), supplemented by Scopus and IEEE Xplore, identified 100 peer-reviewed studies reporting both internal performance and quantitative external validation outcomes for medical imaging AI. Thirteen metadata features were extracted and organised into four progressive complexity tiers. Explanatory power was assessed by the 10-fold cross-validated R² metric from a random-forest regression fitted on each tier. Replicable feature-selection frequency was estimated by 1,000 non-parametric bootstrap resamples with a 5% alpha threshold. Modality-stratified sensitivity analyses were conducted across three clinical imaging domains: ophthalmology (fundus photography), chest radiography, and computed tomography. Results: The full 13-feature model explained only −60.5% of variance in AUC degradation (10-fold cross-validated R² = −0.6053), with the deficit deepening monotonically across all four metadata tiers (Tier 1: R² = −0.3438; Tier 2: −0.4002; Tier 3: −0.5025). Non-parametric bootstrap resampling identified augmentation_applied as the single feature with selection frequency exceeding the 5% alpha threshold (frequency ≈65%), followed by class_balance_ratio (~23%) and architecture_type (~15%). All other features remained below threshold. Modality sensitivity profiles were broadly comparable across the three imaging domains, though CT studies exhibited the widest range of observed performance drops (ΔAUC range: −0.05 to +0.21). Conclusions: Collectively reported metadata—including dataset size, architecture, and AUC—leaves the overwhelming majority of observed generalisation variance unexplained. The consistent explanatory deficit across all metadata tiers signals a structural reporting gap rather than a predictive modelling limitation. Augmentation strategy, class-balance handling, and architecture type constitute the minimum replicable predictive signal currently available. Standardised metadata reporting frameworks, covering training data provenance, preprocessing pipelines, and demographic covariates, are required before comparative generalisation benchmarks can be meaningfully established.
- Open Access
- 31 March 2026
- Published by MDPI AG in Preprints.org
Evaluating the Predictive Accuracy of Deep Learning Algorithms for Postoperative Mortality in Cardiac Surgery: A Systematic Review and Meta-Analysis
Background: Risk stratification in cardiac surgery has long depended on logistic regression models built from a fixed set of preoperative variables an approach that, while extensively validated, cannot capture the complexity of real patient physiology. Deep learning (DL) offers a fundamentally different paradigm, one capable of detecting non-linear interactions across high-dimensional datasets. We conducted this systematic review and meta-analysis to quantify whether that theoretical advantage translates into measurably better prediction of postoperative mortality after cardiac SurgeryMethods: We searched PubMed/MEDLINE, Embase, and IEEE Xplore following PRISMA 2020 and Cochrane Prognosis Methods Group guidelines. Eligible studies directly compared DL architectures against established risk scores namely EuroSCORE II or STS-PROM for short-term mortality in adult cardiac surgery populations. Methodological quality was assessed with PROBAST+AI. Because raw AUC values are bounded and violate normality assumptions required for standard pooling, all estimates were logit-transformed prior to meta-analysis using a restricted maximum likelihood random-effects model.Results: Six studies met inclusion criteria, representing 250,560 patients across markedly different clinical settings. Deep learning models shows to have achieved a pooled AUC of 0.856 (95% CI: 0.774 - 0.913). This came with a caveat: between-study heterogeneity was substantial (I² = 91.3%), reflecting the diversity of architectures, cohort sizes, and institutional contexts included. Traditional risk scores yielded a pooled AUC of 0.815 (95% CI: 0.754–0.864; I² = 77.9%).Conclusion: DL models outperform conventional risk scores on discrimination. The gap, however, sits alongside serious unresolved questions heterogeneity is high, calibration data are largely absent from the primary literature, and most evidence comes from retrospective single-centre cohorts. Standardized reporting frameworks are a prerequisite, not a recommendation, before these models enter routine clinical practice.
