IHIsmail Hossain

Ismail Hossain

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ismail Hossain has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A blockchain-secured 6G smartgrid framework for resilient renewable energy integration and intelligent anomaly detection

    by Ismail Hossain, Abu Shufian, Morium Akter Munny, Nowshad Amin, Rayan Hamza Alsisi

    The integration of intermittent renewable energy into smart grids introduces critical vulnerabilities in security, transparency, and real-time resilience. This paper presents a novel blockchain-secured 6G Smart grid framework that synergistically integrates sixth generation (6G) ultra-reliable low-latency communication (URLLC), distributed ledger technology, and ensemble machine learning to establish a secure, scalable, and intelligent energy ecosystem. The proposed architecture leverages adaptive 6G network slicing to support differentiated services-including peer-to-peer energy trading, grid control, and cybersecurity monitoring-while ensuring sub-30 ms latency and robust connectivity. A permission blockchain layer provides decentralized trust, immutability, and automated transaction validation via formally verified smart contracts. An ensemble learning model combining XGBoost, Random Forest, and LightGBM enables real-time multi-dimensional anomaly detection across energy, network, and transaction layers. The framework is evaluated using a synthetically generated dataset of 5000 hourly records encompassing energy generation, consumption, 6G network performance, and blockchain transactions. Experimental results demonstrate a blockchain transaction success rate of 95.16% and sustained network latency below 30 ms across all slices, even under cyberattack conditions. Reported using class-based anomaly-detection metrics, the model achieves a Recall of 0.93 and F1-score of 0.97 for the anomaly class, and a Recall of 1.00 and F1-score of 0.99 for the normal class, with an overall accuracy of 0.98. The proposed system provides a foundational architecture for resilient, autonomous, and secure renewable energy management in next generation decentralized smart grids.


  • Open Access

    Enhancing stability in renewable energy transmission using multi-terminal HVDC systems with grid-forming controls for offshore and onshore wind integration

    by Abu Shufian, Ismail Hossain, Hasanur Zaman Anonto, Ahmed Intekhab Rohan

    This paper presents a thorough analysis of two-terminal VSC-HVDC links, and the effects of isolated faults have been extensively studied in multi-terminal HVDC (MTHVDC) networks systems that would enable the interconnection of substantial offshore wind farm energy resources to onshore power systems with emphasis on dynamic transmission performance during different fault and perturbation scenarios. The performance of the system was evaluated against three important scenarios: transient faults, sudden load drops, and wind speed changes. The work presented a comparative analysis of Grid-Following (GFL) and Grid-Forming (GFM) control strategies with a focus on their provisions in offering compliance with grid code requirements, particularly, in faults ride-through (FRT) performance. Transient stability and grid compliance has been performed through the study to take results as the GFM controller performance has been better as compared to GFL controller in the study. The GFM controller recovered more rapidly than its GFL counterpart, achieving voltage stability within 0.5 s and frequency stability within 0.6 s when subjected to fault and load disturbances, versus 1.2 s and 1.8 s for the GFL controller’s voltage and frequency, respectively. The difference in voltage and frequency deviation between the GFL and the GFM system was less than ± 4% and less than ± 0.3 Hz respectively, further verifying that the GFM system far outperformed the GFL system, which demonstrated a voltage stability of ±18% and a frequency stability of ± 0.9 Hz under load disturbance. The results demonstrated the GFM controller’s capability to stabilize power systems rapidly and fulfill grid code requirements even in the presence of compounded disturbances. The virtual inertia and dynamic dampness provided by GFM controller make the system resilient against fluctuations in both wind generation and grid faults. The results highlight the value of GFM-based MTHVDC systems as a dependable option for integrating offshore wind energy into the grid, creating a system with superior stability and efficiency in future large-scale renewable energy systems.


  • Anomaly Detection in DC Distribution Systems: A Wavelet and Autoencoder-Based Method

    by Ismail Hossain, Mohammed Asaf-Ud-Doulah, Hasanur Zaman Anonto, Mehrab Islam Omi, Abu Shufian, Khandoker Mainul Islam

  • Hybrid CNN-Bidirectional LSTM Networks for Advanced ECG Signal Classification and Arrhythmia Fibrillation Detection

    by Ismail Hossain, Sarowar Hossain, Farden Alamin, Al Shahriar Zishan, Rafsan Jany, Abu Shufian

  • Open Access

    Enhancing microgrid resilience through integrated grid-forming and grid-following inverter strategies for solar PV battery control and fault ride-through

    by Ismail Hossain, Hasanur Zaman Anonto, Abu Shufian, Bishwajit Banik Pathik, Mohammad Abdul Mannan, Abdur Rashid, Parag Biswas

    This study investigates the integration of a Grid-Forming (GFM) Battery Energy Storage System (BESS) to enhance the stability of microgrids in the presence of high renewable energy penetration. The proposed GFM inverter, combined with BESS, significantly improves fault resiliency and oscillation stability compared to traditional Grid-Following (GFL) inverters. The GFM inverter enables fault ride-through (FRT), maintaining operational stability during grid faults with voltage recovery within 300 ms and frequency deviations limited to ± 0.5 Hz. The GFM-controlled system stabilized within 1 s during a 50% solar irradiance drop, supplying reactive power and inertial support, while the GFL inverter struggled to stabilize under a Short Circuit Ratio (SCR) of 0.423, leading to large voltage and frequency deviations. Additionally, during a 46% increase in load demand, the BESS under GFM control immediately compensated for the real power imbalance, demonstrating the crucial role of energy storage in improving microgrid stability. In contrast, the GFL inverter failed to stabilize under similar conditions. Simulation results using MATLAB/Simulink confirmed that the GFM inverter restored microgrid stability more effectively, with faster fault recovery and improved voltage regulation compared to GFL inverters. The implementation of an Energy Management System (EMS) optimized power flow between the PV, BESS, and grid, enhancing system efficiency and participation in energy markets. These findings validate the potential of GFM inverters, supported by advanced control strategies, to provide reliable, efficient, and sustainable microgrid operations, indicating their practical viability in future energy networks.


  • Open Access

    Intelligent fault diagnosis in rolling element bearings: Combining envelope spectrum and spectral kurtosis for enhanced detection

    by Ahmed Intekhab Rohan, Tasfia Akter Ridita, Hasanur Zaman Anonto, Ismail Hossain, Abu Shufian, Saidur Rashid Mahin, Ashikul Islam