Yongchun Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yongchun Li has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Pei Qin
South China University of Technology
6 shared publications - Quan Xue
South China University of Technology
5 shared publications - Wenquan Che
South China University of Technology
4 shared publications - Taotao Xu
Guangdong Provincial Key Laboratory of Millimeter-Wave and Terahertz and the School of Electronic and Information Engineering, South China University of Technology, Guangzhou, China
3 shared publications - Haoshen Zhu
South China University of Technology
2 shared publications Junyu Wu
Guangdong Provincial Key Laboratory of Millimeter-Wave and Terahertz and the School of Electronic and Information Engineering, South China University of Technology, Guangzhou, China
2 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 74 (11) , 9589-9601
A 23--40 GHz Compact LNA Using Quad-Coil Coupled Transformer for Dual-Path Noise Cancellation
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 74 (11) , 9589-9601
A 23--40 GHz Compact LNA Using Quad-Coil Coupled Transformer for Dual-Path Noise Cancellation
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 74 (10) , 8832-8846
An 18--36.6-GHz Common-Gate LNA With Broadband Simultaneous Noise and Input Impedance Matching
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 74 (10) , 8832-8846
An 18--36.6-GHz Common-Gate LNA With Broadband Simultaneous Noise and Input Impedance Matching
- 11 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Technology Letters
- Vol. PP (2771957X) , 1-4
A 24.1–31.8-GHz Ultracompact LNA With Dual-Stage Noise Cancellation by Multicoil Transformers
This letter presents an ultracompact 24.1–31.8-GHz low-noise amplifier (LNA) with dual-stage noise cancellation (NC) by multicoil transformers. The proposed LNA features two cascaded common source (CS) stages, with a common gate (CG) stage inserted between them to help optimize the noise contribution from both the first and second stages. To achieve dual-stage NC, the NC paths at first stage and second stage are constructed based on a triple-coil transformer combined with a dual-coil transformer. These multicoil transformers enable NC and reduce chip area. Fabricated in 65-nm CMOS technology, the LNA achieves a maximum gain of 14.3 dB with a 3-dB bandwidth (BW) of 24.1–31.8 GHz and a minimum noise figure (NF) of 2.68 dB. The circuit consumes 12.4 mW under a 1-V supply, with an in-band input 1-dB compression point (IP1dB) ranging from −20 to −13.2 dBm. The entire design occupies a core area of only 0.066 mm2.
- 11 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Technology Letters
- Vol. PP (2771957X) , 1-4
A 24.1–31.8-GHz Ultracompact LNA With Dual-Stage Noise Cancellation by Multicoil Transformers
This letter presents an ultracompact 24.1–31.8-GHz low-noise amplifier (LNA) with dual-stage noise cancellation (NC) by multicoil transformers. The proposed LNA features two cascaded common source (CS) stages, with a common gate (CG) stage inserted between them to help optimize the noise contribution from both the first and second stages. To achieve dual-stage NC, the NC paths at first stage and second stage are constructed based on a triple-coil transformer combined with a dual-coil transformer. These multicoil transformers enable NC and reduce chip area. Fabricated in 65-nm CMOS technology, the LNA achieves a maximum gain of 14.3 dB with a 3-dB bandwidth (BW) of 24.1–31.8 GHz and a minimum noise figure (NF) of 2.68 dB. The circuit consumes 12.4 mW under a 1-V supply, with an in-band input 1-dB compression point (IP1dB) ranging from −20 to −13.2 dBm. The entire design occupies a core area of only 0.066 mm2.
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. PP (00189200) , 1-14
A Compact Reconfigurable Dual-Path Dual-Band LNA for 5G NR FR2 Applications
This article presents a reconfigurable dual-path dual-band low noise amplifier (LNA) for fifth generation (5G) millimeter-wave (mmW) communications. A novel band-switching input matching architecture based on the cross-connected transistors is proposed to achieve optimal dual-band input matching and $g_{m}$ -boosting. This architecture allows the dual-band input transistors to share a tri-coupled-transformer-based input matching network (MN) while maintaining independent output paths. Furthermore, an 8-shaped transformer-based decoupling interstage MN provides optimal interstage impedance matching in the low-band and high-band modes while sharing the same footprints with negligible performance degradation. In addition, to suppress interference from image bands, a notch filter based on negative resistance is integrated into the output MN. A prototype of the proposed LNA was fabricated in TSMC 65-nm bulk CMOS process with a compact core size of 0.132 mm2. The measurement results show that the proposed LNA covers the n257 and n260 bands, achieving a peak gain of 17.8/17.9 dB at 28/37.1 GHz and image rejection (IR) of 37.4/25.9 dBc at 38.2/28.5 GHz, respectively. The measured noise figure (NF) reaches minimum values of 3.23/3.63 dB at 28/37.8 GHz. Moreover, the power consumptions of the two modes are 19.9 and 21.2 mW, respectively, from a 1.0-V supply voltage.
