Camellia Ganjoury
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Camellia Ganjoury has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Mohammad-Mehdi Khani
Department of Tissue Engineering and Applied Cell Sciences, School of Advanced Technologies in Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
7 shared publications Faraz Sigaroodi
Department of Tissue Engineering and Applied Cell Sciences, School of Advanced Technologies in Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
5 shared publicationsAzim Parandakh
Medical Nanotechnology and Tissue Engineering Research Center Shahid Beheshti University of Medical Sciences Tehran Iran
4 shared publicationsNajmeh Najmoddin
Department of Biomedical Engineering, Medical Engineering and Biology Research Center, Science and Research Branch, Islamic Azad University
3 shared publicationsHanieh Lavarian
Medical Nanotechnology and Tissue Engineering Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
2 shared publicationsMohammad Tabatabaei
Department of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
2 shared publications
Latest Publications
- 18 October 2025
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 258, 115210
Injectable MXene-loaded decellularized pericardium hydrogels promote cardiac repair in rats with myocardial infarction
- 18 October 2025
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 258, 115210
Injectable MXene-loaded decellularized pericardium hydrogels promote cardiac repair in rats with myocardial infarction
- 19 September 2025
- Published by Taylor & Francis in Journal of Biomaterials Science, Polymer Edition
- Vol. 37 (9) , 1619-1637
Development of a fibrous poly (xylitol sebacate) sheet for endothelial basement membrane tissue engineering
An essential part of designing cardiovascular grafts is the fabrication of an artificial endothelial basement membrane (EBM) with the ability to support endothelial differentiation, especially under physiological dynamic forces. In this study, we introduce a novel artificial EBM constructed from a poly (xylitol sebacate) (PXS) polymer. First, the PXS prepolymer (pPXS) was blended with polyvinyl alcohol (PVA) at different ratios to achieve optimized production with a minimum amount of PVA to fabricate well-organized electrospun fiber networks of pPXS/PVA. Subsequently, pPXS/PVA was cross-linked at 120 °C under vacuum for two days to form a cPXS/PVA meshwork. Then, PVA and remaining pPXS were removed from the cPXS/PVA meshworks by serial rinsing in deionized water and ethanol to fabricate a defect-free fibrous sheet of cPXS. The fibrous cPXS sheets were characterized in terms of their structural, mechanical, and biological performance. The results confirmed that the cPXS sheets exhibited appropriate mechanical strength, acceptable wettability, ideal porosity, degradation behavior, and superior biocompatibility. Moreover, cPXS, as an artificial EBM, is capable of supporting endothelial differentiation of mesenchymal stem cells under dynamic culture conditions in a parallel plate bioreactor. Therefore, it can be inferred that fibrous cPXS sheet can be an ideal candidate for EBM tissue engineering and development of functional cardiovascular grafts.
- 19 September 2025
- Published by Taylor & Francis in Journal of Biomaterials Science, Polymer Edition
- Vol. 37 (9) , 1619-1637
Development of a fibrous poly (xylitol sebacate) sheet for endothelial basement membrane tissue engineering
An essential part of designing cardiovascular grafts is the fabrication of an artificial endothelial basement membrane (EBM) with the ability to support endothelial differentiation, especially under physiological dynamic forces. In this study, we introduce a novel artificial EBM constructed from a poly (xylitol sebacate) (PXS) polymer. First, the PXS prepolymer (pPXS) was blended with polyvinyl alcohol (PVA) at different ratios to achieve optimized production with a minimum amount of PVA to fabricate well-organized electrospun fiber networks of pPXS/PVA. Subsequently, pPXS/PVA was cross-linked at 120 °C under vacuum for two days to form a cPXS/PVA meshwork. Then, PVA and remaining pPXS were removed from the cPXS/PVA meshworks by serial rinsing in deionized water and ethanol to fabricate a defect-free fibrous sheet of cPXS. The fibrous cPXS sheets were characterized in terms of their structural, mechanical, and biological performance. The results confirmed that the cPXS sheets exhibited appropriate mechanical strength, acceptable wettability, ideal porosity, degradation behavior, and superior biocompatibility. Moreover, cPXS, as an artificial EBM, is capable of supporting endothelial differentiation of mesenchymal stem cells under dynamic culture conditions in a parallel plate bioreactor. Therefore, it can be inferred that fibrous cPXS sheet can be an ideal candidate for EBM tissue engineering and development of functional cardiovascular grafts.
