Bahar Selenay Bulut
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bahar Selenay Bulut has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Aysun Uz
Department of Anatomy, School of Medicine, Ankara University, Ankara, Türkiye
3 shared publications - Mehmet Yılmaz
Department of Anatomy, Ankara University Faculty of Medicine, Ankara, Turkey
2 shared publications - Trifon Totlis
Thessaloniki Minimally Invasive (The‐MIS) Orthopaedic Center St. Luke's Hospital Thessaloniki Greece
2 shared publications - George Triantafyllou
VARIANTIS Research Laboratory, Department of Clinical Anatomy, Mazovian University in Płock, 09-402 Plock, Poland
1 shared publication - Murat Doğuş Günel
Department of Biostatistics, School of Medicine, Ankara University, Ankara, Turkey
1 shared publication - Niymet Pelin Cavdar Yilmaz
Department of Anatomy, School of Medicine, Ankara University, Sihhiye, Ankara, Turkey
1 shared publication
Latest Publications
- Open Access
Anatomical Study of the Clavicle: Implications for Clinical Practice
Background/Objectives: The aim of this study is to describe clavicular morphometric parameters and key bony landmarks relevant to plate-and-screw fixation and ligamentous reconstruction procedures. Methods: Morphometric measurements were performed on 179 adult human clavicles: 84 right and 95 left. Linear measurements were obtained using a Mitutoyo digital caliper (0.01 mm precision). Angular measurements were conducted using ImageJ software (LOCI, University of Wisconsin, Madison, USA). Results: The mean distance between the sternal articular surface and the midpoint of the sternoclavicular curvature was 49.23 ± 8.86 mm. The mean distance between the midpoints of the sternoclavicular and acromioclavicular curvatures was 65.16 ± 12.17 mm. The mean distance between the midpoint of the acromioclavicular curvature and the acromial articular surface was 41.58 ± 4.85 mm. The mean sternoclavicular angle was 153.31 ± 9.53° and the mean acromioclavicular angle was 119.95 ± 10.92°. The average thickness of the narrowest middle part of the clavicle was 11.61 ± 1.77 mm. The mean projection distance from the middle part of the clavicle to the most prominent point of the conoid tubercle was 43.81 ± 6.33 mm. The distances from the middle part of the clavicle to the medial trapezoid line and to the lateral impression of the costoclavicular ligament were 50.10 ± 6.31 mm and 42.29 ± 5.88 mm, respectively. The mean projected clavicular length was 142.76 ± 12.29 mm. Conclusions: In conclusion, these findings offer an anatomical reference that may assist radiological evaluation of clavicular shortening and support orthopaedic surgeons in implant selection and planning of ligament reconstruction procedures.
Open AccessAnatomical Study of the Clavicle: Implications for Clinical Practice
Background/Objectives: The aim of this study is to describe clavicular morphometric parameters and key bony landmarks relevant to plate-and-screw fixation and ligamentous reconstruction procedures. Methods: Morphometric measurements were performed on 179 adult human clavicles: 84 right and 95 left. Linear measurements were obtained using a Mitutoyo digital caliper (0.01 mm precision). Angular measurements were conducted using ImageJ software (LOCI, University of Wisconsin, Madison, USA). Results: The mean distance between the sternal articular surface and the midpoint of the sternoclavicular curvature was 49.23 ± 8.86 mm. The mean distance between the midpoints of the sternoclavicular and acromioclavicular curvatures was 65.16 ± 12.17 mm. The mean distance between the midpoint of the acromioclavicular curvature and the acromial articular surface was 41.58 ± 4.85 mm. The mean sternoclavicular angle was 153.31 ± 9.53° and the mean acromioclavicular angle was 119.95 ± 10.92°. The average thickness of the narrowest middle part of the clavicle was 11.61 ± 1.77 mm. The mean projection distance from the middle part of the clavicle to the most prominent point of the conoid tubercle was 43.81 ± 6.33 mm. The distances from the middle part of the clavicle to the medial trapezoid line and to the lateral impression of the costoclavicular ligament were 50.10 ± 6.31 mm and 42.29 ± 5.88 mm, respectively. The mean projected clavicular length was 142.76 ± 12.29 mm. Conclusions: In conclusion, these findings offer an anatomical reference that may assist radiological evaluation of clavicular shortening and support orthopaedic surgeons in implant selection and planning of ligament reconstruction procedures.