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. PP (00189200) , 1-14
A Compact Reconfigurable Dual-Path Dual-Band LNA for 5G NR FR2 Applications
This article presents a reconfigurable dual-path dual-band low noise amplifier (LNA) for fifth generation (5G) millimeter-wave (mmW) communications. A novel band-switching input matching architecture based on the cross-connected transistors is proposed to achieve optimal dual-band input matching and $g_{m}$ -boosting. This architecture allows the dual-band input transistors to share a tri-coupled-transformer-based input matching network (MN) while maintaining independent output paths. Furthermore, an 8-shaped transformer-based decoupling interstage MN provides optimal interstage impedance matching in the low-band and high-band modes while sharing the same footprints with negligible performance degradation. In addition, to suppress interference from image bands, a notch filter based on negative resistance is integrated into the output MN. A prototype of the proposed LNA was fabricated in TSMC 65-nm bulk CMOS process with a compact core size of 0.132 mm2. The measurement results show that the proposed LNA covers the n257 and n260 bands, achieving a peak gain of 17.8/17.9 dB at 28/37.1 GHz and image rejection (IR) of 37.4/25.9 dBc at 38.2/28.5 GHz, respectively. The measured noise figure (NF) reaches minimum values of 3.23/3.63 dB at 28/37.8 GHz. Moreover, the power consumptions of the two modes are 19.9 and 21.2 mW, respectively, from a 1.0-V supply voltage.
- 6 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 73 (3) , 243-247
A Compact V -Band Quad-Core VCO With Coupling-Coexistence and Dual-Filtering Techniques
This paper proposes a compact and low phase noise (PN) V-Band quad-core voltage-controlled oscillator (VCO) in a 28-nm CMOS technology, capable of extracting third-harmonic frequencies for D-band integrated sensing and communication (ISAC) systems. Coupling-coexistence technique based on a tricoupled transformer and dual-filtering technique enhance PN without additional area. A compact snowflake geometry topology is proposed, employing both inductor-sharing and moderejection techniques. The measured quad-core VCO tunes from 49.8 to 53.9 GHz, achieving -94.2 dBc/Hz and -121.1 dBc/Hz optimal phase noise (PN) at 1 MHz and 10 MHz offset, respectively, at 53.6 GHz carrier. The design also achieves the comparable area and power consumption of a single-core oscillator, combined with the PN performance advantages of multi-core oscillators, achieving a high FoMA of -200.1 dBc/Hz.
- 6 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 73 (3) , 243-247
A Compact V -Band Quad-Core VCO With Coupling-Coexistence and Dual-Filtering Techniques
This paper proposes a compact and low phase noise (PN) V-Band quad-core voltage-controlled oscillator (VCO) in a 28-nm CMOS technology, capable of extracting third-harmonic frequencies for D-band integrated sensing and communication (ISAC) systems. Coupling-coexistence technique based on a tricoupled transformer and dual-filtering technique enhance PN without additional area. A compact snowflake geometry topology is proposed, employing both inductor-sharing and moderejection techniques. The measured quad-core VCO tunes from 49.8 to 53.9 GHz, achieving -94.2 dBc/Hz and -121.1 dBc/Hz optimal phase noise (PN) at 1 MHz and 10 MHz offset, respectively, at 53.6 GHz carrier. The design also achieves the comparable area and power consumption of a single-core oscillator, combined with the PN performance advantages of multi-core oscillators, achieving a high FoMA of -200.1 dBc/Hz.
- 23 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Technology Letters
- Vol. PP (2771957X) , 1-4
An 8.3–43 GHz CMOS Low-Noise Amplifier With Wideband Input Matching
An 8.3–43-GHz CMOS low-noise amplifier (LNA) with wideband input matching is presented. A gate–drain transformer feedback combined with a series–shunt resonance network is employed in a complementary common-source (CCS) input stage to achieve a broadband, impedance-stable input, and noise matching. A transformer-loaded cascode output stage is implemented to enhance gain, while a pole-tuning technique is adopted to achieve a broadband gain response. Fabricated in 65-nm CMOS, the LNA achieves a peak gain of 14.7 dB and a 3-dB bandwidth from 8.3 to 43GHz with a fractional bandwidth of 135.3%. Good input matching is maintained across 8–55GHz. The input 1-dB compression point (IP ${}_{\mathrm {1dB}}$ ) ranges from –14.3 to –9.3 dBm. A minimum noise figure (NF) of 3.47 dB is measured, and the power consumption is 25.9 mW under a 1.2-V supply.