- 20 July 2024
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 112 (8) , e35449
The landscape of clinical trials in corneal regeneration: A systematic review of tissue engineering approaches in corneal disease
The limited availability of a healthy donor cornea and the incidence of allograft failure led researchers to seek other corneal substitutes via tissue engineering. Exploring the trend of clinical trials of the cornea with the vision of tissue engineering provides an opportunity to reveal future potential corneal substitutes. The results of this clinical trial are beneficial for future study designs to overcome the limitations of current therapeutic approaches. In this study, registered clinical trials of bio‐based approaches were reviewed for corneal regeneration on March 22, 2024. Among the 3955 registered trials for the cornea, 392 trials were included in this study, which categorized in three main bio‐based scaffolds, stem cells, and bioactive macromolecules. In addition to the acellular cornea and human amniotic membrane, several bio‐based materials have been introduced as corneal substrates such as collagen, fibrin, and agarose. However, some synthetic materials have been introduced in recent studies to improve the desired properties of bio‐based scaffolds for corneal substitutes. Nevertheless, new insights into corneal regenerative medicine have recently emerged from cell sheets with autologous and allogeneic cell sources. In addition, the future perspective of corneal regeneration is described through a literature review of recent experimental models.
- 20 July 2024
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 112 (8) , e35449
The landscape of clinical trials in corneal regeneration: A systematic review of tissue engineering approaches in corneal disease
The limited availability of a healthy donor cornea and the incidence of allograft failure led researchers to seek other corneal substitutes via tissue engineering. Exploring the trend of clinical trials of the cornea with the vision of tissue engineering provides an opportunity to reveal future potential corneal substitutes. The results of this clinical trial are beneficial for future study designs to overcome the limitations of current therapeutic approaches. In this study, registered clinical trials of bio‐based approaches were reviewed for corneal regeneration on March 22, 2024. Among the 3955 registered trials for the cornea, 392 trials were included in this study, which categorized in three main bio‐based scaffolds, stem cells, and bioactive macromolecules. In addition to the acellular cornea and human amniotic membrane, several bio‐based materials have been introduced as corneal substrates such as collagen, fibrin, and agarose. However, some synthetic materials have been introduced in recent studies to improve the desired properties of bio‐based scaffolds for corneal substitutes. Nevertheless, new insights into corneal regenerative medicine have recently emerged from cell sheets with autologous and allogeneic cell sources. In addition, the future perspective of corneal regeneration is described through a literature review of recent experimental models.
- 14 June 2024
- Published by Wiley in Polymer International
- Vol. 73 (10) , 844-851
Cardiomyocyte differentiation of umbilical cord mesenchymal stem cells on poly(mannitol sebacate)/multi‐walled carbon nanotube substrate
Myocardial infarction is one of the main causes of death worldwide. After myocardial infarction, the damaged area is typically occupied with non‐contractile scar tissue owing to the limited ability of cardiac cells to proliferate. Cardiac patches can potentially restore heart function by providing sufficient electrochemical properties to the damaged area and supporting the differentiation into and proliferation of cardiac cells. In this study, we developed for the first time a poly(mannitol sebacate) (PMS) based scaffold combined with 1% (w/w)multi‐walled carbon nanotubes (MWCNTs) to produce a biocompatible cardiac patch by the solvent casting method. We characterized the resultant PMS‐MWCNT scaffold in terms of chemical, physical, mechanical and electrical properties. The PMS/MWCNT patch revealed appropriate hydrophilicity, elasticity close to that of the target tissue, and electrical conductivity suited for a cardiac patch. The cytocompatibility of the composite was confirmed by the successful attachment and proliferation of human umbilical cord mesenchymal stem cells (HUC‐MSCs). The PMS/MWCNTs further contributed to the differentiation of HUC‐MSCs by significant overexpression of cardiac‐specific proteins, i.e. troponin T and connexin 43, in the presence of 5‐azacytidine. The findings of this study could be of assistance in the use and development of PMS‐based composites as cardiac patches for myocardial tissue engineering applications. © 2024 Society of Chemical Industry.