- 31 March 2026
- Published by MDPI AG in Preprints.org
Open AccessEvaluating the Predictive Accuracy of Deep Learning Algorithms for Postoperative Mortality in Cardiac Surgery: A Systematic Review and Meta-Analysis
Background: Risk stratification in cardiac surgery has long depended on logistic regression models built from a fixed set of preoperative variables an approach that, while extensively validated, cannot capture the complexity of real patient physiology. Deep learning (DL) offers a fundamentally different paradigm, one capable of detecting non-linear interactions across high-dimensional datasets. We conducted this systematic review and meta-analysis to quantify whether that theoretical advantage translates into measurably better prediction of postoperative mortality after cardiac SurgeryMethods: We searched PubMed/MEDLINE, Embase, and IEEE Xplore following PRISMA 2020 and Cochrane Prognosis Methods Group guidelines. Eligible studies directly compared DL architectures against established risk scores namely EuroSCORE II or STS-PROM for short-term mortality in adult cardiac surgery populations. Methodological quality was assessed with PROBAST+AI. Because raw AUC values are bounded and violate normality assumptions required for standard pooling, all estimates were logit-transformed prior to meta-analysis using a restricted maximum likelihood random-effects model.Results: Six studies met inclusion criteria, representing 250,560 patients across markedly different clinical settings. Deep learning models shows to have achieved a pooled AUC of 0.856 (95% CI: 0.774 - 0.913). This came with a caveat: between-study heterogeneity was substantial (I² = 91.3%), reflecting the diversity of architectures, cohort sizes, and institutional contexts included. Traditional risk scores yielded a pooled AUC of 0.815 (95% CI: 0.754–0.864; I² = 77.9%).Conclusion: DL models outperform conventional risk scores on discrimination. The gap, however, sits alongside serious unresolved questions heterogeneity is high, calibration data are largely absent from the primary literature, and most evidence comes from retrospective single-centre cohorts. Standardized reporting frameworks are a prerequisite, not a recommendation, before these models enter routine clinical practice.
- Open Access
- 3 February 2026
- Published by Springer Nature in Research Square
Early Vasopressor Initiation versus Standard Fluid Resuscitation in Normotensive Cryptic Shock: A Target Trial Emulation
Background Current sepsis guidelines mandate aggressive fluid resuscitation prior to vasopressor initiation, primarily targeting hypotension (Mean Arterial Pressure [MAP] < 65 mmHg). However, a distinct phenotype of "Cryptic Shock" characterized by severe tissue hypoperfusion (Lactate > 4.0 mmol/L) despite preserved normotension (MAP > 65 mmHg) remains poorly managed. We hypothesized that early initiation of vasopressors, rather than fluid-centric resuscitation, would improve survival in this high-risk phenotype. Methods We performed a Target Trial Emulation using the MIMIC-IV v3.1 database (2008–2019). We identified adult patients meeting criteria for Cryptic Shock within 24 hours of ICU admission. Patients were classified into two treatment strategies based on interventions received within the first 3 hours of phenotype onset: (1) Early Vasopressors (initiation of norepinephrine or vasopressin) versus (2) Standard Care (fluid resuscitation alone). The primary endpoint was 28-day mortality. To adjust for confounding by indication, we employed Inverse Probability of Treatment Weighting (IPTW) based on age, SOFA score, and admission lactate. Survival was analyzed using weighted Kaplan-Meier curves and multivariable Cox proportional hazards models. Results The final cohort comprised 3,558 patients. The Early Vasopressor group (n = 1,245) had significantly higher baseline severity scores (SOFA 9.0 vs. 6.0) compared to the Standard Care group (n = 2,313). After IPTW adjustment, covariate balance was achieved (Standardized Mean Difference < 0.1 for all variables). Early vasopressor initiation was associated with a significant reduction in 28-day mortality compared to standard care (Adjusted Hazard Ratio [HR] 0.48; 95% CI, 0.40–0.58; p < 0.001). This survival benefit persisted across sensitivity analyses. Conclusions In patients with Cryptic Shock, an early vasopressor strategy is associated with superior 28-day survival compared to standard fluid resuscitation. These findings challenge the "fluids-first" paradigm for normotensive hypoperfusion and support a shift toward perfusion-guided resuscitation.