- 22 September 2025
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 47 (1) , 1-6
Scaphoid bone morphometry and nutrient foramina: anatomical study and clinical implications
Purpose The aim of the current study is to reveal the morphological features and nutrient foramina distribution of scaphoid bone in a Turkish population, which may be helpful to diagnosis and surgical treatment of scaphoid fractures. Methods One hundred and two (51 right, 51 left) dry scaphoid bone were measured. The following measurements were performed: length, width, area of articular surfaces, mid-peripheral width, number of posterior grooves, width and length of the grooves, length of the scaphoid tubercle and number of nutrient foramina, proximal or distal location of these foramina, and distance to the transverse midline were measured. Circumferential measurements were made using a surgical tape measure, morphometric measurements using a digital caliper and area measurements using the ImageJ program (LOCI, University of Wisconsin, Madison, USA). Results The length and width of the scaphoid bone are 25.57 ± 2.17 mm and 10.07 ± 1.25 mm, and the midline circumference is 34.85 ± 3.92 mm. In 41 bones a second posterior groove (sulcus) was found. Length and width of the main posterior groove was 19.43 ± 3.14 mm and 2.17 ± 0.67 mm respectively, number of nutrient foramen was 6 ± 2, length of scaphoid tubercle was 12.03 ± 1.78 mm. Overall, 341 nutrient foramen (215 dorsal, 126 palmar) were identified. The distance of the proximal nutrient foramen to the midline was 3.41 ± 2.37 mm and the corresponding distance of the distal nutrient foramen was 4.63 ± 2.72 mm. Conclusion This study revealed the scaphoid bone morphology, morphometry and nutrient foramina number and location in the Turkish population. These findings are important for orthopaedic surgeons during scaphoid bone surgery for fractures or pseudarthrosis.
- 22 September 2025
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 47 (1) , 1-6
Scaphoid bone morphometry and nutrient foramina: anatomical study and clinical implications
Purpose The aim of the current study is to reveal the morphological features and nutrient foramina distribution of scaphoid bone in a Turkish population, which may be helpful to diagnosis and surgical treatment of scaphoid fractures. Methods One hundred and two (51 right, 51 left) dry scaphoid bone were measured. The following measurements were performed: length, width, area of articular surfaces, mid-peripheral width, number of posterior grooves, width and length of the grooves, length of the scaphoid tubercle and number of nutrient foramina, proximal or distal location of these foramina, and distance to the transverse midline were measured. Circumferential measurements were made using a surgical tape measure, morphometric measurements using a digital caliper and area measurements using the ImageJ program (LOCI, University of Wisconsin, Madison, USA). Results The length and width of the scaphoid bone are 25.57 ± 2.17 mm and 10.07 ± 1.25 mm, and the midline circumference is 34.85 ± 3.92 mm. In 41 bones a second posterior groove (sulcus) was found. Length and width of the main posterior groove was 19.43 ± 3.14 mm and 2.17 ± 0.67 mm respectively, number of nutrient foramen was 6 ± 2, length of scaphoid tubercle was 12.03 ± 1.78 mm. Overall, 341 nutrient foramen (215 dorsal, 126 palmar) were identified. The distance of the proximal nutrient foramen to the midline was 3.41 ± 2.37 mm and the corresponding distance of the distal nutrient foramen was 4.63 ± 2.72 mm. Conclusion This study revealed the scaphoid bone morphology, morphometry and nutrient foramina number and location in the Turkish population. These findings are important for orthopaedic surgeons during scaphoid bone surgery for fractures or pseudarthrosis.
- 5 August 2025
- Published by Springer Nature in Bratislava Medical Journal
- Vol. 126 (10) , 2514-2521
Where is The Main Trunk of Great Auricular Nerve?
- 5 August 2025
- Published by Springer Nature in Bratislava Medical Journal
- Vol. 126 (10) , 2514-2521
Where is The Main Trunk of Great Auricular Nerve?