Nandini Aggarwal
Research Subjects
Nandini Aggarwal has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Erik Meijering
School of Computer Science and Engineering, University of New South Wales, Sydney, Australia
2 shared publications - Ihuan Gunawan
School of Biomedical Sciences, Faculty of Medicine and Health, University of New South Wales, Sydney, NSW, Australia
2 shared publications - John George Lock
School of Biomedical Sciences, University of New South Wales
2 shared publications - Richard J. Marsh
Department of Physics and Astronomy, University College London, London WC1E 6BT, United Kingdom
2 shared publications - Siân Culley
University College London
2 shared publications - Susan Cox
Randall Centre for Cell & Molecular Biophysics, Faculty of Life Sciences & Medicine (S.C.), King’s College London, United Kingdom
2 shared publications
Latest Publications
- Open Access
Image quality metrics fail to accurately represent biological information in fluorescence microscopy
Image processing methods offer the potential to improve the quality of fluorescence microscopy data, allowing for image acquisition at lower, less phototoxic illumination doses. The training and evaluation of such methods is informed and driven by full-reference image quality metrics (IQMs); however, these metrics derive from applications to natural scene images, not fluorescence microscopy images. Here we investigate the response of IQMs to common properties of fluorescence microscopy data and whether IQMs are capable of reporting the biological information content of images. We find that IQM scores are biased by image content for both raw and processed microscopy data, and that improvements in IQM values reported after processing are not reliably correlated with performance in downstream analysis tasks. As common IQMs are unreliable proxies for guiding image processing developments in biological fluorescence microscopy, image processing performance should be benchmarked according to downstream analysis success.
Open AccessImage quality metrics fail to accurately represent biological information in fluorescence microscopy
Image processing methods offer the potential to improve the quality of fluorescence microscopy data, allowing for image acquisition at lower, less phototoxic illumination doses. The training and evaluation of such methods is informed and driven by full-reference image quality metrics (IQMs); however, these metrics derive from applications to natural scene images, not fluorescence microscopy images. Here we investigate the response of IQMs to common properties of fluorescence microscopy data and whether IQMs are capable of reporting the biological information content of images. We find that IQM scores are biased by image content for both raw and processed microscopy data, and that improvements in IQM values reported after processing are not reliably correlated with performance in downstream analysis tasks. As common IQMs are unreliable proxies for guiding image processing developments in biological fluorescence microscopy, image processing performance should be benchmarked according to downstream analysis success.
- 5 August 2025
- Published by EMBL-EBI
The effect of image acquisition settings and image processing on fluorescence microscopy data and downstream analysis
BioStudies – one package for all the data supporting a study
- 5 August 2025
- Published by EMBL-EBI
The effect of image acquisition settings and image processing on fluorescence microscopy data and downstream analysis
BioStudies – one package for all the data supporting a study