- 3 February 2026
- Published by Springer Nature in Research Square
Open AccessEarly Vasopressor Initiation versus Standard Fluid Resuscitation in Normotensive Cryptic Shock: A Target Trial Emulation
Background Current sepsis guidelines mandate aggressive fluid resuscitation prior to vasopressor initiation, primarily targeting hypotension (Mean Arterial Pressure [MAP] < 65 mmHg). However, a distinct phenotype of "Cryptic Shock" characterized by severe tissue hypoperfusion (Lactate > 4.0 mmol/L) despite preserved normotension (MAP > 65 mmHg) remains poorly managed. We hypothesized that early initiation of vasopressors, rather than fluid-centric resuscitation, would improve survival in this high-risk phenotype. Methods We performed a Target Trial Emulation using the MIMIC-IV v3.1 database (2008–2019). We identified adult patients meeting criteria for Cryptic Shock within 24 hours of ICU admission. Patients were classified into two treatment strategies based on interventions received within the first 3 hours of phenotype onset: (1) Early Vasopressors (initiation of norepinephrine or vasopressin) versus (2) Standard Care (fluid resuscitation alone). The primary endpoint was 28-day mortality. To adjust for confounding by indication, we employed Inverse Probability of Treatment Weighting (IPTW) based on age, SOFA score, and admission lactate. Survival was analyzed using weighted Kaplan-Meier curves and multivariable Cox proportional hazards models. Results The final cohort comprised 3,558 patients. The Early Vasopressor group (n = 1,245) had significantly higher baseline severity scores (SOFA 9.0 vs. 6.0) compared to the Standard Care group (n = 2,313). After IPTW adjustment, covariate balance was achieved (Standardized Mean Difference < 0.1 for all variables). Early vasopressor initiation was associated with a significant reduction in 28-day mortality compared to standard care (Adjusted Hazard Ratio [HR] 0.48; 95% CI, 0.40–0.58; p < 0.001). This survival benefit persisted across sensitivity analyses. Conclusions In patients with Cryptic Shock, an early vasopressor strategy is associated with superior 28-day survival compared to standard fluid resuscitation. These findings challenge the "fluids-first" paradigm for normotensive hypoperfusion and support a shift toward perfusion-guided resuscitation.
- Open Access
- 23 January 2026
- Published by MDPI AG in Preprints.org
Beyond Static Thresholds: Oscillatory Hemodynamic Instability as a Prodromal Marker for Intraoperative Hypotension Using Explainable Machine Learning
Background: Intraoperative hypotension (IOH) is strongly associated with postoperative myocardial injury, acute kidney injury, and mortality. Current monitoring relies on reactive threshold alarms, often alerting clinicians only after hemodynamic compromise has occurred. We hypothesized that a machine learning (ML) approach utilizing engineered hemodynamic volatility features could predict IOH five minutes before its occurrence. Methods: A retrospective observational study was conducted using high-resolution intraoperative monitoring data from the VitalDB registry. The cohort included 1,750 adult patients undergoing non-cardiac surgery. We developed and compared three ML algorithms Logistic Regression (LR), Random Forest (RF), and Extreme Gradient Boosting (XGBoost) trained on physiological features including arterial pressure trends and rolling volatility indices. Performance was evaluated using the Area Under the Receiver Operating Characteristic Curve (AUROC) for discrimination and the Brier Score for calibration. Results: All models demonstrated robust predictive capability. The Random Forest model achieved the highest discrimination (AUROC 0.837), outperforming LR (0.824) and XGBoost (0.803). However, XGBoost demonstrated superior calibration with a Brier Score of 0.0825 (vs. 0.153 for RF), indicating more reliable probabilistic risk estimates. Feature importance analysis consistently identified hemodynamic volatility (rolling standard deviation of MAP) as the dominant predictor across all models. At the optimal threshold, the system demonstrated a sensitivity of 69.5% and specificity of 75.3%. Conclusions: We identified a trade-off between discrimination and calibration: Random Forest offers the best ranking for early warning, while XGBoost provides the most accurate risk probability. Crucially, hemodynamic instability was identified as a critical prodromal marker, suggesting that oscillatory variance precedes hypotension.
