Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Stefano Lissandron has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Temperature Compensation for Chromatic Stability of RGBW LEDs in Automotive Interior Lighting

    by Dennis Rapaccini, Laura Falaschetti, Stefano Lissandron, Massimo Conti, Simone Orcioni, Andrea Morici

    Automotive interior lighting has progressed from basic functional illumination to sophisticated aesthetic systems emphasizing chromatic stability under thermal variations. This study enhances an RGB temperature compensation algorithm for LEDs, extending it to an RGBW solution. While several approaches for LED temperature compensation have been proposed in the literature, none have addressed a complete RGBW solution where the white channel is derived and actively adjusted on thermal variations. This research aims to fill this gap by extending an RGB algorithm to RGBW and validating it under realistic automotive conditions. While the proposed compensation strategies are general and may be applied to other LED systems, the automotive interior lighting domain has been selected as a representative case study because it combines stringent chromatic stability requirements (Δu′v′≤0.01) and high industrial relevance. Leveraging Infineon’s LITIX™ LED drivers, experimental results show that the algorithm maintains chromatic stability with deviations below Δu′v′=0.00562 in RGB mode and Δu′v′=0.0067 in RGBW mode across the tested temperature range. The addition of the white channel improves the color rendering index (CRI) by up to 58.9 points (from 19.7 to 78.6) while preserving color quality. Compared to previous works limited to RGB systems, our approach provides the first practical RGBW compensation algorithm experimentally validated under realistic automotive conditions.


  • Analysis of $\Delta P -\Delta Q$ Area of Uncontrolled Islanding in Low-Voltage Grids With PV Generators

    by Riccardo Sgarbossa, Stefano Lissandron, Paolo Mattavelli, Roberto Turri, Alberto Cerretti

    The large penetration of distributed energy resources (DERs), especially photovoltaic (PV), in low-voltage (LV) distribution grids has raised the concern of unintentional islanding operations. The probability of unintentional islanding is increased mainly due to the newly introduced standards with extended frequency and voltage thresholds and the additional grid support functions, such as active and reactive power regulation using P/f and Q/V droop characteristics. Moreover, islanding operation due to faulty events at the medium-voltage (MV) distribution level may be dangerous in the presence of automatic reclosing procedure leading to out-of-phase reconnections. In this paper, an analysis of this phenomena is provided using simplified generator and load models. Simulation results based on MATLAB and DIgSILENT tools on a simplified LV distribution network are reported together with experimental results on a lab-scale prototype.


  • Experimental Validation for Impedance-Based Small-Signal Stability Analysis of Single-Phase Interconnected Power Systems With Grid-Feeding Inverters

    by Stefano Lissandron, Luca Dalla Santa, Paolo Mattavelli, Bo Wen

    The interactions of more and more power electronics-interfaced power systems can worsen the power quality and the system stability in distribution networks. System stability can be addressed by analyzing the source and load impedances at the interaction section, and well-established approaches exist for dc and three-phase ac networks. Some papers also focused on single-phase ac systems, whose study is generally more difficult due to their time-varying characteristics. Similar to the approaches based on dq rotating frame impedances, this paper focuses on single-phase systems using the dynamic phasor approach to determine the 2-D source and load impedances. The system stability is then evaluated using the generalized Nyquist stability criterion. As an example of application, a single-phase ac system that includes a current-controlled inverter synchronized to the grid through a phase-locked loop is proposed. Experimental validations are provided herein to verify the feasibility of this approach and the stability criteria based on the 2-D source and load impedances in the single-phase systems.


  • ΔP — ΔQ area assessment of temporary unintentional islanding with P/f and Q/V droop controlled PV generators in distribution networks

    by Stefano Lissandron, Riccardo Sgarbossa, Luca Dalla Santa, Paolo Mattavelli, Roberto Turri, Alberto Cerretti

    Distributed Generation in Low Voltage grids has raised the concern of unintentional islanding and its probability has increased due to the newly introduced standards for generators, which in particular impose wider frequency and voltage ranges and active and reactive power support capabilities using of P/f and Q/V droop characteristics. Anti-islanding protections that each inverter is equipped with, may fail to detect the grid transition and so uncontrolled islanding operation may appear. This operation may be dangerous especially in presence of automatic reclosing procedure, because of possible out of phase reconnections. In this paper, the temporary unintentional islanding operation (e.g. below 600 ms) is studied considering the effects of P/f and Q/V droop characteristics of generators and their response times. A potential increase of such phenomenon will be shown with simulations and experimental results.


  • Experimental verification of impedance-based small-signal stability analysis for single-phase interconnected power systems

    by Stefano Lissandron, Luca Dalla Santa, Paolo Mattavelli, Bo Wen

    The interactions of more and more power electronics-interfaced power systems can worsen the power quality and the system stability in distribution networks. System stability can be addressed analyzing the source and load impedances at the interaction section and well-established approaches exist for DC and three-phase AC networks. Some papers focus also on single-phase AC systems, whose study is generally more difficult due to their nonlinear and time-varying characteristics. One viable solution to address this issue is the use of equivalent dq rotating reference frame even for single-phase system so as to identify a steady-state operating condition. This paper describes an approach to identify a steady-state operation in single-phase AC models to enable an impedance-based small-signal analysis to infer the stability of the system. Experimental validations are provided herein to verify the stability criteria based on the source and load impedances.