- 23 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Technology Letters
- Vol. PP (2771957X) , 1-4
An 8.3–43 GHz CMOS Low-Noise Amplifier With Wideband Input Matching
An 8.3–43-GHz CMOS low-noise amplifier (LNA) with wideband input matching is presented. A gate–drain transformer feedback combined with a series–shunt resonance network is employed in a complementary common-source (CCS) input stage to achieve a broadband, impedance-stable input, and noise matching. A transformer-loaded cascode output stage is implemented to enhance gain, while a pole-tuning technique is adopted to achieve a broadband gain response. Fabricated in 65-nm CMOS, the LNA achieves a peak gain of 14.7 dB and a 3-dB bandwidth from 8.3 to 43GHz with a fractional bandwidth of 135.3%. Good input matching is maintained across 8–55GHz. The input 1-dB compression point (IP ${}_{\mathrm {1dB}}$ ) ranges from –14.3 to –9.3 dBm. A minimum noise figure (NF) of 3.47 dB is measured, and the power consumption is 25.9 mW under a 1.2-V supply.
- 31 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Technology Letters
- Vol. 35 (11) , 1835-1838
High-Linearity CMOS VCO for FMCW Radar
This letter proposes a novel structure of mm-wave (mmW) high-linearity voltage-controlled oscillator (VCO), which comprises an 8-GHz VCO and a current/function-reused frequency tripler (FT). Based on the least squares method, a theoretical approach is proposed to determine the optimal varactor value that achieves the maximum linearity using a single-analog control voltage. Implemented in the 65-nm CMOS technology, the high-linearity mmW VCO obtains a $K_{\text {VCO}}$ variation of lower than 5.35% over the frequency range from 23.24 to 25.89 GHz. And with an off-chip phase-locked loop (PLL), a 24-GHz frequency-modulated continuous-wave (FMCW) radar system is developed and measured to verify the proposed VCO.
- 31 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Technology Letters
- Vol. 35 (11) , 1835-1838
High-Linearity CMOS VCO for FMCW Radar
This letter proposes a novel structure of mm-wave (mmW) high-linearity voltage-controlled oscillator (VCO), which comprises an 8-GHz VCO and a current/function-reused frequency tripler (FT). Based on the least squares method, a theoretical approach is proposed to determine the optimal varactor value that achieves the maximum linearity using a single-analog control voltage. Implemented in the 65-nm CMOS technology, the high-linearity mmW VCO obtains a $K_{\text {VCO}}$ variation of lower than 5.35% over the frequency range from 23.24 to 25.89 GHz. And with an off-chip phase-locked loop (PLL), a 24-GHz frequency-modulated continuous-wave (FMCW) radar system is developed and measured to verify the proposed VCO.
- Open Access
- 20 August 2023
- Vol. 26 (8) , 630-638
[Progress in Image-planned and Real-time Image-guided Lung Cancer Biopsy in the Detection of Biomarkers].
With the progress of targeted therapy and immunotherapy for lung cancer, the clinical demand for lung biopsy is increasing. An ideal biopsy specimen can be used not only for histopathological diagnosis, but also for biomarker detection. The ideal biopsy specimen should meet two requirements, including more than 60 mm2 of tumor tissue and containing more than 20% of tumor cells. In order to obtain ideal lung cancer biopsy specimens, advanced imaging techniques are needed to help. In this article, we reviewed the requirements for biopsy specimens based on biomarker detection, as well as the current status and research progress of using imaging techniques for preoperative planning and intraoperative real time guidance of lung cancer biopsy. .
- 20 August 2023
- Vol. 26 (8) , 630-638
Open Access[Progress in Image-planned and Real-time Image-guided Lung Cancer Biopsy in the Detection of Biomarkers].
With the progress of targeted therapy and immunotherapy for lung cancer, the clinical demand for lung biopsy is increasing. An ideal biopsy specimen can be used not only for histopathological diagnosis, but also for biomarker detection. The ideal biopsy specimen should meet two requirements, including more than 60 mm2 of tumor tissue and containing more than 20% of tumor cells. In order to obtain ideal lung cancer biopsy specimens, advanced imaging techniques are needed to help. In this article, we reviewed the requirements for biopsy specimens based on biomarker detection, as well as the current status and research progress of using imaging techniques for preoperative planning and intraoperative real time guidance of lung cancer biopsy. .
