Mohamad Bader Abo Hajar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohamad Bader Abo Hajar has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
Colleen Parro
Baylor Scott & White Research Institute Dallas Texas USA
3 shared publicationsGhadi Moubarak
Baylor Scott & White Research Institute Dallas Texas USA
3 shared publications- Kyle A. McCullough
Department of Cardiovascular Research, Baylor Scott and White Research Institute, Plano, Texas, United States
3 shared publications Maya Elias
Baylor Scott & White Research Institute Dallas Texas USA
3 shared publications- Srinivasa Potluri
Department of Cardiology, Baylor Scott & White The Heart Hospital, Plano, Texas
3 shared publications Amro Alsaid
2 shared publications
Latest Publications
- 8 February 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 107 (5) , 1484-1493
Five‐Year Outcomes of Measured and Predicted Prosthesis‐Patient Mismatch Following Valve‐in‐Valve Transcatheter Aortic Valve Implantation
Background: This study's objective was to investigate the incidence and long‐term outcomes of measured (PPM M ) and predicted (PPM P ) prosthesis‐patient mismatch in patients undergoing valve‐in‐valve (ViV) transcatheter aortic valve implantation (TAVI). Aims: To assess the outcomes of predicted and measured PPM in patients undergoing ViV TAVI. Methods: This retrospective, multicenter analysis included patients who underwent ViV TAVI at the Baylor Scott & White Health‐Care System between 2012 and 2021. Effective orifice area (EOA) was measured at discharge using transthoracic echocardiography and indexed to body surface area (EOAi), and predicted EOAi was derived from published reference values according to valve type and size. PPM was classified using standard EOAi cutoff values and subsequently reclassified using obesity‐adjusted EOAi thresholds for patients with body mass index ≥ 30 kg/m². Results: A total of 162 patients treated with ViV‐TAVI were analyzed: 64.8% were male, 34% had a BMI ≥ 30kg/m², and the median age was 77 [69.2; 84.0] years. The median STS risk score was 6.3 [3.5; 9.65] %. TAVI was performed trans‐femorally in 95.7%, using balloon‐expandable (52.5%) and self‐expanding (47.5%) devices. The incidence of severe PPMP was significantly lower than that of severe PPMM, both before (14.8% vs. 28.4%, p = 0.005) and after adjusting for BMI (11.1% vs. 24.7%, p = 0.002). Both severe PPMP and PPMM predicted high residual pressure gradient (≥ 20mmHg) ( p = 0.004, p = 0.002, respectively), with no statistical superiority (Delong test, p = 0.82). Five‐year mortality was 52% for PPMM and 51% for PPMP. Severe‐PPMM and severe‐PPMP were not significantly associated to increased mortality when compared to the absence of PPMM (50% vs. 57% survival; HR 1.76, p = 0.221) or PPMP (69% vs. 58% survival; HR 0.81, p = 0.713), respectively. Conclusions: In this single healthcare system experience, neither measured PPM nor predicted PPM were predictive of 5‐year mortality in patients undergoing ViV‐TAVI.
- 8 February 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 107 (5) , 1484-1493
Five‐Year Outcomes of Measured and Predicted Prosthesis‐Patient Mismatch Following Valve‐in‐Valve Transcatheter Aortic Valve Implantation
Background: This study's objective was to investigate the incidence and long‐term outcomes of measured (PPM M ) and predicted (PPM P ) prosthesis‐patient mismatch in patients undergoing valve‐in‐valve (ViV) transcatheter aortic valve implantation (TAVI). Aims: To assess the outcomes of predicted and measured PPM in patients undergoing ViV TAVI. Methods: This retrospective, multicenter analysis included patients who underwent ViV TAVI at the Baylor Scott & White Health‐Care System between 2012 and 2021. Effective orifice area (EOA) was measured at discharge using transthoracic echocardiography and indexed to body surface area (EOAi), and predicted EOAi was derived from published reference values according to valve type and size. PPM was classified using standard EOAi cutoff values and subsequently reclassified using obesity‐adjusted EOAi thresholds for patients with body mass index ≥ 30 kg/m². Results: A total of 162 patients treated with ViV‐TAVI were analyzed: 64.8% were male, 34% had a BMI ≥ 30kg/m², and the median age was 77 [69.2; 84.0] years. The median STS risk score was 6.3 [3.5; 9.65] %. TAVI was performed trans‐femorally in 95.7%, using balloon‐expandable (52.5%) and self‐expanding (47.5%) devices. The incidence of severe PPMP was significantly lower than that of severe PPMM, both before (14.8% vs. 28.4%, p = 0.005) and after adjusting for BMI (11.1% vs. 24.7%, p = 0.002). Both severe PPMP and PPMM predicted high residual pressure gradient (≥ 20mmHg) ( p = 0.004, p = 0.002, respectively), with no statistical superiority (Delong test, p = 0.82). Five‐year mortality was 52% for PPMM and 51% for PPMP. Severe‐PPMM and severe‐PPMP were not significantly associated to increased mortality when compared to the absence of PPMM (50% vs. 57% survival; HR 1.76, p = 0.221) or PPMP (69% vs. 58% survival; HR 0.81, p = 0.713), respectively. Conclusions: In this single healthcare system experience, neither measured PPM nor predicted PPM were predictive of 5‐year mortality in patients undergoing ViV‐TAVI.
- Open Access
- 11 November 2025
- Published by Elsevier in Structural Heart
- Vol. 10 (1)
Impact of Measured and Predicted Patient–Prosthesis Mismatch on Quality of Life Following Transcatheter Aortic Valve Implantation
- 11 November 2025
- Published by Elsevier in Structural Heart
- Vol. 10 (1)
Open AccessImpact of Measured and Predicted Patient–Prosthesis Mismatch on Quality of Life Following Transcatheter Aortic Valve Implantation
- Open Access
- 15 October 2025
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 4 (11) , 104012
Radial to Peripheral Intervention: A Paradigm Shift
- 15 October 2025
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 4 (11) , 104012
Open AccessRadial to Peripheral Intervention: A Paradigm Shift