- 23 January 2026
- Published by MDPI AG in Preprints.org
Open AccessBeyond Static Thresholds: Oscillatory Hemodynamic Instability as a Prodromal Marker for Intraoperative Hypotension Using Explainable Machine Learning
Background: Intraoperative hypotension (IOH) is strongly associated with postoperative myocardial injury, acute kidney injury, and mortality. Current monitoring relies on reactive threshold alarms, often alerting clinicians only after hemodynamic compromise has occurred. We hypothesized that a machine learning (ML) approach utilizing engineered hemodynamic volatility features could predict IOH five minutes before its occurrence. Methods: A retrospective observational study was conducted using high-resolution intraoperative monitoring data from the VitalDB registry. The cohort included 1,750 adult patients undergoing non-cardiac surgery. We developed and compared three ML algorithms Logistic Regression (LR), Random Forest (RF), and Extreme Gradient Boosting (XGBoost) trained on physiological features including arterial pressure trends and rolling volatility indices. Performance was evaluated using the Area Under the Receiver Operating Characteristic Curve (AUROC) for discrimination and the Brier Score for calibration. Results: All models demonstrated robust predictive capability. The Random Forest model achieved the highest discrimination (AUROC 0.837), outperforming LR (0.824) and XGBoost (0.803). However, XGBoost demonstrated superior calibration with a Brier Score of 0.0825 (vs. 0.153 for RF), indicating more reliable probabilistic risk estimates. Feature importance analysis consistently identified hemodynamic volatility (rolling standard deviation of MAP) as the dominant predictor across all models. At the optimal threshold, the system demonstrated a sensitivity of 69.5% and specificity of 75.3%. Conclusions: We identified a trade-off between discrimination and calibration: Random Forest offers the best ranking for early warning, while XGBoost provides the most accurate risk probability. Crucially, hemodynamic instability was identified as a critical prodromal marker, suggesting that oscillatory variance precedes hypotension.
- Open Access
- 22 January 2026
- Published by MDPI AG in Preprints.org
Benchmarking Ensemble Machine Learning Algorithms for the Early Prediction of Stroke in Imbalanced Clinical Cohorts: A Comparative Analysis and Decision Curve Assessment
Background: Stroke remains a leading cause of mortality and long-term disability globally, necessitating effective primary prevention strategies. While machine learning (ML) models offer superior predictive capabilities compared to traditional linear risk scores, their application in clinical practice is often hindered by the "class imbalance" problem, where the rarity of stroke events leads to biased, low-sensitivity models. Furthermore, the literature currently lacks rigorous head-to-head benchmarking of modern boosting algorithms on moderate-sized clinical datasets. This study aimed to identify the optimal predictive model for stroke by systematically benchmarking seven ensemble algorithms and validating their clinical utility using Decision Curve Analysis (DCA).Methods: We analyzed a retrospective multi-center cohort of 5,110 patients, characterized by a severe class imbalance (4.9% stroke incidence). Feature engineering included the encoding of sociodemographic determinants and clinical biomarkers. We conducted a rigorous 10-fold stratified cross-validation tournament to compare seven classifiers: Linear Discriminant Analysis (LDA), Extra Trees, AdaBoost, Gradient Boosting, XGBoost, LightGBM, and CatBoost. Performance was evaluated using the Area Under the Receiver Operating Characteristic Curve (AUC) and Brier Score for calibration. To address clinical safety, decision thresholds were optimized to maximize sensitivity. Clinical utility was assessed using Decision Curve Analysis to quantify net benefit across relevant risk thresholds.Results: The classical Gradient Boosting Classifier emerged as the top-performing