- 14 June 2024
- Published by Wiley in Polymer International
- Vol. 73 (10) , 844-851
Cardiomyocyte differentiation of umbilical cord mesenchymal stem cells on poly(mannitol sebacate)/multi‐walled carbon nanotube substrate
Myocardial infarction is one of the main causes of death worldwide. After myocardial infarction, the damaged area is typically occupied with non‐contractile scar tissue owing to the limited ability of cardiac cells to proliferate. Cardiac patches can potentially restore heart function by providing sufficient electrochemical properties to the damaged area and supporting the differentiation into and proliferation of cardiac cells. In this study, we developed for the first time a poly(mannitol sebacate) (PMS) based scaffold combined with 1% (w/w)multi‐walled carbon nanotubes (MWCNTs) to produce a biocompatible cardiac patch by the solvent casting method. We characterized the resultant PMS‐MWCNT scaffold in terms of chemical, physical, mechanical and electrical properties. The PMS/MWCNT patch revealed appropriate hydrophilicity, elasticity close to that of the target tissue, and electrical conductivity suited for a cardiac patch. The cytocompatibility of the composite was confirmed by the successful attachment and proliferation of human umbilical cord mesenchymal stem cells (HUC‐MSCs). The PMS/MWCNTs further contributed to the differentiation of HUC‐MSCs by significant overexpression of cardiac‐specific proteins, i.e. troponin T and connexin 43, in the presence of 5‐azacytidine. The findings of this study could be of assistance in the use and development of PMS‐based composites as cardiac patches for myocardial tissue engineering applications. © 2024 Society of Chemical Industry.
- 1 June 2023
- Published by Springer Nature in In Vitro Cellular & Developmental Biology - Animal
- Vol. 59 (6) , 401-409
Nanoscale vibration could promote tenogenic differentiation of umbilical cord mesenchymal stem cells
Regulation of mesenchymal stem cell (MSC) fate for targeted cell therapy applications has been a subject of interest, particularly for tissues such as tendons that possess a marginal regenerative capacity. Control of MSCs’ fate into the tendon-specific lineage has mainly been achieved by implementation of chemical growth factors. Mechanical stimuli or 3-dimensional (D) scaffolds have been used as an additional tool for the differentiation of MSCs into tenocytes, but oftentimes, they require a sophisticated bioreactor or a complex scaffold fabrication technique which reduces the feasibility of the proposed method to be used in practice. Here, we used nanovibration to induce the differentiation of MSCs toward the tenogenic fate solely by the use of nanovibration and without the need for growth factors or complex scaffolds. MSCs were cultured on 2D cell culture dishes that were connected to piezo ceramic arrays to apply nanovibration (30–80 nm and 1 kHz frequency) over 7 and 14 d. We observed that nanovibration resulted in significant overexpression of tendon-related markers in both gene expression and protein expression levels, while there was no significant differentiation into adipose and cartilage lineages. These findings could be of assistance in the mechanoregulation of MSCs for stem cell engineering and regenerative medicine applications.
