Kaiqi Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kaiqi Zhang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Hao Guo
State key Laboratory of Extreme Environment Optoelectronic Dynamic Testing Technology and Instrument, Shanxi Province Key Laboratory of Quantum Sensing and Precision Measurement, North University of China, Taiyuan, China
2 shared publications - Huan Fei Wen
North University of China
2 shared publications - Jun Liu
North University of China
2 shared publications - Jun Tang
State key Laboratory of Extreme Environment Optoelectronic Dynamic Testing Technology and Instrument, Shanxi Province Key Laboratory of Quantum Sensing and Precision Measurement, North University of China, Taiyuan, China
2 shared publications - Xin Li
School of Instrument and Electronics, North University of China, Taiyuan, Shanxi, China
2 shared publications - Yan Jun Li
Osaka University
2 shared publications
Latest Publications
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Noninvasive Microwave Distribution Imaging With High-Frequency Resolution Using NV Centers in Diamond
The characterization of microwave fields holds significant engineering importance in high-frequency chip design and performance optimization. In this study, we propose a non-invasive wide-field imaging method based on the spectral hole-burning effect in optically detected magnetic resonance (ODMR). This wide-field imaging method enables imaging of microwave fields at different frequencies under near-field radiator operating conditions. Its feasibility is confirmed by characterizing near-field radiator-generated microwave fields across multiple frequency and power settings. Furthermore, the effectiveness of the method is validated through a comparative analysis of simulation results and experimental measurements. Under the current experimental conditions, the results show that the approach achieves a frequency resolution of 100 kHz over the range of the resonance region, a microwave detection sensitivity of 0.78 nT/Hz1/2, a spatial imaging resolution of 1.55 μm, and the minimum detectable power is 1 mW. The above methods indicate great potential for application in the fields of integrated circuit fault diagnosis, electromagnetic compatibility testing, and radio equipment parameter calibration.
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Noninvasive Microwave Distribution Imaging With High-Frequency Resolution Using NV Centers in Diamond
The characterization of microwave fields holds significant engineering importance in high-frequency chip design and performance optimization. In this study, we propose a non-invasive wide-field imaging method based on the spectral hole-burning effect in optically detected magnetic resonance (ODMR). This wide-field imaging method enables imaging of microwave fields at different frequencies under near-field radiator operating conditions. Its feasibility is confirmed by characterizing near-field radiator-generated microwave fields across multiple frequency and power settings. Furthermore, the effectiveness of the method is validated through a comparative analysis of simulation results and experimental measurements. Under the current experimental conditions, the results show that the approach achieves a frequency resolution of 100 kHz over the range of the resonance region, a microwave detection sensitivity of 0.78 nT/Hz1/2, a spatial imaging resolution of 1.55 μm, and the minimum detectable power is 1 mW. The above methods indicate great potential for application in the fields of integrated circuit fault diagnosis, electromagnetic compatibility testing, and radio equipment parameter calibration.
- 29 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Nondestructive Characterization of Subsurface Metal Microstructure Using Quantum Wide-Field Microscope
In order to meet the need for high-resolution, nondestructive inspection of subsurface metal microstructure, we propose a method for characterizing subsurface metal microstructure with high-resolution via quantum wide-field microscopy based on nitrogen-vacancy (NV) centers. In a view of 1050 × 1050 μm2, the feasibility of the method is verified by reconstructing the induced microwave field generated by far field free space microwaves in the metal microstructure using quantum microscopy. In addition, the induced microwave field are explored scrupulously at varying distances between quantum microscopy and metal microstructure. The results show that the method can detect subsurface metal microstructure at a distance of 1700 μm between the quantum microscopy and metal microstructure, with a vertical resolution of 10 μm, and optimal NV detection sensitivity is 0.75 nT/Hz1/2. A width detection sensitivity of 3.2 kHz/μm for metal microstructure can be achieved using this method. This work is critical for advancing the performance evaluation of engineered structures and the development of quantum testing techniques.
- 29 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Nondestructive Characterization of Subsurface Metal Microstructure Using Quantum Wide-Field Microscope
In order to meet the need for high-resolution, nondestructive inspection of subsurface metal microstructure, we propose a method for characterizing subsurface metal microstructure with high-resolution via quantum wide-field microscopy based on nitrogen-vacancy (NV) centers. In a view of 1050 × 1050 μm2, the feasibility of the method is verified by reconstructing the induced microwave field generated by far field free space microwaves in the metal microstructure using quantum microscopy. In addition, the induced microwave field are explored scrupulously at varying distances between quantum microscopy and metal microstructure. The results show that the method can detect subsurface metal microstructure at a distance of 1700 μm between the quantum microscopy and metal microstructure, with a vertical resolution of 10 μm, and optimal NV detection sensitivity is 0.75 nT/Hz1/2. A width detection sensitivity of 3.2 kHz/μm for metal microstructure can be achieved using this method. This work is critical for advancing the performance evaluation of engineered structures and the development of quantum testing techniques.