model, achieving a mean AUC of 0.842 (95% CI: 0.82–0.86). It statistically outperformed both the linear baseline (LDA, AUC=0.833) and complex modern implementations such as XGBoost (AUC=0.787) and Extra Trees (AUC=0.748). By tuning the decision threshold to 0.01, the champion model achieved a screening Sensitivity of 86.0% and Specificity of 53.6%. SHAP (SHapley Additive exPlanations) analysis identified Age, Average Glucose Level, and BMI as the dominant non-linear predictors. Crucially, Decision Curve Analysis demonstrated that the Gradient Boosting model provided a higher net clinical benefit than "treat-all" or "treat-none" strategies across threshold probabilities of 1% to 40%.Conclusion: Contrary to current trends favoring deep learning or complex boosting implementations, classical Gradient Boosting architectures demonstrated superior generalization on imbalanced tabular clinical data. The developed model combines high discriminatory power with proven clinical utility, supporting its deployment as an automated, high-sensitivity screening tool in primary care settings.
- 22 January 2026
- Published by MDPI AG in Preprints.org
Open AccessBenchmarking Ensemble Machine Learning Algorithms for the Early Prediction of Stroke in Imbalanced Clinical Cohorts: A Comparative Analysis and Decision Curve Assessment
Background: Stroke remains a leading cause of mortality and long-term disability globally, necessitating effective primary prevention strategies. While machine learning (ML) models offer superior predictive capabilities compared to traditional linear risk scores, their application in clinical practice is often hindered by the "class imbalance" problem, where the rarity of stroke events leads to biased, low-sensitivity models. Furthermore, the literature currently lacks rigorous head-to-head benchmarking of modern boosting algorithms on moderate-sized clinical datasets. This study aimed to identify the optimal predictive model for stroke by systematically benchmarking seven ensemble algorithms and validating their clinical utility using Decision Curve Analysis (DCA).Methods: We analyzed a retrospective multi-center cohort of 5,110 patients, characterized by a severe class imbalance (4.9% stroke incidence). Feature engineering included the encoding of sociodemographic determinants and clinical biomarkers. We conducted a rigorous 10-fold stratified cross-validation tournament to compare seven classifiers: Linear Discriminant Analysis (LDA), Extra Trees, AdaBoost, Gradient Boosting, XGBoost, LightGBM, and CatBoost. Performance was evaluated using the Area Under the Receiver Operating Characteristic Curve (AUC) and Brier Score for calibration. To address clinical safety, decision thresholds were optimized to maximize sensitivity. Clinical utility was assessed using Decision Curve Analysis to quantify net benefit across relevant risk thresholds.Results: The classical Gradient Boosting Classifier emerged as the top-performing model, achieving a mean AUC of 0.842 (95% CI: 0.82–0.86). It statistically outperformed both the linear baseline (LDA, AUC=0.833) and complex modern implementations such as XGBoost (AUC=0.787) and Extra Trees (AUC=0.748). By tuning the decision threshold to 0.01, the champion model achieved a screening Sensitivity of 86.0% and Specificity of 53.6%. SHAP (SHapley Additive exPlanations) analysis identified Age, Average Glucose Level, and BMI as the dominant non-linear predictors. Crucially, Decision Curve Analysis demonstrated that the Gradient Boosting model provided a higher net clinical benefit than "treat-all" or "treat-none" strategies across threshold probabilities of 1% to 40%.Conclusion: Contrary to current trends favoring deep learning or complex boosting implementations, classical Gradient Boosting architectures demonstrated superior generalization on imbalanced tabular clinical data. The developed model combines high discriminatory power with proven clinical utility, supporting its deployment as an automated, high-sensitivity screening tool in primary care settings.