ACAkash Chandra

Akash Chandra

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Akash Chandra has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Multitask Learning Framework for Elasticity and Viscosity Image Reconstruction in Ultrasound Viscoelastography

    by Phidakordor Sahshong, Anusua Das, Akash Chandra, Guy Cloutier, Karla P. Mercado-Shekhar, Manish Bhatt

    Soft tissues are viscoelastic in nature, and shear wave viscoelastography has emerged as an effective tool for differentiating healthy and diseased tissues by assessing their viscoelastic properties. This study presents a noise-aware multitask deep learning framework that simultaneously reconstructs tissue elasticity and viscosity maps. The proposed unified model directly estimates viscoelastic parameters from noisy shear-wave data, eliminating the need for explicit shear wave attenuation measurements and improving robustness to noise. The framework was trained on 1,000 velocity field datasets generated from numerical simulations, and validated across numerical simulations, tissue-mimicking phantoms, and in vivo duck liver datasets. Results demonstrated high fidelity in reconstruction accuracy, with strong agreement with ground truth in simulations and phantoms. In simulated phantoms where ground truth was available, the root mean square error for viscosity across samples was 0.128 (95% CI: 0.105–0.150) and for elasticity was 2.363 (95% CI: 2.157–2.573), and the structural similarity index was more than 0.96. In four in vivo duck liver datasets, elasticity values ranged from 11.50 ± 6.32 to 25.50 ± 17.16 kPa and viscosity ranged from 0.85 ± 0.46 to 1.8 ± 0.37 Pa·s. The denoising module improved the signal-to-noise ratio up to threefold and enabled reliable performance even in low-SNR conditions. The framework enables rapid, noninvasive viscoelastic imaging and establishes a foundation for future diagnostic tools that go beyond stiffness-based assessments.

  • Ultrasound Shear Wave Attenuation Estimates are Sensitive to In situ Fluid Content: In vitro and Ex vivo Studies

    by Sapna R. Bisht, Akash Chandra, Bhanu Prasad Marri, Jagruti M. Patil, Karla P. Mercado-Shekhar

    In shear wave elastography, viscoelastic properties of tissues can be estimated by fitting a rheological model to the phase velocity dispersion curve. However, there is a lack of consensus on the model that best represents tissue behavior. Model-free elastography approaches based on shear wave attenuation (SWA) and dispersion slope analysis have been reported previously. This study evaluated the ability of SWA and dispersion slope analysis to assess fluid content in situ using viscoelastic phantoms and ex vivo chicken breast. Model-free parameters were estimated in viscoelastic phantoms (with fluid percentages ranging from 72.6% to 79.9%, and pre- and post-compression by 10%) and ex vivo chicken breast samples pre- and post-hydration. Estimates of SWA were computed using the frequency-shift (FS) and the attenuation measuring shear wave elastography (AMUSE) methods. Dispersion slopes were computed from the phase velocity dispersion curves. The SWA coefficient estimates were strongly correlated with the fluid percentages in phantoms ( r = 0.86 and 0.92 for FS and AMUSE methods, respectively, p < 0.001). However, no trends were observed for dispersion slope estimates ( r = −0.73, p < 0.001). Thus, SWA was found to be a more sensitive parameter than the dispersion slope for differentiating phantoms with a range of in situ fluid content. Additionally, when phantoms were subjected to compression, SWA was sensitive to changes in compression-induced fluid variations in situ ( p < 0.05), but dispersion slope showed no such trends ( p = 0.12). The SWA estimates of ex vivo samples significantly increased post-hydration using both methods ( p < 0.05), while the dispersion slope decreased. The findings of this study demonstrate that SWA is sensitive to fluid content in situ, which motivates its further development as a marker to assess pathological conditions.

  • Modified Power Law Dispersion Model for Shear Waves in Soft Tissues

    by Anusua Das, Phidakordor Sahshong, Akash Chandra, Karla P. Mercado-Shekhar, Manish Bhatt

    Biological tissues display frequency-dependent non-linear dispersion in shear wave dispersion imaging. The dispersive behavior is due to the viscosity of soft tissues and may be correlated with tissue pathology. This study presents an empirically modified power law dispersion model that incorporates tissue nonlinearity and improves the dispersion modeling in shear wave elastography across an extended frequency bandwidth. The model was validated using numerically simulated phantoms, synthetic phantoms, and ex vivo goat muscle and liver tissues. The results demonstrate a higher goodness of fit compared to conventional models, including the Kelvin–Voigt, linear, and power-law dispersion models. Shear wave phase velocity, dispersion, and concavity maps are reconstructed in phantoms and ex vivo tissue samples. Quantitative values of dispersion are obtained as 1.55 ± 0.67 m/s/100 Hz and 1.68 ± 0.38 m/s/100 Hz in CIRS and PVA phantoms, respectively, and 3.16 ± 0.89 m/s/100 Hz and 1.44 ± 0.58 m/s/100 Hz in ex vivo goat muscle and liver tissues, respectively. The corresponding values of concavity are 4.12±2.11 m/s/kHz and 4.11±0.92 m/s/kHz in CIRS and PVA phantoms, respectively, and 6.52±2.71 m/s/kHz and 3.53±1.72 m/s/kHz in ex vivo goat muscle and liver tissues, respectively.