  • Validation of impedance-based small-signal stability analysis for single-phase grid-feeding inverters with PLL

    by Stefano Lissandron, Luca Dalla Santa, Paolo Mattavelli, Bo Wen

    The interactions of more and more power electronics-interfaced power systems can worsen the power quality and the system stability in distribution networks. System stability can be addressed analyzing the source and load impedances at the interaction section and well-established approaches exist for DC and three-phase AC networks. Some papers focused also on single-phase AC systems, whose study is generally more difficult due to their nonlinear and time-varying characteristics. One viable solution to address this issue is the use of equivalent dq rotating reference frame even for single phase system so as to identify a steady-state operating condition. This paper uses this approach and proposes the small-signal analysis of a single-phase AC system that includes a current-controlled inverter synchronized to the grid via a Phase-Locked Loop (PLL). Experimental validations are provided herein to asses the feasibility of this approach and to verify the stability criteria based on the source and load impedances.


  • Impact of non-simultaneous P/f and Q/V grid code requirements on PV inverters on unintentional islanding operation in distribution network

    by Stefano Lissandron, Riccardo Sgarbossa, Luca Dalla Santa, Paolo Mattavelli, Roberto Turri, Alberto Cerretti

    The analysis of unintentional islanding in distribution grids with a large penetration of renewable energy sources is of increasing interest due to the recently introduced requirements of P/f and Q/V supporting capabilities of Distributed Energy Resources (DERs) and the wider frequency and voltage ranges, DERs should be able to operate with, before protection tripping. DER anti-islanding protections, if present, may fail to detect this grid transition and so uncontrolled islanding operation may appear. Since this operating mode may be dangerous for the electric network operation and may cause damages for the grid equipment, in this paper the increase of its risk due to P/f and Q/V droop characteristics of generators is addressed. Analytic results are initially derived for the steady-state unintentional islanding operation and then they are validated on a laboratory-scale grid setup. The proposed investigation will show that the risk of permanent unintentional islanding increases introducing P/f or Q/V droop regulation and that such risk is maximum including both the P/f and Q/V droop regulations, rather than only one of them.


  • A controller for the smooth transition from grid-connected to autonomous operation mode

    by Stefano Lissandron, Paolo Mattavelli

    In this paper, a local controller for inverter of Distributed Energy Resources (DERs) is presented to manage a microgrid during grid-connected and autonomous operation modes and also during the transition. It is based on the P-f and Q-V droop control: during grid-connected operation, the controller tracks active and reactive power references and, during islanded mode, it exploits the droop control properties to share the load among the DERs. The peculiarity of this regulator is that it does not need to identify the particular operation mode and so a smooth transition from grid-connected to islanded mode can be achieved with no communication within the power grid or among the disconnecting switch and DERs. This controller has been implemented in a FPGA platform and its operation has been tested via an Hardware-In-the-Loop (HIL) and Real-Time (RT) simulation approach.


  • Analysis of ΔP-ΔQ area of uncontrolled islanding in low voltage grids with PV generators

    by Riccardo Sgarbossa, Stefano Lissandron, Paolo Mattavelli, Roberto Turri, Alberto Cerretti

    The large penetration of Distributed Energy Resources (DERs), especially PhotoVoltaic (PV), in Low Voltage (LV) distribution grids has raised the concern of unintentional islanding operations. The probability of unintentional islanding is increased due to the newly introduced standards with extended frequency and voltage thresholds and additional grid support functions, such as active and reactive power regulation using P/f and Q/V droop characteristics, which can make ineffective the anti-islanding provisions each PV is equipped with. Moreover, islanding operation due to faulty events at the Medium Voltage (MV) distribution level may be dangerous in presence of automatic reclosing procedure leading to out of phase reconnections. In this paper, an analysis of this phenomena is provided using a simplified characterization of the generators and the loads. Simulation results based on Matlab and DIgSILENT tools on a simplified LV distribution network are reported together with preliminary experimental results on a lab-scale prototype.


  • Analysis of load-induced unintentional islanding in Low Voltage grids with PV generators

    by Riccardo Sgarbossa, Stefano Lissandron, Paolo Mattavelli, Roberto Turri, Alberto Cerretti

    The interest of unintentional islanding operation has recently grown in Low Voltage (LV) distribution grids because of the large penetration of Distributed Energy Resources (DERs), especially the ones based on the PhotoVoltaic (PV) energy source. The probability of unintentional islanding is increased also due to the newly introduced standards with extended frequency and voltage limits before the PV protection trips and due to the large number of PV generators, which can make ineffective the anti-islanding provisions each PV is equipped with. Moreover, interconnection standards of DERs require some additional grid support functions, such as active and reactive power regulation using P/f and Q/V droop characteristics, which can further increase the probability of unintentional islanding. In this paper, an analysis of this phenomena is provided using a simplified static and dynamic characterization of the generators and the loads. Simulation results based on Matlab and DIgSILENT tools on a simplified LV distribution network are reported together with preliminary experimental results on a lab-scale prototype.