- 1 June 2023
- Published by Springer Nature in In Vitro Cellular & Developmental Biology - Animal
- Vol. 59 (6) , 401-409
Nanoscale vibration could promote tenogenic differentiation of umbilical cord mesenchymal stem cells
Regulation of mesenchymal stem cell (MSC) fate for targeted cell therapy applications has been a subject of interest, particularly for tissues such as tendons that possess a marginal regenerative capacity. Control of MSCs’ fate into the tendon-specific lineage has mainly been achieved by implementation of chemical growth factors. Mechanical stimuli or 3-dimensional (D) scaffolds have been used as an additional tool for the differentiation of MSCs into tenocytes, but oftentimes, they require a sophisticated bioreactor or a complex scaffold fabrication technique which reduces the feasibility of the proposed method to be used in practice. Here, we used nanovibration to induce the differentiation of MSCs toward the tenogenic fate solely by the use of nanovibration and without the need for growth factors or complex scaffolds. MSCs were cultured on 2D cell culture dishes that were connected to piezo ceramic arrays to apply nanovibration (30–80 nm and 1 kHz frequency) over 7 and 14 d. We observed that nanovibration resulted in significant overexpression of tendon-related markers in both gene expression and protein expression levels, while there was no significant differentiation into adipose and cartilage lineages. These findings could be of assistance in the mechanoregulation of MSCs for stem cell engineering and regenerative medicine applications.
- 7 November 2022
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 34 (2) , 740-747
Enhancing endothelial differentiation of human mesenchymal stem cells by culture on a nanofibrous polycaprolactone/(poly‐glycerol sebacate)/gelatin scaffold
Cardiovascular diseases have always been one of the main causes of death worldwide and eventually one of the major medical concerns. Tissue engineering is promising strategies of treating cardiovascular, which can be an effective approach with the design of appropriate scaffold. In this study, to develop engineering basement membrane for endothelial differentiation with good cell attachment, we produced polycaprolactone (PCL)/poly (glycerol sebacate) (PGS)/gelatin nanofibrous scaffold via electrospinning. Attenuated total reflectance‐Fourier transform infrared and the proton nuclear magnetic resonance results confirmed the chemical structure of synthesized PGS. Scanning electron microscope images of the electrospun scaffold revealed that the nanofibers are smooth, continues and uniform. Moreover, due to the presence of hydrophilic functional groups in the scaffold, the contact angle is in the appropriate range for cell adhesion especially endothelial cells. The elastic modulus and ultimate tensile stress of electrospun scaffold were calculated 1.32 ± 0.27 MPa and 1.23 ± 0.18 MPa respectively. Quantitative polymerase chain reaction was performed for evaluation of endothelial differentiation of mesenchymal stem cells cultured on standard plate and fibrous scaffold under chemical stimulation with growth factor. Specific endothelial gene expression results postulated that our modified scaffold could support and significantly promote endothelial differentiation of MSCs.
- 7 November 2022
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 34 (2) , 740-747
Enhancing endothelial differentiation of human mesenchymal stem cells by culture on a nanofibrous polycaprolactone/(poly‐glycerol sebacate)/gelatin scaffold
Cardiovascular diseases have always been one of the main causes of death worldwide and eventually one of the major medical concerns. Tissue engineering is promising strategies of treating cardiovascular, which can be an effective approach with the design of appropriate scaffold. In this study, to develop engineering basement membrane for endothelial differentiation with good cell attachment, we produced polycaprolactone (PCL)/poly (glycerol sebacate) (PGS)/gelatin nanofibrous scaffold via electrospinning. Attenuated total reflectance‐Fourier transform infrared and the proton nuclear magnetic resonance results confirmed the chemical structure of synthesized PGS. Scanning electron microscope images of the electrospun scaffold revealed that the nanofibers are smooth, continues and uniform. Moreover, due to the presence of hydrophilic functional groups in the scaffold, the contact angle is in the appropriate range for cell adhesion especially endothelial cells. The elastic modulus and ultimate tensile stress of electrospun scaffold were calculated 1.32 ± 0.27 MPa and 1.23 ± 0.18 MPa respectively. Quantitative polymerase chain reaction was performed for evaluation of endothelial differentiation of mesenchymal stem cells cultured on standard plate and fibrous scaffold under chemical stimulation with growth factor. Specific endothelial gene expression results postulated that our modified scaffold could support and significantly promote endothelial differentiation of MSCs.