- Open Access
- 1 November 2021
- Published by AME Publishing Company in Annals of Palliative Medicine
- Vol. 10 (11) , 11901-11909
Effect of cardiac rehabilitation training on patients with coronary heart disease: a systematic review and meta-analysis
Background: In recent years, the incidence of heart disease has increased and patients are younger. Cardiac rehabilitation training has been proposed to improve the prognosis of patients with heart disease. Cardiac rehabilitation includes moderate-intensity continuous training (MCT) and high-intensity interval training (HIIT). These two training methods have different effects in improving the prognosis of patients. The aim of the present study was to improve reference for patients with cardiac rehabilitation. Methods: English databases, including PubMed, Cochrane Library, and Embase, were searched from the establishment of the database to April 2021 for randomized controlled trials (RCTs) of rehabilitation training at different intensities. RevMan 5.3 was used for the meta-analysis. Results: A total of 8 articles (with a total of 465 patients) were included, including 236 patients in the experimental group and 229 patients in the control group. Different intensities of training had statistically significant differences in peak oxygen uptake [mean difference (MD): 1.21, 95% confidence interval (CI): −0.66 to 3.07, P=0.20] and the left ventricular ejection fraction difference (MD: 2.53, 95% CI: −2.10 to 7.17, P=0.28). Discussion: Cardiac rehabilitation training can effectively improve the patient’s cardiac function indicators and self-care ability, and reduce the incidence of cardiovascular disease (CVD). However, large-sample, multicenter, and long-term RCTs are needed to strengthen the findings of the study.
- 1 November 2021
- Published by AME Publishing Company in Annals of Palliative Medicine
- Vol. 10 (11) , 11901-11909
Open AccessEffect of cardiac rehabilitation training on patients with coronary heart disease: a systematic review and meta-analysis
Background: In recent years, the incidence of heart disease has increased and patients are younger. Cardiac rehabilitation training has been proposed to improve the prognosis of patients with heart disease. Cardiac rehabilitation includes moderate-intensity continuous training (MCT) and high-intensity interval training (HIIT). These two training methods have different effects in improving the prognosis of patients. The aim of the present study was to improve reference for patients with cardiac rehabilitation. Methods: English databases, including PubMed, Cochrane Library, and Embase, were searched from the establishment of the database to April 2021 for randomized controlled trials (RCTs) of rehabilitation training at different intensities. RevMan 5.3 was used for the meta-analysis. Results: A total of 8 articles (with a total of 465 patients) were included, including 236 patients in the experimental group and 229 patients in the control group. Different intensities of training had statistically significant differences in peak oxygen uptake [mean difference (MD): 1.21, 95% confidence interval (CI): −0.66 to 3.07, P=0.20] and the left ventricular ejection fraction difference (MD: 2.53, 95% CI: −2.10 to 7.17, P=0.28). Discussion: Cardiac rehabilitation training can effectively improve the patient’s cardiac function indicators and self-care ability, and reduce the incidence of cardiovascular disease (CVD). However, large-sample, multicenter, and long-term RCTs are needed to strengthen the findings of the study.
- 1 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 843-847
Stereo matching algorithm based on binocular vision
Binocular stereo vision technology has been widely used in target detection, unmanned driving and other aspects due to its advantages of low cost and wide range of application. It is a research hotspot in the field of computer vision. Binocular stereo vision is mainly to obtain 3D depth information of the scene by analyzing two or more views of the scene. Stereo matching is the core part of the scene, and the performance of the matching algorithm directly affects the effect of 3D reconstruction. This paper mainly analyzes and summarizes the local stereo matching algorithm, global stereo matching algorithm and semi-global stereo matching algorithm by studying stereo matching algorithms at home and abroad, expounds the characteristics and performance of various matching algorithms, and makes a comparative analysis of various algorithms.
- 1 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 843-847
Stereo matching algorithm based on binocular vision
Binocular stereo vision technology has been widely used in target detection, unmanned driving and other aspects due to its advantages of low cost and wide range of application. It is a research hotspot in the field of computer vision. Binocular stereo vision is mainly to obtain 3D depth information of the scene by analyzing two or more views of the scene. Stereo matching is the core part of the scene, and the performance of the matching algorithm directly affects the effect of 3D reconstruction. This paper mainly analyzes and summarizes the local stereo matching algorithm, global stereo matching algorithm and semi-global stereo matching algorithm by studying stereo matching algorithms at home and abroad, expounds the characteristics and performance of various matching algorithms, and makes a comparative analysis of various algorithms.